MAURY USCG vessel records Sign in
← All vessels

TALISMAN

TALISMAN is a 1993 freight ship. The Coast Guard has recorded 26 inspections since 1993, most recently in March 2017, along with 12 deficiencies and 2 operational controls.

Records from 1993 to 2017. Most recent: inspection, 15 March 2017.

Built
1993
Last inspected
15 March 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8918942 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
390437
Flag
CURACAO
—
Maury page id
psix-390437

Inspections, by type

…with no type recorded16
Years with a record 15 calendar years (1993–2017)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it42515 - Convention (Subpart B), Gross Ton
12755 - Convention (Subpart B), Net Ton
54320 - Dead Weight, Ton
75570 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 26

15 March 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6099451
12 March 2017 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6103672
24 June 2014 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4897152
1 November 2010 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3871004
14 August 2008 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3298605
27 July 2008 PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3270756
11 May 2005 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2355423
26 February 2003 MARPOL Annex I Examination · Ballast Water Examination · Tank Vessel Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1748221
2 February 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1486745
28 August 2001 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 293351
9 August 2001 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 292855
9 August 2001 Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1069709
21 August 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 431981
12 July 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 430494
5 December 1998 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 423220
14 December 1997 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 410815
14 December 1997 Tank Vessel Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 779576
11 October 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 396241
11 October 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 396489
17 October 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 383926
5 July 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 519941
20 October 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 371281
20 October 1994 Tank Vessel Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1359960
9 July 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 536215
18 October 1993 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 462721
29 August 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 505808

Deficiency record · 12

Stability › Watertight Integrity › General
Issued 15 March 2017 Resolved
1099-Other(Alarms-Signals)Doorsprovided to ensure watertight integrity of internal openings as sliding watertight doors shall have indicators provided at the control position showing whether the doors are open or closed, and an audible alarm to be provided at the door closure. The audible and visual alarm did not work on the aft side of the watertight sliding door. 74 SOLAS(04) II-1/25-9.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 March 2017
Resolution: Vessel resolved the problem with the sliding water tight door alarm.
Unknown
Issued 9 August 2001 Resolved
Make permanent repairs to the upper and middle site glass on msd tank
Condition: Unknown
Due 14 August 2001
Resolved 14 August 2001
Engineering
Issued 9 August 2001 Resolved
Air feed clutch line
Condition: Unknown
Due 14 August 2001
Resolved 14 August 2001
Fire Fighting
Issued 9 August 2001 Resolved
Fire hoses
Condition: Unknown
Due 14 August 2001
Resolved 14 August 2001
Fire Fighting
Issued 9 August 2001 Resolved
(A-60) fire boundairy doors
Condition: Unknown
Due 14 August 2001
Resolved 14 August 2001
Deck/Cargo
Issued 9 August 2001 Resolved
Inert Gas and shutdowns
Condition: Unknown
Due 14 August 2001
Resolved 14 August 2001
Deck/Cargo
Issued 9 August 2001 Resolved
IG feed line
Condition: Unknown
Due 14 August 2001
Resolved 14 August 2001
Deck/Cargo
Issued 9 August 2001 Resolved
IG grounding
Condition: Unknown
Due 14 August 2001
Resolved 14 August 2001
Engineering
Issued 9 August 2001 Resolved
Steam leak at #1 boiler site glass
Condition: Unknown
Due 14 August 2001
Resolved 14 August 2001
Fire Fighting
Issued 9 August 2001 Resolved
Emergency escape door
Condition: Unknown
Due 14 August 2001
Resolved 14 August 2001
Deck/Cargo
Issued 12 July 1999 Resolved
starboardside flange on crossover between #1 and #2 discharge flanges is leaking product._x001C_ ---33 CFR 156.120(p)---
Condition: Unknown
Due 23 August 1999
Resolved 23 August 1999
Deck/Cargo
Issued 20 October 1994 Resolved
IGS system was not calibrated.
Condition: Unknown
Due 3 November 1994
Resolved 3 November 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.