Records from 1993 to 2026. Most recent: inspection, 8 May 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 44
8 May 2026
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8369337
30 October 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8256424
18 March 2025
COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8084002
25 July 2024
Annual Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7949750
5 July 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7980488
15 August 2023
Annual Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7769157
9 June 2022
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7443943
19 October 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7327214
15 June 2021
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7206704
8 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108291
12 March 2020
COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6916445
16 September 2019
Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6812977
2 July 2019
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6720350
9 July 2018
Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6473279
8 April 2018
Type not recorded
No type recorded · Station Venice · USCG Heartland District (CGD-H) · Activity 6387490
5 September 2017
Examination of Repairs · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6256142
3 August 2017
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6229529
6 April 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6118818
28 June 2016
Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5917456
15 February 2016
Type not recorded
No type recorded · Station Venice · USCG Heartland District (CGD-H) · Activity 5815411
5 August 2015
Internal Structural Exam · Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5206613
19 March 2014
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4818546
8 May 2012
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4299400
19 July 2011
Examination of Repairs · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4078812
21 July 2009
Hull Examination · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3540361
26 March 2009
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3434092
3 April 2008
Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3174622
31 May 2007
Administrative Inspection · Deficiency Check · Hull Examination · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2937509
24 April 2006
Examination of Repairs · Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2632411
13 April 2005
Hull Examination · COI Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2331137
5 October 2004
Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2208453
15 September 2003
Hull Examination · Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1905189
6 September 2002
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1670811
21 June 2001
Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1459716
7 July 2000
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1384499
23 July 1999
Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1408345
10 July 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1372297
1 July 1997
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1441248
26 September 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1409575
29 November 1995
Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1446279
29 October 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 115979
27 October 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1358587
7 December 1993
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1158121
4 August 1993
Initial Construction-Excluding Oversight · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1428250
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 March 2025
Resolved
Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI found that the main service generator winding were covered in an excessive buildup of grease and dirt, posing a significant fire hazard. Make proper cleaning to the satisfaction to the attending MI.
46 CFR 183.200
16C
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2025
Resolved 19 March 2025
Resolution: Photos provided of cleaned generator winding. See photos.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 March 2025
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. MI observed the vessel's port side navigation light was inoperative, posing a safety hazard. Replace/make repairs to the port side navigation light to the satisfaction to the attending MI.
46 CFR 183.420
16C
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2025
Resolved 19 March 2025
Resolution: Photos provided of newly installed port side nav light. See attached photos.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 July 2024
Resolved
In systems and applications where flexible hoses are permitted to be clamped, double hose clamping is required where practicable. Attending MI found unapproved hose clamp configuration on generator fuel line.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2024
Resolution: MI attended vessel and inspected satisfactory repairs including: double hose clamping on fuel line.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 25 July 2024
Resolved
A hatch cover must:(1) Have securing devices; and(2) Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Attending MI discovered captive hatch chain for lazarette hatch not connected to vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2024
Resolution: MI attended vessel and inspected satisfactory repairs including: captive chain properly connected to vessel and hatch.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 July 2024
Resolved
Materials used in piping systems must meet the requirements of this subpart and be otherwise acceptable to the cognizant [name withheld] discovered essential system failure of overboard bilge valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2024
Resolution: MI attended vessel and inspected satisfactory repairs including:overboard bilge vale was replaced in kind.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 July 2024
Resolved
The exhaust pipe cooling water system must comply with the requirements of this paragraph. Attending MI discovered main diesel engine exhaust water leaking into engine room in the vicinity of vessel electrical systems.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2024
Resolution: MI attended vessel and inspected satisfactory repairs including: water leak corrected with seal replacement.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 July 2024
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. You must contact the cognizant OCMI to schedule an inspection at a time and place which he or she approves. Vessel failed to contact OCMI to undergo annual inspection prior to 12JUN2024.
Action required: 705 - Other - as specified
Resolved 25 July 2024
Resolution: Annual inspection completed. See activity # 7947950 for details.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 31 October 2023
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel Missed 3rd annual inspection window.
