Records from 2012 to 2026. Most recent: inspection, 19 May 2026.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 May 2026
Resolved
[Exhaust piping] must be gas tight throughout its length.
A medium-sized leak of exhaust gas was found in the lazarette coming from the starboard engine's exhaust piping, leaking exhaust gas into the space. Additionally, the lazarette access hatch is inside the passenger accommodation space and is not fitted with a gas-tight seal.
46 CFR 182.15-20 (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 5 June 2026
Resolution: Operator fixed the exhaust leak
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 19 May 2026
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible.
Electronic chart installed on board could not be confirmed compliant with RTCM 10900 standards. Paper charts on board were older than 6 months and therefore out of date.
46 CFR 121.420(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 5 June 2026
Resolution: Operator procured up to date chart
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 May 2026
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
Sixty (60) life jackets were found to have deteriorated buoyant foam (45 from 2nd deck, 15 from 3rd deck). Vessel may not operate with more than 364 total passengers on board.
46 CFR 117.71(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 5 June 2026
Resolution: Operator procured required number of new life jackets.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 May 2026
Resolved
Each nozzle must be of a type approved in accordance with approval series 162.027.
Fire nozzle on 2nd deck fire hose was not capable of producing a water spray pattern.
46 CFR 118.320(c)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 5 June 2026
Resolution: New fire nozzle installed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 19 May 2026
Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight.
Plastic discharge piping from aft kitchenette attached
to the starboard hull had a small opening allowing daylight through.
46 CFR 171.114(a)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 5 June 2026
Resolution: Operator installed new discharge line to fix the hole.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 19 May 2026
Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members.
Both speakers on 3rd deck passenger deck were not operational.
46 CFR 121.610(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2026
Resolved 5 June 2026
Resolution: PA system is fully operational
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 May 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 127 adult life jackets were found in a damaged condition and removed from service. Replace life jackets removed from the vessel. Vessel is limited to a total maximum of 343 persons on board until appropriate number of life jackets are on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 24 June 2025
Resolution: Operator had procured 130 new lifejackets, labeled them and stowed them on the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 May 2025
Resolved
A door in a bulkhead required to be A-60 Class must be capable of meeting the requirements of an A-15 Class bulkhead. The door handles on the deck 03 stairtower doors were loose and not forming a fire boundary. Tighten/replace to the satisfaction of the Coast Guard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 24 June 2025
Resolution: Operator tightened the doorknobs.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 May 2025
Resolved
Waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Waste receptacles on the vessel are plastic combustible types. Replace waste receptacles with noncombustible ones.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 24 June 2025
Resolution: Operator replaced plastic waste recepticles with metal ones.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 May 2025
Resolved
Each distribution panel or switchboard must be totally enclosed. The engine room port distribution panel had a missing punch out circular plate on the side of the panel box. Replace missing punch out plate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 24 June 2025
Resolution: Operator installed a cover for the punch-out on the panel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 June 2024
Resolved
An adult life jacket must be provided for each person carried on board a vessel. MI observed 06 life jackets with failed inner foam material. Total Persons Allowed On Board is reduced to 464 until replacement lifejackets are onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2024
Resolution: Operator submitted objective evidence in the form of photographs showing new lifejackets had been procured and installed on the vessel.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 June 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. MI observed wastage in the aft support gussets on both rudderposts as well as on the 1st transverse frame, starboard side, aft of the forward bulkhead in way of the chine to inboard longitudinal frame. Operator to submit plan to repair prior to next credit hull inspection.
Action required: 705 - Other - as specified
Due 31 December 2025
Resolved 18 November 2025
Resolution: Operator replaced the gusset.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 June 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to: Minimize accidental personnel contact with energized parts. MI observed 04 openings inside distribution panel in galley and exposed wire ends in an overhead light in the galley.
Action required: 10 - Deficiency Rectified
Resolved 17 June 2024
Resolution: Operator installed breaker blanks in the distribution panel and installed a new light fixture in the galley.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 June 2024
Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. MI observed that the lifeline on 02 ringbuoys were deteriorated and breaking when flexed.
Action required: 10 - Deficiency Rectified
Resolved 17 June 2024
Resolution: Operator installed new lifelines on the ring buoys.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 June 2024
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. MI observed the portable light at the operating station had very weak batteries and there was no portable light outside the propulsion machinery space.
