BEAUPORT

BEAUPORT is a 1993 passenger vessel (inspected). The Coast Guard has recorded 70 inspections since 1993, most recently in May 2026, along with 151 deficiencies and 1 casualty investigation in 2012.

Records from 1993 to 2026. Most recent: inspection, 19 May 2026.

Built
1993
Last inspected
19 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ9959
390289
Flag
UNITED STATES
368031080
Maury page id
psix-390289

Inspections, by type

…with no type recorded12
Years with a record 33 calendar years (1993–2026)
The 70 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)124.0 ft × 30.0 ft × 10.8 ft
Registered tonnagegross 93 / net 63
ITC dimensions (L × B × D)124.0 ft × 30.0 ft × 10.8 ft
ITC tonnagegross 620 / net 221
BuilderFREEPORT SHIPBUILDING AND MARINE REPAIR · FREEPORT, FL, UNITED STATES · built 1993
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGLOUCESTER, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 28 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it63 - Regulatory (Subpart C or D), Net Ton
221 - Convention (Subpart B), Net Ton
308 - Displacement, Ton
93 - Regulatory (Subpart C or D), Gross Ton
620 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ9959MMSI 368031080 · active · compulsorily equipped · granted 4 April 2018, expires 4 April 2028
WDH2375MMSI 367596930 · expired · compulsorily equipped · granted 28 November 2013, cancelled 3 February 2024 · licensed under a name not among this hull’s recorded names (not shown)
WBZ4358MMSI 367373830 · expired · compulsorily equipped · granted 20 August 2008, cancelled 3 November 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 70

19 May 2026 Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8349878
6 November 2025 Drydock Exam · Vessel Attendance
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8262250
29 May 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8133168
4 February 2025 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8075019
10 October 2024 Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8016672
17 June 2024 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7908631
28 February 2024 Damage Survey · Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7871671
29 November 2023 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7829720
31 May 2023 In-Service Inspection · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7668602
24 June 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7465582
15 November 2021 Deficiency Check · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7351141
16 July 2021 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7258188
9 October 2020 Internal Structural Exam · Drydock Extension
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7073817
15 September 2020 In-Service Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7058529
13 November 2019 DAPI Audit · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6855895
5 November 2019 Annual Inspection · Deficiency Check · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6848454
28 November 2018 Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6586494
5 November 2018 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6573109
30 March 2018 Deficiency Check · DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6384790
2 March 2017 Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6097126
15 November 2016 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6042925
5 July 2016 Damage Survey · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5931488
5 July 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5933819
18 November 2015 Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5766671
24 July 2015 MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5198714
21 August 2014 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4961757
16 July 2012 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4380541
5 January 2011 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3917605
20 September 2010 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3853315
21 January 2009 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3393790
7 October 2008 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3338140
17 July 2007 MTSA Verification
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3082564
16 July 2007 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2996837
27 February 2007 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2906476
10 October 2006 Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2798293
8 February 2006 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2581573
20 September 2005 MTSA Verification · Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2496848
23 May 2005 MTSA Verification
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2366308
17 February 2005 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2294235
12 October 2004 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2218851
10 June 2004 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2099427
30 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1972307
16 October 2003 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1930375
16 September 2003 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1905377
25 February 2003 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1749683
21 February 2003 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1755344
18 July 2002 Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1648132
28 September 2001 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1382401
15 June 2001 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 59262
15 May 2001 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 693798
14 April 2001 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 180771
14 April 2001 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 213158
11 April 2001 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1405205
29 September 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 822011
13 September 2000 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1391534
21 July 1999 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1437600
12 May 1999 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1436357
15 July 1998 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1396968
15 July 1997 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1435957
20 May 1997 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1394763
16 July 1996 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1453262
17 July 1995 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1412841
25 May 1995 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 878474
11 October 1994 Damage Survey · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1175746
8 October 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 153661
8 October 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 223393
19 July 1994 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1179212
1 October 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1470883
22 July 1993 Hull Examination · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1141999
13 July 1993 Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 843920

Deficiency record · 151

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 May 2026 Resolved
[Exhaust piping] must be gas tight throughout its length. A medium-sized leak of exhaust gas was found in the lazarette coming from the starboard engine's exhaust piping, leaking exhaust gas into the space. Additionally, the lazarette access hatch is inside the passenger accommodation space and is not fitted with a gas-tight seal. 46 CFR 182.15-20 (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 5 June 2026
Resolution: Operator fixed the exhaust leak
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 19 May 2026 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Electronic chart installed on board could not be confirmed compliant with RTCM 10900 standards. Paper charts on board were older than 6 months and therefore out of date. 46 CFR 121.420(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 5 June 2026
Resolution: Operator procured up to date chart
