Records from 2016 to 2020. Most recent: inspection, 14 August 2020.
Documentation record
Registered dimensions (L × B × D)62.0 ft × 13.2 ft × 7.5 ft
Registered tonnagegross 41 / net 32
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSUB SEA SYSTEMS, INC. · RANCHO CORDOVA CA, UNITED STATES · built 1994
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSAIPAN, MP
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it41 - Simplified, Gross Ton
32 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Documentation › Certificates/Documents › FCC SSL
Issued 13 May 2018
Resolved
Vessel must have valid FCC Station License as required by 46 CFR 80. Provide CG proof of valid FCC station license.
Due 31 May 2018
Resolved 15 May 2018
Fire Fighting › Fire Bucket › Availability
Issued 13 May 2018
Resolved
Vessel must have at least three (2 1/2 gallons) buckets with attached lanyard stenciled with words "FIRE BUCKET" as required by 46CFR181.610. Replace missing fire buckets on board.
Due 31 May 2018
Resolved 15 May 2018
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 13 May 2018
Resolved
Vessel must have charts and nautical publication for intended voyage as required by 46CFR184.420. Replace missing Notice to Mariners and Inland Navigation Rules.
Due 31 May 2018
Resolved 15 May 2018
Communications › Public Address System › Loudspeaker
Issued 13 May 2018
Resolved
Vessel must be equipped with public address system as required by 46CFR184.610. Show proper operation of the PA system to CG inspector.
Due 31 May 2018
Resolved 15 May 2018
Lifesaving › Lifebuoys › Serviceable
Issued 22 August 2016
Resolved
Ring life buoy must be in serviceable condition as required by 46 CFR 180.70. Replace damaged life ring.
Due 29 August 2016
Resolved 26 August 2016
Documentation › Certificates/Documents › Certificate of Inspection
Issued 22 August 2016
Resolved
COI must be posted under glass or suitable transparent material as required by 46 CFR 176.302. Post vessel current COI.
Due 30 August 2016
Resolved 26 August 2016
Documentation › Certificates/Documents › FCC SSL
Issued 22 August 2016
Resolved
VSL must have up-to-date FCC station license as required by 47 CFR 80. Provide proof of FCC Station license.
Due 30 August 2016
Resolved 26 August 2016
Documentation › Logs/Records › Logbook (official)
Issued 22 August 2016
Resolved
All drills conducted at least quarterly must be logged as required by 46 CFR 185.420. Provide up-to-date crew training log.
Due 30 August 2016
Resolved 26 August 2016
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 22 August 2016
Resolved
All fire fighting extinguishers must be service annual as required by NFPA. Proved proof of annual services conducted on portable fire fighting extinguishers and FGFE.
Due 30 August 2016
Resolved 26 August 2016
Electrical › Electric Generation Source (service) › Generator
Issued 2 April 2016
Resolved
Alterations to machinery must not be made without the approval of the OCMI as required by 46 CFR 176.700. Owner removed vessel generator without notifying the CG. all electrical equipment on main switch board are OOC including air condition unit. Install generator as original, coordinate installation and operational test with CG.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2016
Resolution: Generator was installed IAW original plan. Electrical load test with A/C system was sat.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 2 April 2016
Resolved
Found exhaust soot through out the aft engine room compartment. Exhaust gas must not leak from the exhaust piping or any connection as required by 46 CFR 182.430. Repair damaged exhaust pipe as original.
Due 12 April 2016
Resolved 3 May 2016
Electrical › Electric Supply System (service) › Battery Installation
Issued 2 April 2016
Resolved
Batteries must be mount in trays lined with material resistant to electrolyte as required by 46 CFR 183.350. Found port battery for propulsion engine stored in the bilge. Stored battery in a proper tray.
Due 19 April 2016
Resolved 3 May 2016
Engineering › Fuel Oil Service System › Filter
Issued 2 April 2016
Resolved
Fuel filter must be fitted with steel bowl that is highly resistant to shattering as required by 46 CFR 182.455(b)(6). Port fuel racor filter is missing protective bowl. Install proper steel bowl.
Due 19 April 2016
Resolved 3 May 2016
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 2 April 2016
Resolved
all exposed hazard such as rotating machinery must be properly protected with cover or guard as required by 46 CFR 177960. Missing cover on exposed port and STDB main Shafts. Install shafts covers.
Due 19 April 2016
Resolved 3 May 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 April 2016
Resolved
Each wire connection must be made within an enclosure as required by 46 CFR 183.340. Fixture light on the entrance missing protective cover. Install the corect enclosure cover.
Due 19 April 2016
Resolved 3 May 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 April 2016
Resolved
Vessel must have navigation light that are in compliance with Navigation Rules as required by 46 CFR 183.420. Both running light are of white color. Replace exiting running lights with CG approved red and green lights.
Due 19 April 2016
Resolved 3 May 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Air Cleaner
Issued 2 April 2016
Resolved
Propulsion machinery must be installed and capable operating in a safe conditions as required by 46 CFR 182.200. Both propulsion engines have air filter saturated with Lents and oil. Replace air filters with in-kind filters.
Due 19 April 2016
Resolved 3 May 2016
Engineering › Fuel Oil Service System › Pump
Issued 2 April 2016
Resolved
All fire hazard must be corrected as required by 46 CFR 176.830. Small diesel leak on port propulsion engine prime pump with fuel saturate rug. repair fuel leak and remove fuel saturated rug.
Due 19 April 2016
Resolved 3 May 2016
Engineering › Sea-water System (primary cooling) › Piping
Issued 2 April 2016
Resolved
All flexible hose designed for use with hose clamps must have hose clamps at both ends of the hose as required by 46 CFR 182.715. Found several hoses missing hose clamps. Install hose clamps on all identified hoses with no clamps.
Due 19 April 2016
Resolved 3 May 2016