Documentation record
Registered dimensions (L × B × D)46.5 ft × 14.3 ft × 6.1 ft
Registered tonnagegross 27 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY CRAFT, INC · LOREAUVILLE, LA, UNITED STATES · built 1993
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 10 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it27 - Simplified, Gross Ton
21 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 20 inspections, each with its date, unit and type; 16 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 20
8 May 2026
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8369337
30 October 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8256424
18 March 2025
COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8084002
25 July 2024
Annual Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7949750
5 July 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7980488
15 August 2023
Annual Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7769157
9 June 2022
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7443943
19 October 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7327214
15 June 2021
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7206704
8 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108291
12 March 2020
COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6916445
16 September 2019
Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6812977
2 July 2019
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6720350
9 July 2018
Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6473279
8 April 2018
Type not recorded
No type recorded · Station Venice · USCG Heartland District (CGD-H) · Activity 6387490
5 September 2017
Examination of Repairs · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6256142
3 August 2017
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6229529
6 April 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6118818
28 June 2016
Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5917456
15 February 2016
Type not recorded
No type recorded · Station Venice · USCG Heartland District (CGD-H) · Activity 5815411
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 March 2025
Resolved
Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI found that the main service generator winding were covered in an excessive buildup of grease and dirt, posing a significant fire hazard. Make proper cleaning to the satisfaction to the attending MI.
46 CFR 183.200
16C
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2025
Resolved 19 March 2025
Resolution: Photos provided of cleaned generator winding. See photos.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 March 2025
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. MI observed the vessel's port side navigation light was inoperative, posing a safety hazard. Replace/make repairs to the port side navigation light to the satisfaction to the attending MI.
46 CFR 183.420
16C
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2025
Resolved 19 March 2025
Resolution: Photos provided of newly installed port side nav light. See attached photos.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 July 2024
Resolved
In systems and applications where flexible hoses are permitted to be clamped, double hose clamping is required where practicable. Attending MI found unapproved hose clamp configuration on generator fuel line.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2024
Resolution: MI attended vessel and inspected satisfactory repairs including: double hose clamping on fuel line.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 25 July 2024
Resolved
A hatch cover must:(1) Have securing devices; and(2) Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Attending MI discovered captive hatch chain for lazarette hatch not connected to vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2024
Resolution: MI attended vessel and inspected satisfactory repairs including: captive chain properly connected to vessel and hatch.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 July 2024
Resolved
Materials used in piping systems must meet the requirements of this subpart and be otherwise acceptable to the cognizant [name withheld] discovered essential system failure of overboard bilge valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2024
Resolution: MI attended vessel and inspected satisfactory repairs including:overboard bilge vale was replaced in kind.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 July 2024
Resolved
The exhaust pipe cooling water system must comply with the requirements of this paragraph. Attending MI discovered main diesel engine exhaust water leaking into engine room in the vicinity of vessel electrical systems.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2024
Resolution: MI attended vessel and inspected satisfactory repairs including: water leak corrected with seal replacement.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 July 2024
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. You must contact the cognizant OCMI to schedule an inspection at a time and place which he or she approves. Vessel failed to contact OCMI to undergo annual inspection prior to 12JUN2024.
Action required: 705 - Other - as specified
Resolved 25 July 2024
Resolution: Annual inspection completed. See activity # 7947950 for details.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 31 October 2023
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel Missed 3rd annual inspection window.
Action required: 10 - Deficiency Rectified
Resolved 31 October 2023
Resolution: Conducted annual inspection
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 June 2021
Resolved
Each life preserver carried on a vessel after June 30, 1980, must have at least 200 sq. cm of retroreflective material attached on its front side, at least 200 sq. cm on its backside, and at least 200 sq. cm of material on each of its reversible sides. 03 life preservers have retroreflective material that is no longer serviceable. Replace retroflective material on life preservers to the satisfaction of the USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2021
Resolution: New retroreflective tape was added to 3 life jackets.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 15 June 2021
Resolved
A hatch exposed to the weather must be watertight. The gasket on the forward hatch of the vessel had a one inch gap and showed signs of deterioration. Replace gasket on forward hatch to the satisfaction of the USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2021
Resolution: Replaced old gasket with a new gasket.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 June 2021
Resolved
Generators and motors designed for 40 degrees Celsius may be used in 50 degree Celsius ambient locations provided the machines are derated to 80 percent of full load rating, and the rating or setting of the overcurrent devices is reduced accordingly. An additional nameplate specifying the derated capacity shall be provided for each such motor and generator. The generator is currently rated for 40 degrees Celsiusand operates in an ambient climate of 50 degrees Celsius. Provide documentation that the generator has been derated and a load analysis demonstrating the generator is capable of meeting the ships current load to the satisfaction of the USCG Marine Inspector. Provide documentation of load analysis prior to running the generator while operating with the air conditioners.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 June 2021
Resolution: Provided documentation from a certified marine electrician stating the Super Runner's existing generator has more than enough load capacity for all circuits on the vessel. See attached documentation.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 15 June 2021
Resolved
In general, compliance with the standards established by a recognized classification society will be considered satisfactory evidence of the structural adequacy of a vessel. There is a cracked weld on the port aft engine mount. Repair to the satisfaction of the USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2021
Resolution: Repaired cracked weld.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 June 2021
Resolved
Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines, one at the tank connection which shall be operable from from outside the tank compartment. The fuel remote shut off valve was heavily corroded. Replace to the satisfaction of the USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2021
Resolution: Replaced valve handle.
Electrical › Electric Supply System (service) › Battery Installation
Issued 28 June 2016
Resolved
Port and starboard battery bank covers are not attached to battery box and present a chaffing hazard to cables. Secure battery covers to eliminate movement.
Action required: 705 - Other - as specified
Due 12 July 2016
Resolved 12 July 2016
Resolution: Battery covers secured.
Lifesaving › Lifefloat › Approval
Issued 28 June 2016
Resolved
6 man lifefloat missing decal for type, manufacture, approval. Replace lifefloat with approved type. Reduced total persons onboard to 24 due to onboard lifefloat capacity.
Action required: 705 - Other - as specified
Due 12 July 2016
Resolved 12 July 2016
Resolution: Replaced 6 man life float.
Lifesaving › Lifefloat › Float-free Link
Issued 28 June 2016
Resolved
Float free link painted over and unreadable. Replaced on the spot.
Action required: 705 - Other - as specified
Due 28 June 2016
Resolved 28 June 2016
Resolution: Replaced on the spot.