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 May 2026 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Sixty (60) life jackets were found to have deteriorated buoyant foam (45 from 2nd deck, 15 from 3rd deck). Vessel may not operate with more than 364 total passengers on board. 46 CFR 117.71(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 5 June 2026
Resolution: Operator procured required number of new life jackets.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 May 2026 Resolved
Each nozzle must be of a type approved in accordance with approval series 162.027. Fire nozzle on 2nd deck fire hose was not capable of producing a water spray pattern. 46 CFR 118.320(c)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 5 June 2026
Resolution: New fire nozzle installed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 19 May 2026 Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight. Plastic discharge piping from aft kitchenette attached to the starboard hull had a small opening allowing daylight through. 46 CFR 171.114(a)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 5 June 2026
Resolution: Operator installed new discharge line to fix the hole.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 19 May 2026 Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members. Both speakers on 3rd deck passenger deck were not operational. 46 CFR 121.610(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2026
Resolved 5 June 2026
Resolution: PA system is fully operational
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 May 2025 Resolved
An adult life jacket must be provided for each person carried on board a vessel. 127 adult life jackets were found in a damaged condition and removed from service. Replace life jackets removed from the vessel. Vessel is limited to a total maximum of 343 persons on board until appropriate number of life jackets are on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 24 June 2025
Resolution: Operator had procured 130 new lifejackets, labeled them and stowed them on the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 May 2025 Resolved
A door in a bulkhead required to be A-60 Class must be capable of meeting the requirements of an A-15 Class bulkhead. The door handles on the deck 03 stairtower doors were loose and not forming a fire boundary. Tighten/replace to the satisfaction of the Coast Guard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 24 June 2025
Resolution: Operator tightened the doorknobs.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 May 2025 Resolved
Waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Waste receptacles on the vessel are plastic combustible types. Replace waste receptacles with noncombustible ones.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 24 June 2025
Resolution: Operator replaced plastic waste recepticles with metal ones.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 May 2025 Resolved
Each distribution panel or switchboard must be totally enclosed. The engine room port distribution panel had a missing punch out circular plate on the side of the panel box. Replace missing punch out plate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 24 June 2025
Resolution: Operator installed a cover for the punch-out on the panel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 June 2024 Resolved
An adult life jacket must be provided for each person carried on board a vessel. MI observed 06 life jackets with failed inner foam material. Total Persons Allowed On Board is reduced to 464 until replacement lifejackets are onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2024
Resolution: Operator submitted objective evidence in the form of photographs showing new lifejackets had been procured and installed on the vessel.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 June 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. MI observed wastage in the aft support gussets on both rudderposts as well as on the 1st transverse frame, starboard side, aft of the forward bulkhead in way of the chine to inboard longitudinal frame. Operator to submit plan to repair prior to next credit hull inspection.
Action required: 705 - Other - as specified
Due 31 December 2025
Resolved 18 November 2025
Resolution: Operator replaced the gusset.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 June 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to: Minimize accidental personnel contact with energized parts. MI observed 04 openings inside distribution panel in galley and exposed wire ends in an overhead light in the galley.
Action required: 10 - Deficiency Rectified
Resolved 17 June 2024
Resolution: Operator installed breaker blanks in the distribution panel and installed a new light fixture in the galley.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 June 2024 Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. MI observed that the lifeline on 02 ringbuoys were deteriorated and breaking when flexed.
Action required: 10 - Deficiency Rectified
Resolved 17 June 2024
Resolution: Operator installed new lifelines on the ring buoys.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 June 2024 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. MI observed the portable light at the operating station had very weak batteries and there was no portable light outside the propulsion machinery space.
Action required: 10 - Deficiency Rectified
Resolved 17 June 2024
Resolution: Operator procured new portable lights.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 29 November 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Superstructure bulkhead bottom, at the aft port door-sill, found wasted through and open to the weather. Crop and renew to good steel, to the satisfaction of the attending Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 29 November 2023
Resolved 8 December 2023
Resolution: Insert repaired after failing NDT on 06Dec. Repairs made by O/O on 08Dec, passed NDT, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 24 June 2022 Resolved
The alcohol testing of each individual must be conducted within 2 hours of when the SMI occurs. Alcohol testing equipment was was expired. Obtain approved testing equipment and keep onboard at all times.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2022
Resolved 6 July 2022
Resolution: New test strips are now onboard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 June 2022 Resolved
Each distribution panel must be protected from falling debris and dripping/splashing water. The front cover hardware on the pilothouse was broken allowing foreign object and water ingress. Repair/replace junction box as necessary to keep debris/water out.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2022
Resolved 6 July 2022
Resolution: New cover was installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 July 2021 Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel operated without a valid COI.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 16 July 2021
Resolved 16 July 2021
Resolution: Completed COI inspection and issued valid COI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 November 2019 Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. The company has been enrolled in a non DOT drug testing program where results are not reviewed by a Medical Review Officer. Company must conduct pre-employment DOT drug testing for all employees who hold a safety sensitive position on the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 November 2019
Resolved 18 November 2019
Resolution: Company re-enrolled with Quest diagnostics in DOT program.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 November 2019 Resolved
The selection of crewmembers for random drug testing shall be made by a scientifically valid method, with each covered crewmember having an equal chance of being tested each time selections are made. Company is currently not using a scientifically valid method in selecting employees for random drug testing. Company shall use an approved method for selecting crewmembers for random drug testing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 November 2019
Resolved 18 November 2019
Resolution: Company is now utilizing a proper method for random drug testing selection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 November 2019 Resolved