Action required: 10 - Deficiency Rectified
Resolved 17 June 2024
Resolution: Operator procured new portable lights.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 29 November 2023
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Superstructure bulkhead bottom, at the aft port door-sill, found wasted through and open to the weather. Crop and renew to good steel, to the satisfaction of the attending Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 29 November 2023
Resolved 8 December 2023
Resolution: Insert repaired after failing NDT on 06Dec. Repairs made by O/O on 08Dec, passed NDT, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 24 June 2022
Resolved
The alcohol testing of each individual must be conducted within 2 hours of when the SMI occurs. Alcohol testing equipment was was expired. Obtain approved testing equipment and keep onboard at all times.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2022
Resolved 6 July 2022
Resolution: New test strips are now onboard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 June 2022
Resolved
Each distribution panel must be protected from falling debris and dripping/splashing water. The front cover hardware on the pilothouse was broken allowing foreign object and water ingress. Repair/replace junction box as necessary to keep debris/water out.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2022
Resolved 6 July 2022
Resolution: New cover was installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 July 2021
Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel operated without a valid COI.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 16 July 2021
Resolved 16 July 2021
Resolution: Completed COI inspection and issued valid COI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 November 2019
Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. The company has been enrolled in a non DOT drug testing program where results are not reviewed by a Medical Review Officer. Company must conduct pre-employment DOT drug testing for all employees who hold a safety sensitive position on the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 November 2019
Resolved 18 November 2019
Resolution: Company re-enrolled with Quest diagnostics in DOT program.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 November 2019
Resolved
The selection of crewmembers for random drug testing shall be made by a scientifically valid method, with each covered crewmember having an equal chance of being tested each time selections are made. Company is currently not using a scientifically valid method in selecting employees for random drug testing. Company shall use an approved method for selecting crewmembers for random drug testing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 November 2019
Resolved 18 November 2019
Resolution: Company is now utilizing a proper method for random drug testing selection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 November 2019
Resolved
The employer shall provide an Employee Assistance Program (EAP) for all crewmembers. Specifically, an EAP training program must be conducted for the employer’s crewmembers and supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. Company currently does not conduct EAP training with crewmembers or supervisors. Company shall complete at least 60 minutes of EAP training with supervisors and general training for all other crewmembers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 November 2019
Resolved 18 November 2019
Resolution: Company provided proof of EAP training for supervisors and all covered personnel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 November 2019
Resolved
Drug testing programs required by this part must be conducted in accordance with 49 CFR part 40, Procedures for Transportation Workplace Testing Programs. The company is not compliant with, specifically but not limited to part 16.201. **Must bring drug testing program into full compliance prior to carrying passengers**
Action required: 705 - Other - as specified
Resolved 18 November 2019
Resolution: DAPI AUDIT Conducted and complete
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 5 November 2019
Resolved
Decks of the ‘‘A’’ Class shall be so insulated with approved structural insulation, deck covering that the average temperatures on the unexposed side would not rise more than 250 °F. above the original temperature, nor would the temperature at any one point, including any joint, rise more than 325 °F. above the original temperature, within the time listed below: Class A–60, 60 minutes. If the pipe passes through an A-60 division, approved structural insulation should be applied to the pipe on the insulated side of the division for a distance of at least 300 mm (12 inches).
The A-60 deck fire boundary located on the overhead within the engine room is missing A-60 insulation in two locations where pipe penetrations are located.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2019
Resolved 20 November 2019
Resolution: Recified deficiency
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 November 2019
Resolved
The Certificate of Inspection (COI) must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. Vessel has expired temporary COI posted in restricted pilot house on the navigation bridge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2019
Resolved 20 November 2019
Resolution: Recified deficiency
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 November 2019
Resolved
Charts and nautical publications. (a) As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; vessel has on board out dated paper charts (2009) & outdated electronic charts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2019
Resolved 20 November 2019
Resolution: Recified deficiency
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 5 November 2019
Resolved
Each hydrostatic release unit, other than a disposable unit, must be serviced within 12 months of its manufacture and within 12 months of each subsequent subsequent servicing. Each disposable hydrostatic release unit must be marked in clearly legible letters with an expiration date of two years after the date on which the unit is installed. EPIRB hydrostatic release unit is expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2019
Resolved 20 November 2019
Resolution: Recified deficiency
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 November 2019
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or equivalent contents. First Aid Kit contents are expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2019
Resolved 20 November 2019
Resolution: Recified deficiency
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 November 2019
Resolved
All microprocessor or computer based systems must meet the requirements of part 62 in subchapter F. Vessel operators could not provide Design Test Verification Procedures or any USCG review of installation.
Action required: 705 - Other - as specified
Due 5 May 2020
Resolved 14 October 2020
Resolution: Vessel developed and submitted plans. Tested locally. Approval letter recieved from MSC.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 November 2019
Resolved
Protect passengers, crew, and the vessel from electrical hazards, including fire, caused by or in electrical equipment, and electrical shock. The outside light on 3rd deck is not hardwired to the electrical system
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2019
Resolved 20 November 2019
Resolution: Recified deficiency
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 November 2019
Resolved
A vessel must comply with the applicable requirements as set forth in 47 CFR 80. FCC Safety Radio Certificate not on board vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2019
Resolved 20 November 2019
Resolution: Recified deficiency
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 28 November 2018
Resolved
Amp meter does not work. Provide working amp meter for generator distribution panel. 46 CFR 183.10-5(g)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2018
Resolution: Repaired inoperable amp meter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 28 November 2018
Resolved
Battery charger does not have an amp meter. Provide in line amp meter on battery charger. 46 CFR 183.05-20(f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2018
Resolution: Installed amp meter.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Other (MARPOL Annex VI)
Issued 28 November 2018
Resolved
Sewage discharge valve is not secured. Provide a method of securing overboard discharge.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2018
Resolution: Installed lock and chain on the overboard discharge valve.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 November 2018
Resolved
Life jacket donning placards are illegible on deck 2 forward, port & starboard. Provide legible life jacket donning placards.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2018
Resolution: Provided new life jacket donning instructions.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 November 2018
Resolved
Life ring located on deck 3 is worn and the light is incorrectly spliced together. Replace lines and properly connect light to life ring.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2018
Resolution: Replaced life ring.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 November 2018
Resolved
Life ring located on deck 2 has incorrect name on it. Provide life ring with correct name.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2018
Resolution: Replaced life ring.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 28 November 2018
Resolved
Call sign is incorrect on Bridge-to-Bridge and Safety Certificates. Provide certificates with correct call sign.
