Records from 2015 to 2026. Most recent: inspection, 12 August 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 August 2026
No resolution recorded
A Certificate of Inspection may be suspended and withdrawn or revoked by the cognizant OCMI at any time for noncompliance with the requirements of this subchapter. Subject vsl missed first annual causing the COI to be invalid. Prior to pax, a COI inspection must be conducted on vessel.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 April 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections including operation of the main propulsion machinery both ahead and astern. While conducting operational testing vessels port engine would not engage the propulsion system astern or ahead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2025
Resolution: witnessed propulsion ahead and astern at dock
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 April 2025
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station:
1.) A light to indicate discharge; 2.) audible alarm
3.) Be capable of manual activation from outside the space. 4.) Demonstrate over ride capability.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 21 April 2025
Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. Deck aft of the helm station was not watertight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2025
Resolution: received work repair reciept from Derecktors Shipyard - uploadedin documents
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 21 April 2025
Resolved
For fixed-gas fire extinguishing systems,...The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. No servicing report was provided for vessels pre-engineered fixed fire fighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2025
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 21 April 2025
Resolved
Any vessel of at least five net tons which engages in coastwise trade, must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. No COD present.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 April 2025
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Life jackets had incorrect vessel name marked on all life jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 April 2025
Resolved
Each floating water light installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. The clip must have a strength of at least 22.7 kilograms (50 pounds), and allow the water light to be quickly disconnected from the ring life buoy. Vessel had permanently attached water light arrangements.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 June 2025
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 21 April 2025
Resolved
The frame or support of each semi-portable fire extinguisher...must be welded or otherwise permanently attached to a bulkhead or deck. MI's found portable fire extinguishers with no bracket, frame or support.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 June 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 April 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Vessels first aid kit was incomplete, and did not meet 46 CFR 199 requirements.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 April 2025
Resolved
If more than one ring life buoy is carried, at least one must not have a lifeline attached. Vessel had two ring bouys with attached lifelines.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 June 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 April 2025
Resolved
Strong and effective rudder stops must be provided to prevent jamming and damage to the rudder and its fittings. These stops may be structural or internal to the main steering gear. No rudder stops were present.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 June 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 April 2025
Resolved
Drug testing programs required by this part must be conducted in accordance with 49 CFR part 40. Vessel representative is required to schedule a DAPI audit with the local OCMI/Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 June 2025
Resolution: DAPI Audit completed as of 06JUN25. See documents tab for further.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 21 April 2025
Resolved
A public address system...can be heard throughout the accommodation spaces of the vessel during normal operating conditions, to the satisfaction of the cognizant [name withheld] address system was inoperable aft of the helm station.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 June 2025
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 April 2025
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices...must be corrected and all required guards and protective devices must be in satisfactory condition. Stern gate pin was of inadequate size and strength causing a safety hazard to passengers and crew.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 June 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 April 2025
Resolved
Nonmetallic hose may be used for wet exhaust systems provided it is...and is double clamped where practicable. Port and starboard exhaust had leaks, and
missing double hose clamps.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 June 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 21 April 2025
Resolved
A hatch exposed to the weather must be watertight. All hatches leaked at the center "o-ring". Additionally the forward hatch gasket leaked. All hatches were not watertight.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 July 2025
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 April 2025
Resolved
Rules in this subpart (Rules 20-31) (§§ 83.20 through 83.31) shall be complied with in all weathers. Vessels masthead light was an all-around light.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 June 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 April 2025
Resolved
Each combination solid stream and water spray fire hose nozzle required to be approved under the provisions of this subpart must be of brass or bronze. Vessel fire hose nozzle was plastic.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 June 2025
Operations/Management › Equipment Service/Testing › EPIRB
Issued 10 April 2017
Resolved
Provide EPRIB
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 April 2017
Resolved 10 April 2017
Resolution: Vessel provided EPRIB
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 10 April 2017
Resolved
Provide alcohol test equipment
Action required: 705 - Other - as specified
Due 24 April 2017
Resolved 18 April 2017
Resolution: Vessel provided alcohol test equipment
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 10 April 2017
Resolved
Provide 11 adult lifejackets. Vessel is limited to 84 total persons
Action required: 705 - Other - as specified
Due 24 April 2017
Resolved 18 April 2017
Resolution: Vessel provided lifejackets
Navigation › Piloting/Steering › US Coast Pilot
Issued 10 April 2017
Resolved
Provide updated navigation publications
Action required: 705 - Other - as specified
Due 24 April 2017
Resolved 18 April 2017
Resolution: Vessel provided updated publications
Engineering › Bilge Water Management System › Interface Detector
Issued 25 May 2016
Resolved
Replace bilge alarm panel ack switch
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 8 June 2016
Resolution: Vessel replaced panel
Fire Fighting › Fire Main › Valves
Issued 25 May 2016
Resolved
Replace/Repair fire pump deck valve
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 8 June 2016
Resolution: Vessel replaced valve
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 25 May 2016
Resolved
Provide working ring buoy floating light. Vessel limited to daylight operation.
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 8 June 2016
Resolution: Vessel replaced battery and tested satisfactory.
Engineering › Bilge Water Management System › Pump
Issued 25 May 2016
Resolved
Repair / Remove bilge submersible pump in E/R. Pump is in excess of what's required.
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 8 June 2016
Resolution: Vessel repaired pump
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 25 May 2016
Resolved
Provide fixed system service report attesting siren was satisfactory tested.
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 8 June 2016
Resolution: Vesel provided report.