The employer shall provide an Employee Assistance Program (EAP) for all crewmembers. Specifically, an EAP training program must be conducted for the employer’s crewmembers and supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. Company currently does not conduct EAP training with crewmembers or supervisors. Company shall complete at least 60 minutes of EAP training with supervisors and general training for all other crewmembers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 November 2019
Resolved 18 November 2019
Resolution: Company provided proof of EAP training for supervisors and all covered personnel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 November 2019 Resolved
Drug testing programs required by this part must be conducted in accordance with 49 CFR part 40, Procedures for Transportation Workplace Testing Programs. The company is not compliant with, specifically but not limited to part 16.201. **Must bring drug testing program into full compliance prior to carrying passengers**
Action required: 705 - Other - as specified
Resolved 18 November 2019
Resolution: DAPI AUDIT Conducted and complete
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 5 November 2019 Resolved
Decks of the ‘‘A’’ Class shall be so insulated with approved structural insulation, deck covering that the average temperatures on the unexposed side would not rise more than 250 °F. above the original temperature, nor would the temperature at any one point, including any joint, rise more than 325 °F. above the original temperature, within the time listed below: Class A–60, 60 minutes. If the pipe passes through an A-60 division, approved structural insulation should be applied to the pipe on the insulated side of the division for a distance of at least 300 mm (12 inches). The A-60 deck fire boundary located on the overhead within the engine room is missing A-60 insulation in two locations where pipe penetrations are located.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2019
Resolved 20 November 2019
Resolution: Recified deficiency
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 November 2019 Resolved
The Certificate of Inspection (COI) must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. Vessel has expired temporary COI posted in restricted pilot house on the navigation bridge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2019
Resolved 20 November 2019
Resolution: Recified deficiency
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 November 2019 Resolved
Charts and nautical publications. (a) As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; vessel has on board out dated paper charts (2009) & outdated electronic charts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2019
Resolved 20 November 2019
Resolution: Recified deficiency
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 5 November 2019 Resolved
Each hydrostatic release unit, other than a disposable unit, must be serviced within 12 months of its manufacture and within 12 months of each subsequent subsequent servicing. Each disposable hydrostatic release unit must be marked in clearly legible letters with an expiration date of two years after the date on which the unit is installed. EPIRB hydrostatic release unit is expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2019
Resolved 20 November 2019
Resolution: Recified deficiency
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 November 2019 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or equivalent contents. First Aid Kit contents are expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2019
Resolved 20 November 2019
Resolution: Recified deficiency
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 November 2019 Resolved
All microprocessor or computer based systems must meet the requirements of part 62 in subchapter F. Vessel operators could not provide Design Test Verification Procedures or any USCG review of installation.
Action required: 705 - Other - as specified
Due 5 May 2020
Resolved 14 October 2020
Resolution: Vessel developed and submitted plans. Tested locally. Approval letter recieved from MSC.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 November 2019 Resolved
Protect passengers, crew, and the vessel from electrical hazards, including fire, caused by or in electrical equipment, and electrical shock. The outside light on 3rd deck is not hardwired to the electrical system
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2019
Resolved 20 November 2019
Resolution: Recified deficiency
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 November 2019 Resolved
A vessel must comply with the applicable requirements as set forth in 47 CFR 80. FCC Safety Radio Certificate not on board vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2019
Resolved 20 November 2019
Resolution: Recified deficiency
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 28 November 2018 Resolved
Amp meter does not work. Provide working amp meter for generator distribution panel. 46 CFR 183.10-5(g)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2018
Resolution: Repaired inoperable amp meter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 28 November 2018 Resolved
Battery charger does not have an amp meter. Provide in line amp meter on battery charger. 46 CFR 183.05-20(f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2018
Resolution: Installed amp meter.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Other (MARPOL Annex VI)
Issued 28 November 2018 Resolved
Sewage discharge valve is not secured. Provide a method of securing overboard discharge.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2018
Resolution: Installed lock and chain on the overboard discharge valve.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 November 2018 Resolved
Life jacket donning placards are illegible on deck 2 forward, port & starboard. Provide legible life jacket donning placards.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2018
Resolution: Provided new life jacket donning instructions.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 November 2018 Resolved
Life ring located on deck 3 is worn and the light is incorrectly spliced together. Replace lines and properly connect light to life ring.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2018
Resolution: Replaced life ring.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 November 2018 Resolved
Life ring located on deck 2 has incorrect name on it. Provide life ring with correct name.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2018
Resolution: Replaced life ring.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 28 November 2018 Resolved
Call sign is incorrect on Bridge-to-Bridge and Safety Certificates. Provide certificates with correct call sign. 47 CFR 80.13
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2018
Resolution: Updated documentation.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 November 2018 Resolved
Emergency lighting inoperable in deck 2 stairwell and is missing in deck 2 pantry and port quarter main deck (outside female bathroom). Provide working emergency lighting.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2018
Resolution: Installed emergency lighting.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 28 November 2018 Resolved
Hatch located on port bow deck is missing a securing device. Provide securing device for hatch. 46 CFR 171.124
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2018
Resolution: Wire attached to hatch cover.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 November 2018 Resolved
Fuel vent is missing flame screen. Install 30x30 mesh flame screen. 46 CFR 182.20-35(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2018
Resolution: Flame screen installed,
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 November 2018 Resolved
Life ring located on deck 1 line is worn. Replace line.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2018
Resolution: Line replaced on life ring.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 28 November 2018 Resolved
03 carbonation cylinders located on deck 2 in galley are not properly secured. Secure cylinders.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2018
Resolution: Cylinders properly secured.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 2 April 2018 Resolved
Prove compliance with 49CFR40.25 regarding pre-employee background checks.
