← All vessels
CAPE RACE
Freight Ship · General Dry Cargo Ship class · Built 1990s · USCG Southeast District (CGD-SE) · Other hulls named CAPE RACE
CAPE RACE is a 1993 freight ship. The Coast Guard has recorded 17 inspections since 1993, most recently in January 2009, along with 4 deficiencies and 3 operational controls.
Records from 1993 to 2009. Most recent: operational control imposed, 23 January 2009.
- Built
- 1993
- Last inspected
- 23 January 2009
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 4 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9005417 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ELRN5
390487
Flag
FRANCE
—
Maury page id
psix-390487
Inspections, by type
…with no type recorded6
Years with a record
6 calendar years (1993–2009)
The 17 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it29912 - Convention (Subpart B), Gross Ton
12454 - Convention (Subpart B), Net Ton
12454 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 17
23 January 2009
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3398651
23 January 2009
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3398854
22 January 2009
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3401390
20 January 2009
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3396765
8 December 2008
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3376464
7 December 2008
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3375880
31 October 2008
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3355066
22 September 2008
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3330339
11 September 2008
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3323468
21 July 2008
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3274454
20 June 2008
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3242746
11 January 2008
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3127838
24 March 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1762859
29 March 2002
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1598885
4 January 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 453296
18 October 1993
Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1140599
27 August 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 360431
Deficiency record · 4
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (air start)
Issued 23 January 2009
Resolved
The 3/2 way valve 2154A on the starting air distributor failed to operate due to pressure losses such as clogged control air filters, leakages etc. and the engine could no longer be started. See "New Sulzer Diesel" Service Bulletin in Documents section.
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 7 December 2008
Resolved
Vessel reported that there Gyro repeater found on the helm is inoperable. Vessel is to have the repeater fixed, or submit a plan detailing when it is supposed o be fixed prior to departure.
Personnel › Training › Familiarization Training
Issued 21 July 2008
Resolved
Vessel HAZMAT employees onboard do not have required HAZMAT employee training as required by regulations. In addition, Chief Mate does not have appropriate Dangerous Goods/ HAZMAT training as required by STCW.
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 21 July 2008
Resolved
As per vessel's SMS Section 2.20.1 master and C/O must be in possession of valid dangerous cargo/hazardous material training certificates. C/O does not have an appropriate certificate, in addition vessel's SMS section 2.30.3 requires that all crew members must hold hazmat employee training records. No records can be provided.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.