Records from 1993 to 1995. Most recent: inspection, 14 January 1995.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 12
14 January 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 101241
9 January 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 374047
12 August 1994
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1174791
29 June 1994
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1174054
26 May 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 367553
26 May 1994
Control Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 860741
25 March 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 455504
15 March 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 693915
27 January 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 92241
21 July 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 693916
24 June 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 109207
15 June 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 358918
Fire Fighting
Issued 9 January 1995
Resolved
PRIOR TO DEPARTURE FROM THE PORT OF HOUSTON, PROVE PROPER OPERATION OF THE EMERGENCY FIRE PUMP
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Engineering
Issued 9 January 1995
Resolved
PRIOR TO DEPARTURE FROM THE PORT OF HOUSTON, PROVE PROPER OPERATION OF THE OILY WATER SEPERATOR
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Accommodation/Occupational Safety
Issued 9 January 1995
Resolved
PRIOR TO NEXT U.S. VOYAGE, CLEAN GREASE BUILD LUP FROM GALLEY EXHAUST VENT AND INSTALL MISSING VENT SCREEN
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Lifesaving
Issued 9 January 1995
Resolved
PRIOR TO NEXT U.S. VOYAGE, PROCURE AND INSTALL WHISTLES AND SOLAS APPROVED LIGHTS ON ALL LIFE JACKETS.
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Electrical
Issued 9 January 1995
Resolved
PRIOR TO NEXT U.S. VOYAGE, PROCURE AND INSTALL EXPLOSION PROOF LIGHTING_x001C_ FIXTURES IN THE PAINT LOCKER (BOSN STORES).
Condition: Unknown
Due 9 April 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 9 January 1995
Resolved
PRIOR TO DEPARTURE FROM THE PORT OF HOUSTON, PROVIDE CLASS SOCIETY SURVEY REPORT ON CONDITION AND RECOMMENDATIONS OF REPAIRS TO MACHINERY IN ENGINEROOM
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Fire Fighting
Issued 9 January 1995
Resolved
PRIOR TO NEXT U.S. VOYAGE, PROVIDE (2) TWO SOLAS APPROVED FLASHLIGHTS (TORCHES) FOR THE FIREMAN'S OUTFITS.
Condition: Unknown
Due 9 April 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 9 January 1995
Resolved
PRIOR TO NEXT U.S. VOYAGE, PROCURE NEW/CURRENT SOLAS BOOK.
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Navigation
Issued 9 January 1995
Resolved
PRIOR TO NEXT U.S. VOYAGE, PROVIDE COMPLETE INFORMATION ON THE MANEUVERING CHARACTERISTICS SHEET ON THE BRIDGE.
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Electrical
Issued 9 January 1995
Resolved
PRIOR TO DEPARTURE FROM THE PORT OF HOUSTON, PROCURE AND INSTALL MISSING LIGHTS AND LIGHT COVERS IN THE ENGINEROOM.
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Lifesaving
Issued 26 May 1994
Resolved
REPLACE BROKEN LIGHTING IN ( PAINT LOCKER ) WITH APPROVED- TYPE EXPLOSION-_x001C_PROOF LAMPS PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Fire Fighting
Issued 26 May 1994
Resolved
PRIOR TO NEXT U.S. PORT PROVIDE PROPER FIRE EXTINGUISHER (ITEM MISSING) IN_x001C_PAINT LOCKER COMPARTMENT AREA.
Condition: Unknown
Due 28 May 1994
Resolved 31 May 1994
Fire Fighting
Issued 26 May 1994
Resolved
PRIOR TO DEPARTURE PROVIDE CLASS SOCIETY REPORT ATTESTING TO THE SATISFACTORY SERVICING OF ALL FIRE EXTINGUISHERS AND EXTINGUISHING SYSTEM.
Condition: Unknown
Due 28 May 1994
Resolved 31 May 1994
Fire Fighting
Issued 26 May 1994
Resolved
PRIOR TO DEPARTURE PROVIDE CLASS SOCIETY REPORT ATTESTING TO THE REPLACEMENT OF THE FOLLOWING: FIRE HOSE NOZZELES (3 MISSING) FIREMANS PORT-ABLE TORCHES AND AXES.
Condition: Unknown
Due 28 May 1994
Resolved 31 May 1994
Navigation
Issued 26 May 1994
Resolved
PROVIDE DOCUMENTATION THAT BRIDGE GLASS (CENTER POSITION) HAS BEEN SATISFACTORY REPLACED,
Condition: Unknown
Due 26 May 1994
Resolved 26 May 1994
Navigation
Issued 26 May 1994
Resolved
PRIOR TO DEPARTURE DEMONSTRATE SATISFACTORY OPERATION OF STEERING AND ALARMS FROM STEERING COMPARTMENT.
Condition: Unknown
Due 28 May 1994
Resolved 31 May 1994
Navigation
Issued 26 May 1994
Resolved
PRIOR TO DEPARTURE PROVIDE CLASS SOCIETY REPORT ATTESTING TO THE SATISFACTORY OF LOCAL [name withheld] OF LOADING CARGO THAT_x001C_ PREVENTS ACCESS TO STEERING COMPARTMENT WHILE IN TRANSIT.
Condition: Unknown
Due 28 May 1994
Resolved 31 May 1994
Documentation
Issued 15 June 1993
Resolved
NO VESSEL SHALL USE ANY PORT OR PLASE IN, OR THE NAVIGABLE WATERS OF, THE UNITED STATES, UNLESS THAT VESSEL HAS A CERTIFICATE COVERING THAT VESSEL AND ITS OPERATOR.
Condition: Unknown
Due 15 June 1993
Resolved 15 June 1993
Documentation
Issued 15 June 1993
Resolved
VESSEL NOT MANNED IN ACCORDANCE WITH SAFE MANNING CERTIFICATE.
Condition: Unknown
Due 15 June 1993
Resolved 15 June 1993