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 18 April 2018
Resolution: Examined pre-employment records
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 2 April 2018 Resolved
Prove proper supervisor and crewmember EAP training has been provided.
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 18 April 2018
Resolution: Verified owner had been trained and saw crew training
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 2 April 2018 Resolved
Provide MIS report to U.S. Coast Guard.
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 18 April 2018
Resolution: Rpt was submitted.
Engineering › Bilge Water Management System › Interface Detector
Issued 30 March 2018 Resolved
Audible alarm for bilges is inoperable. Provide an audible alarm loud enough for master to hear.
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 18 April 2018
Resolution: Verified alarm
Fire Fighting › Fire Pumps › Pressure
Issued 30 March 2018 Resolved
Fire pump pressure gage is inoperable. Provide an audible gage.
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 18 April 2018
Resolution: Tested gauge.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 30 March 2018 Resolved
Ensure seasonal employees are enrolled in a USCG approved drug testing program.
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 2 April 2018
Resolution: Conducted DAPI audit
Operations/Management › Drills/Instruction › Not Conducted
Issued 30 March 2018 Resolved
Failed to conduct fire, MOB and security drill during inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2018
Resolved 26 April 2018
Resolution: Witnessed satisfactory underway man overboard drill. Witnessed captain walk crew through a fire drill and security drill.
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 30 March 2018 Resolved
Acquire a Vessel General Permit from the EPA.
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 18 April 2018
Resolution: VGP onboard
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 2 March 2017 Resolved
Perform man overboard drill to the satisfaction of the attending Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 10 April 2017
Resolution: Conducted MOB drill to the satisfaction of the attending Marine Inspector.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 2 March 2017 Resolved
Fill bulkhead penetration in third void.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 9 March 2017
Resolution: vessel rep. filled bulkhead penetrations.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 March 2017 Resolved
Remove dead-end wires in galley or place in electrical box.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 9 March 2017
Resolution: Vessel rep. placed dead end wires in an electrical box.
Fire Fighting › Fire Pumps › Pressure
Issued 8 July 2016 Resolved
Fire was inop and vsl had ordered a new one which had not arrived. Required to replace fire pump. Vsl authorized to operate dock side provide extra bilge pump is onboard and pier-side fire fighting station is accessible.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 July 2016
Resolution: New fire pump installed and tested satisfactory.
Engineering › Bilge Water Management System › Not Operational
Issued 5 July 2016 Resolved
ST01- De-water oil contaminated water from engine room. Oily water to be removed by oil spill removal contractor.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2016
Resolved 8 July 2016
Resolution: Oily water removed.
Engineering › Electric Propulsion System › Battery
Issued 5 July 2016 Resolved
ST02- Prove proper operation of all vessel systems to include main engines, electrical system, bilge system fire main and any other aux system
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2016
Resolved 8 July 2016
Resolution: Tested generators, propulsion system, bilge system, all sat.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 5 July 2016 Resolved
ST03- Clean all oil from E/R bilges.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2016
Resolved 8 July 2016
Resolution: ER was clean.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 19 November 2015 Resolved
Lifejacket storage container on the 03 deck STBD side is missing the marking with number of life jackets.
Condition: Improper/Lack of Maintenance
Due 2 December 2015
Resolved 2 December 2015
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 November 2015 Resolved
First Aid Kit content was expired.
Condition: Invalid
Due 2 December 2015
Resolved 2 December 2015
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 19 November 2015 Resolved
Engineroom distribution panel on aft bulkhead is missing labeling for circuit breakers.
Condition: Improper/Lack of Maintenance
Due 2 December 2015
Resolved 2 December 2015
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 19 November 2015 Resolved
Vessel did not submit MIS report.
Condition: Improper/Lack of Maintenance
Due 2 December 2015
Resolved 2 December 2015
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 November 2015 Resolved
Void forward of the engineroom has holes on forward and aft bulkheads with camera wires passing through them. This prevents bulkheads from being water tight.
Condition: Improper Installation
Due 2 December 2015
Resolved 2 December 2015
Communications › Public Address System › Loudspeaker
Issued 19 November 2015 Resolved
02 deck public address system speakers are inoperable.
Condition: Improper/Lack of Maintenance
Due 9 December 2015
Resolved 10 December 2015
Resolution: Verified operation of PA System
Construction/Loadline › Hull › Bottom Plating
Issued 21 January 2009 Resolved
Provide gauging for marked area located in engine room, one frame forward of aft bulkhead, long keel on the port side, or crop and renew area in accordance with NVIC 7-68.
Action required: 705 - Other - as specified
Resolved 23 January 2009
Resolution: Conducted sat visual inspection and hose test of 50" x 27" insert; no leaks.