47 CFR 80.13
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2018
Resolution: Updated documentation.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 November 2018
Resolved
Emergency lighting inoperable in deck 2 stairwell and is missing in deck 2 pantry and port quarter main deck (outside female bathroom). Provide working emergency lighting.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2018
Resolution: Installed emergency lighting.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 28 November 2018
Resolved
Hatch located on port bow deck is missing a securing device. Provide securing device for hatch.
46 CFR 171.124
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2018
Resolution: Wire attached to hatch cover.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 November 2018
Resolved
Fuel vent is missing flame screen. Install 30x30 mesh flame screen.
46 CFR 182.20-35(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2018
Resolution: Flame screen installed,
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 November 2018
Resolved
Life ring located on deck 1 line is worn. Replace line.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2018
Resolution: Line replaced on life ring.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 28 November 2018
Resolved
03 carbonation cylinders located on deck 2 in galley are not properly secured. Secure cylinders.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2018
Resolution: Cylinders properly secured.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 2 April 2018
Resolved
Prove compliance with 49CFR40.25 regarding pre-employee background checks.
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 18 April 2018
Resolution: Examined pre-employment records
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 2 April 2018
Resolved
Prove proper supervisor and crewmember EAP training has been provided.
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 18 April 2018
Resolution: Verified owner had been trained and saw crew training
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 2 April 2018
Resolved
Provide MIS report to U.S. Coast Guard.
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 18 April 2018
Resolution: Rpt was submitted.
Engineering › Bilge Water Management System › Interface Detector
Issued 30 March 2018
Resolved
Audible alarm for bilges is inoperable. Provide an audible alarm loud enough for master to hear.
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 18 April 2018
Resolution: Verified alarm
Fire Fighting › Fire Pumps › Pressure
Issued 30 March 2018
Resolved
Fire pump pressure gage is inoperable. Provide an audible gage.
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 18 April 2018
Resolution: Tested gauge.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 30 March 2018
Resolved
Ensure seasonal employees are enrolled in a USCG approved drug testing program.
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 2 April 2018
Resolution: Conducted DAPI audit
Operations/Management › Drills/Instruction › Not Conducted
Issued 30 March 2018
Resolved
Failed to conduct fire, MOB and security drill during inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2018
Resolved 26 April 2018
Resolution: Witnessed satisfactory underway man overboard drill. Witnessed captain walk crew through a fire drill and security drill.
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 30 March 2018
Resolved
Acquire a Vessel General Permit from the EPA.
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 18 April 2018
Resolution: VGP onboard
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 2 March 2017
Resolved
Perform man overboard drill to the satisfaction of the attending Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 10 April 2017
Resolution: Conducted MOB drill to the satisfaction of the attending Marine Inspector.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 2 March 2017
Resolved
Fill bulkhead penetration in third void.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 9 March 2017
Resolution: vessel rep. filled bulkhead penetrations.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 March 2017
Resolved
Remove dead-end wires in galley or place in electrical box.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 9 March 2017
Resolution: Vessel rep. placed dead end wires in an electrical box.
Fire Fighting › Fire Pumps › Pressure
Issued 8 July 2016
Resolved
Fire was inop and vsl had ordered a new one which had not arrived. Required to replace fire pump. Vsl authorized to operate dock side provide extra bilge pump is onboard and pier-side fire fighting station is accessible.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 July 2016
Resolution: New fire pump installed and tested satisfactory.
Engineering › Bilge Water Management System › Not Operational
Issued 5 July 2016
Resolved
ST01- De-water oil contaminated water from engine room. Oily water to be removed by oil spill removal contractor.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2016
Resolved 8 July 2016
Resolution: Oily water removed.
Engineering › Electric Propulsion System › Battery
Issued 5 July 2016
Resolved
ST02- Prove proper operation of all vessel systems to include main engines, electrical system, bilge system fire main and any other aux system
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2016
Resolved 8 July 2016
Resolution: Tested generators, propulsion system, bilge system, all sat.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 5 July 2016
Resolved
ST03- Clean all oil from E/R bilges.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2016
Resolved 8 July 2016
Resolution: ER was clean.