Accommodation/Occupational Safety › Ventilation › General
Issued 7 October 2008 Resolved
Repair dampner in the galley on the port side.
Due 7 November 2008
Resolved 4 November 2008
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 7 October 2008 Resolved
Provide emergency instruction list, and post.
Due 7 November 2008
Resolved 4 November 2008
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 7 October 2008 Resolved
Provide cage guard for freezer fan.
Due 7 November 2008
Resolved 4 November 2008
Engineering › Fuel Oil Service System › Hose
Issued 7 October 2008 Resolved
Repair oil leak on port main diesel engine.
Due 7 November 2008
Resolved 4 November 2008
Electrical › Electric Generation Source (service) › Panelboard
Issued 7 October 2008 Resolved
Cover A/C engine room panel starboard side.
Due 7 November 2008
Resolved 4 November 2008
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 October 2008 Resolved
Provide lanyard for emergency escape hatch on starboard side of engine room.
Due 7 November 2008
Resolved 4 November 2008
Electrical › Electric Generation Source (service) › Panelboard
Issued 7 October 2008 Resolved
Screw panel cover to breaker box in galley.
Due 4 November 2008
Resolved 7 November 2008
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 7 October 2008 Resolved
Remove oil from storage area in galley.
Due 7 November 2008
Resolved 4 November 2008
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 7 October 2008 Resolved
Replace batteries on 2 float lights on lifefloats located centerline aft.
Due 7 November 2008
Resolved 4 November 2008
Electrical › Electrical Distribution System (service) › Junction Box
Issued 16 July 2007 Resolved
Provide suitable junction boxes and proper support for electrical conductors of all high bilge level alarms as required by 46 CFR 183.330.
Action required: 705 - Other - as specified
Due 16 August 2007
Resolved 20 August 2007
Electrical › Electric Generation Source (service) › Generator
Issued 16 July 2007 Resolved
Found starboard auxiliary generator field coils fouled with excessive oily residue and dirt. Open, clean and inspect generator. Recommend field coil insulation voltage test referenced in IEEE Standard 45 15.21 be completed by a qualified/licensed marine electrician. (46 CFR 176.800)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2007
Resolved 20 August 2007
Fire Fighting › Structural - Main Vertical Zones › General
Issued 16 July 2007 Resolved
Found fire doors for main deck service pantry missing. Install doors as originally fitted. (46 CFR 177.10-5)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 August 2007
Resolved 20 August 2007
Electrical › Electrical Distribution System (service) › Switch
Issued 16 July 2007 Resolved
Install protective cover for pressure switch on auxiliary air compressor. (46 CFR 183.340)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2007
Resolved 20 August 2007
Electrical › Electrical Distribution System (service) › Conductor
Issued 16 July 2007 Resolved
Provide proper support for conductor in main deck life jacket locker overhead as required by 46 CFR 183.340. (Metal supports every 24 inches)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 August 2007
Resolved 20 August 2007
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 16 July 2007 Resolved
Modify vessel Station Bill required by 46 CFR 185. 514 to include specific duty stations and special duties to be performed by crew members for various emergencies.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 August 2007
Resolved 20 August 2007
Electrical › Electrical Distribution System (service) › Conductor
Issued 16 July 2007 Resolved
Replace waster cable hangers in various locations on pilot house deck. (46 CFR 183.340)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2007
Resolved 20 August 2007
Lifesaving › Lifefloat › Serviceable
Issued 16 July 2007 Resolved
Service all life floats, sea painters, pendants, life lines and electric floating lights. (46 CFR 176.800)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2007
Resolved 20 August 2007
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 16 July 2007 Resolved
Provide current copy of Inland Navigation Rules required by 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 16 August 2007
Resolved 20 August 2007
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 16 July 2007 Resolved
Repair broken/wasted securing latch on PFD Storage locker, main deck. (176.800)
Action required: 705 - Other - as specified
Due 16 August 2007
Resolved 20 August 2007
Construction/Loadline › Hull › Hull Plating
Issued 27 February 2007 Resolved
Transom plate wasted from water being trapped between hull plating and reinforcement ring around port gen outlet.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2007
Resolved 6 March 2007
Engineering › Steering Gear System › Fastener
Issued 27 February 2007 Resolved
Replace missing nut on steering flange, port side rudder
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2007
Resolved 6 March 2007
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 27 February 2007 Resolved
Fire doors would not close
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2007
Resolved 6 March 2007
Fire Fighting › Structural - A Class Divisions › Door Frames
Issued 27 February 2007 Resolved
Make permanent repairs to fire door in galley
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2007
Resolved 6 March 2007
Engineering › Bilge Water Management System › Strainer
Issued 27 February 2007 Resolved
Repair or replace bilge suction in #2 void space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2007
Resolved 6 March 2007
Lifesaving › Lifebuoys › Serviceable
Issued 10 October 2006 Resolved
Provide minimum coverage of retro-tape on all lifering buoys. Noted lifebuoys to have approx. 50% of the required retro-tape. 46CFR122.604
Action required: 705 - Other - as specified
Due 10 November 2006
Resolved 18 October 2006
Documentation › Markings/Placards › Lifejacket Placard
Issued 10 October 2006 Resolved
Post lifejacket donning placard on main deck in a visible location. 46CFR122.516
Action required: 705 - Other - as specified
Due 10 November 2006
Resolved 18 October 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 10 October 2006 Resolved
Noted (1) B-I portable fire extinguisher out of date for inspection. 46CFR176
Action required: 705 - Other - as specified
Due 10 November 2006
Resolved 18 October 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 October 2006 Resolved
Repair or replace heavily damaged wiring on mixer in kitchen service area. 46CFR183
Action required: 705 - Other - as specified
Due 10 November 2006
Resolved 18 October 2006
Electrical › Lighting (emergency) › Lighting Fixture
Issued 10 October 2006 Resolved
Repair non-operative emergency lighting, 02 deck. 46CFR183
Action required: 705 - Other - as specified
Due 10 November 2006
Resolved 18 October 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 September 2005 Resolved
Replace expired medications in first aid kit. (46 CFR 184.710)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2005
Resolved 20 October 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 20 September 2005 Resolved
Provide evidence of inspection for portable fire extinguisher in machinery space. (46 CFR 176.810)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2005
Resolved 20 October 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 20 September 2005 Resolved
Replace broken protective globe on light fixture in forward hold. (46 CFR 183.430)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2005
Resolved 20 October 2005
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 20 September 2005 Resolved
Repair cooling water leak on port propulsion engine keel cooler flex hose assembly. (46 CFR 176.800).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2005
Resolved 20 October 2005
Engineering › Lubricating Oil Service System › Hose
Issued 20 September 2005 Resolved
Replace worn oil change flex hose assembly on starboard propulsion engine. (46 CFR 176.800).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2005
Resolved 20 October 2005
Electrical › Electrical Distribution System (service) › Panelboard
Issued 20 September 2005 Resolved
Secure electrical distribution panel board covers in machinery space. (46 CFR 183.330)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2005
Resolved 20 October 2005
Electrical › Electrical Distribution System (service) › Panelboard
Issued 20 September 2005 Resolved
Install suitable blanks in electrical panel board in pantry. (46 CFR 183.330).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 October 2005
Resolved 20 October 2005
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 20 September 2005 Resolved
Post station bill in conspicuous locations throughout vessel. (46 CFR 185.514)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2005
Resolved 20 October 2005
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 20 September 2005 Resolved
Include general description of crew training and log drills conducted. (46 CFR 185.420)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2005
Resolved 20 October 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 September 2005 Resolved
Demonstrate proper operation of stern navigation light. (46 CFR 183.420)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2005
Resolved 20 October 2005
Construction/Loadline › Structures › Door
Issued 28 February 2005 Resolved
Adjust fire door in A-60 fire boundary (galley trunk) to allow for automatic closure and rove hold back rope.
Action required: 705 - Other - as specified
Due 5 March 2005
Resolved 9 March 2005
Construction/Loadline › Structures › Transverse Bulkhead
Issued 28 February 2005 Resolved
Found lower sill of A-0 fire door in A-60 structural fire protection boundary not tight fitted on lower sill (approx 1/2 inch gap). Make temporary repairs to satisfaction of attending inspector not later than 05 MAR 2005.
Action required: 705 - Other - as specified
Due 5 March 2005
Resolved 9 March 2005
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 17 February 2005 Resolved
Found port and stbd strut and intermediate bearing worn beyond maximum clearances listed in ABYC P-6 Table V. Renew in kind (46 CFR 176.800).
Action required: 705 - Other - as specified
Due 17 March 2005
Resolved 28 February 2007
Resolution: All bearing renewed.
Engineering › Steering Gear System › Rudder Bearing
Issued 17 February 2005 Resolved
Found port and starboard rudder bushings worn beyond maximum clearences. Renew in kind (46 CFR 176.800).
Action required: 705 - Other - as specified
Due 17 March 2005
Resolved 28 February 2007
Resolution: All bushings renewed
Accommodation/Occupational Safety › Potable Water System › General
Issued 17 February 2005 Resolved
Provide suitable securing devices for hot water heaters in machinery space and #4 Void space (46 CFR 182.320)
Action required: 705 - Other - as specified
Due 17 March 2005
Resolved 28 February 2007
Construction/Loadline › Structures › Manhole
Issued 17 February 2005 Resolved
Replace gasket and install captive chain on fore peak MHC and prove water tight by acceptable method. (46 CFR 179.360)
Action required: 705 - Other - as specified
Due 17 March 2005
Resolved 28 February 2007
Engineering › Sea-water System (primary cooling) › Valve
Issued 17 February 2005 Resolved
Renew stainer basket on auxiliary cooling water sea strainer assembly (46 CFR 177.800). Non-vital piping system.
Action required: 705 - Other - as specified
Due 17 March 2005
Resolved 28 February 2007
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 17 February 2005 Resolved
Replace wasted/frozen sea chest vent gate valve. (46 CFR 177.800).
Action required: 705 - Other - as specified
Due 17 March 2005
Resolved 28 February 2007
Engineering › Fuel Oil Service System › Piping
Issued 17 February 2005 Resolved
Repair leak in diesel fuel oil fill piping in way of #3 Void and prove tight by acceptable method. (46 CFR 177.800).
Action required: 703 - Prior to bunkering operations
Due 17 March 2005
Resolved 28 February 2007
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 17 February 2005 Resolved
Remove all excess combustible materials, trash and debris from voids #3 and 4. (Unsafe Practice - 46 CFR 176.840).
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 March 2005
Resolved 28 February 2007
Construction/Loadline › Structures › Door
Issued 17 February 2005 Resolved
Found A-0 door sill crushed and wasted in galley A-60 primary fire boundary. Repair in kind as specified on USCG approved initial construction plans and demonstrate proper installation and operation of door.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 March 2005
Resolved 28 February 2007
Resolution: Repairs completed but found un sat. Approx i/2/ gap noted at lower portion of sill . Door not tight fitted and held back by rope. Reissued requirement to effect temporary repairs, remove rope and prove proper operation of door.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 17 February 2005 Resolved
Make permanent repairs to A-60 fire boundary in galley in way of lower sill of A-0 fire door. Repairs are to be completed to "as built" specifications in USCG approved structural fire protection plans 46 CFR 177.10-5 (a).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 March 2006
Resolved 10 October 2006
Construction/Loadline › Structures › Transverse Bulkhead
Issued 17 February 2005 Resolved
Found lower sill of A-0 fire door in A-60 structural fire boundary not tight fitting to transverse bulk head. Make temporary repairs to the satisfaction of the attending inspector not later than 05 MAR 2005. Permant repairs are to be completed as original construction not later than next required USCG Hull Examination.
Action required: 705 - Other - as specified
Due 5 March 2005
Resolved 9 March 2005
Resolution: Metallic plate (approx 1.5 mm thick) was close fit, gasketed and bolted into position. Concidered satisfactory temporary repair.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 12 October 2004 Resolved
Repair starboard transmission pressure guage 46 CFR 184.620.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 November 2004
Resolved 8 November 2004
Stability › Watertight Integrity › General
Issued 12 October 2004 Resolved
Remove water from forepeak 46 CFR 176.802.
Condition: Improper/Lack of Maintenance
Due 15 October 2004
Resolved 15 October 2004
Stability › Watertight Integrity › General
Issued 12 October 2004 Resolved
Adjust watertight door so that it fully closes 46 CFR 176-179.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2004
Resolved 15 October 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 October 2004 Resolved
Remove deadend wiring 46 CFR 183.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 October 2004
Resolved 15 October 2004
Electrical › Lighting (emergency) › Lighting Fixture
Issued 12 October 2004 Resolved
Repair emergency lighting located forward on 02 deck 46 CFR 183.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2004
Resolved 15 October 2004
Electrical › Electric Supply System (service) › Battery Installation
Issued 12 October 2004 Resolved
Clean battery boxes and cable connections 46 CFR 183.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2004
Resolved 15 October 2004
Engineering › Bilge Water Management System › Not Operational
Issued 12 October 2004 Resolved
Repair high level alarm for stern compartment 46 CFR 182.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2004
Resolved 15 October 2004
Engineering › Bilge Water Management System › Strainer
Issued 12 October 2004 Resolved
Repair bilge strainers on both engine room and stern bilge pumps 46 CFR 182.
Action required: 705 - Other - as specified
Due 15 November 2004
Resolved 8 November 2004
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 12 October 2004 Resolved
Repair excessive leaking on port shaft 46 CFR 176.802c.
Action required: 705 - Other - as specified
Due 12 November 2004
Resolved 8 November 2004
Lifesaving › Lifebuoys › Serviceable
Issued 12 October 2004 Resolved
Mark ring life buoys with 4 evenly spaced areas of retro tape 46 CFR 185.
Action required: 705 - Other - as specified
Due 15 October 2004
Resolved 15 October 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 12 October 2004 Resolved
Replace dented B-II portable fire extinguisher 46 CFR 176.810.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2004
Resolved 15 October 2004
Lifesaving › Lifefloat › Painter
Issued 12 October 2004 Resolved
Replace painters on life floats 46 CFR 180
Action required: 705 - Other - as specified
Due 12 November 2004
Resolved 9 November 2004
Lifesaving › Lifefloat › Float Free
Issued 12 October 2004 Resolved
Stow lifefloats in a float free arrangement 46 CFR 180.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2004
Resolved 8 November 2004
Lifesaving › Buoyant Apparatus
Issued 16 September 2003 Resolved
Renew 3 life floats vessel is restricted to carrying less than 469 total persons, or prior to 16 Oct 03 as required by Special Inspection Note dated 22 JUL 93.
Action required: 705 - Other - as specified
Due 16 October 2003
Resolved 16 October 2003
Resolution: Owner renewed 3 lifefloats.
Lifesaving › Lifebuoys
Issued 16 September 2003 Resolved
Renew 4 identified by marine inspector prior to carrying passengers for hire. LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 705 - Other - as specified
Due 16 September 2003
Resolved 16 September 2003
Resolution: Corrected during the course of the inspection.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 16 September 2003 Resolved
Repair port main engine Temp gauge prior to 16 Oct 03 as required by 46 CFR 184.620.
Action required: 705 - Other - as specified
Due 16 October 2003
Resolved 16 October 2003
Resolution: Owner repaired port main engine temp guage.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 16 September 2003 Resolved
Repair stbd. main engine oil pressure gauge prior to 16 Oct 03 as required by 46 CFR 184.620.
Action required: 705 - Other - as specified
Due 16 October 2003
Resolved 16 October 2003
Resolution: Owner repaired stbd main engine oil pressure guage.
Lifesaving › Lifejacket/PFD (General)
Issued 18 July 2002 Resolved
Re-attach Lifejacket Placards to stowage containers located on the third level, port side aft and third level aft deck area. LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Due 2 August 2002
Resolved 1 August 2002
Lifesaving › Buoyant Apparatus
Issued 18 July 2002 Resolved
Demonstrate operation of the lifefloat waterlight located in after row, 2nd inboard lifefloat from port side (2 high). LEGACY COMPONENT DESC: Automatic waterlight
Condition: Unknown
Due 2 August 2002
Resolved 1 August 2002
Accommodation/Occupational Safety › Cooking Systems
Issued 18 July 2002 Resolved
Clean galley ventilation hood grease traps over the griddle and deep fryers. LEGACY COMPONENT DESC: Grease Traps
Condition: Improper/Lack of Maintenance
Due 2 August 2002
Resolved 1 August 2002
Lifesaving
Issued 29 September 2000 Resolved
Install means of retrieving persons from the water at embarkatoin station.
Condition: Unknown
Due 30 September 2000
Resolved 6 October 2000
Lifesaving
Issued 29 September 2000 Resolved
Prior to the carriage of passengers, add vent closures and vent shut downs to the emergency procedures and post procedures throughout the vessel.
Condition: Unknown
Due 30 September 2000
Resolved 6 October 2000
Lifesaving
Issued 29 September 2000 Resolved
Prior to the carriage of passengers, conduct fire and man overboard drills with full crew to the satisfaction of COast Guard inspector.
Condition: Unknown
Due 30 September 2000
Resolved 6 October 2000
Lifesaving
Issued 29 September 2000 Resolved
Priovide Type III PFD's, for deckhands involved in Man Overboard evolution.
Condition: Unknown
Due 30 September 2000
Resolved 6 October 2000
Lifesaving
Issued 13 September 2000 Resolved
PROVIDE MISSING ITEMS FROM FIRST AID KIT INVENTORY 4 ITEMS. PRIOR TO 13 OCT00 IAW 46 CFR 184. 710
Condition: Unknown
Due 6 March 2001
Resolved 6 March 2001
Electrical
Issued 13 September 2000 Resolved
INSTALL BATTERY BOX FASTENERS FOR COVERS IAW 46 CFR 183.220 PRIOR TO 13 OCT00.
Condition: Unknown
Due 6 March 2001
Resolved 6 March 2001
Lifesaving
Issued 13 September 2000 Resolved
PROVIDE LIFE JACKET DONNING PLACARD IN VICINITY OF THE LIFE JACKET STORAGE BOX'S MAIN DECK AND FIRST DECK IAW 46 CFR 185.512 PRIOR TO 13 OCT 00.
Condition: Unknown
Due 6 March 2001
Resolved 6 March 2001
Unknown
Issued 13 September 2000 Resolved
VESSEL IS TO INSTALL THE PROPER HOT WATER HEATER RELIEF VALVE _<100PSI IAW 46 CFR 53.04 PRIOR TO 13 OCT 00
Condition: Unknown
Due 6 March 2001
Resolved 6 March 2001
Accommodation/Occupational Safety
Issued 25 May 1995 Resolved
Clean debris from bilge #3 compartment.
Condition: Unknown
Due 19 June 1995
Resolved 19 June 1995
Construction/Loadline
Issued 25 May 1995 Resolved
Install pipe plugs in 2 bulkhead penetration starboard side between #3 and #4 compartments.
Condition: Unknown
Due 19 June 1995
Resolved 19 June 1995
Engineering
Issued 25 May 1995 Resolved
Repair leaking keel cooler plug #4 compartment under ladder.
Condition: Unknown
Due 19 June 1995
Resolved 19 June 1995
Engineering
Issued 11 October 1994 Resolved
Prior to carrying passengers for hire repair port and starboard screws and prove alignment on both shafts.
Condition: Unknown
Due 10 November 1994
Resolved 10 November 1994
Navigation
Issued 11 October 1994 Resolved
Prior to carrying passengers for hire remove and repair port and starboard rudders.
Condition: Unknown
Due 10 November 1994
Resolved 10 November 1994
Construction/Loadline
Issued 11 October 1994 Resolved
Drydock vessel to evaluate allision damage. Vessel may not carry passengers until this requirement is satisfied.
Condition: Unknown
Due 14 November 1994
Resolved 14 November 1994

Casualty record · 1

24 November 2012Routine · role: Moored/Anchored in Vicinity of Primary Subject · activity 4492154
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

LADY ANDERSON (2012). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.