Action required: 10 - Deficiency Rectified
Resolved 31 October 2023
Resolution: Conducted annual inspection
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 June 2021
Resolved
Each life preserver carried on a vessel after June 30, 1980, must have at least 200 sq. cm of retroreflective material attached on its front side, at least 200 sq. cm on its backside, and at least 200 sq. cm of material on each of its reversible sides. 03 life preservers have retroreflective material that is no longer serviceable. Replace retroflective material on life preservers to the satisfaction of the USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2021
Resolution: New retroreflective tape was added to 3 life jackets.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 15 June 2021
Resolved
A hatch exposed to the weather must be watertight. The gasket on the forward hatch of the vessel had a one inch gap and showed signs of deterioration. Replace gasket on forward hatch to the satisfaction of the USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2021
Resolution: Replaced old gasket with a new gasket.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 June 2021
Resolved
Generators and motors designed for 40 degrees Celsius may be used in 50 degree Celsius ambient locations provided the machines are derated to 80 percent of full load rating, and the rating or setting of the overcurrent devices is reduced accordingly. An additional nameplate specifying the derated capacity shall be provided for each such motor and generator. The generator is currently rated for 40 degrees Celsiusand operates in an ambient climate of 50 degrees Celsius. Provide documentation that the generator has been derated and a load analysis demonstrating the generator is capable of meeting the ships current load to the satisfaction of the USCG Marine Inspector. Provide documentation of load analysis prior to running the generator while operating with the air conditioners.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 June 2021
Resolution: Provided documentation from a certified marine electrician stating the Super Runner's existing generator has more than enough load capacity for all circuits on the vessel. See attached documentation.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 15 June 2021
Resolved
In general, compliance with the standards established by a recognized classification society will be considered satisfactory evidence of the structural adequacy of a vessel. There is a cracked weld on the port aft engine mount. Repair to the satisfaction of the USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2021
Resolution: Repaired cracked weld.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 June 2021
Resolved
Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines, one at the tank connection which shall be operable from from outside the tank compartment. The fuel remote shut off valve was heavily corroded. Replace to the satisfaction of the USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2021
Resolution: Replaced valve handle.
Electrical › Electric Supply System (service) › Battery Installation
Issued 28 June 2016
Resolved
Port and starboard battery bank covers are not attached to battery box and present a chaffing hazard to cables. Secure battery covers to eliminate movement.
Action required: 705 - Other - as specified
Due 12 July 2016
Resolved 12 July 2016
Resolution: Battery covers secured.
Lifesaving › Lifefloat › Approval
Issued 28 June 2016
Resolved
6 man lifefloat missing decal for type, manufacture, approval. Replace lifefloat with approved type. Reduced total persons onboard to 24 due to onboard lifefloat capacity.
Action required: 705 - Other - as specified
Due 12 July 2016
Resolved 12 July 2016
Resolution: Replaced 6 man life float.
Lifesaving › Lifefloat › Float-free Link
Issued 28 June 2016
Resolved
Float free link painted over and unreadable. Replaced on the spot.
Action required: 705 - Other - as specified
Due 28 June 2016
Resolved 28 June 2016
Resolution: Replaced on the spot.
Documentation › Logs/Records › Logbook (official)
Issued 19 March 2014
Resolved
Vessel needs to provide logs for lifesaving, EPIRB, and services IAW 46 CFR 185.720, 46 CFR 185.728. Re-inspect at next COI inspection.
Due 6 April 2015
Resolved 6 April 2015
Resolution: Provided logs for lifesaving, EPIRB, and services IAW 46 CFR 185.720 and 46 CFR 185.728.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 19 March 2014
Resolved
Vessel needs to update EAP phone numbers IAW 46 CFR 16.401.
Action required: 705 - Other - as specified
Resolved 20 March 2014
Resolution: EAP phone numbers updated.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 19 March 2014
Resolved
Vessel needs to make repairs to the distribution panel so that it can close completely.
Action required: 705 - Other - as specified
Resolved 20 March 2014
Resolution: Distribution panel was repaired so that it can close completely.
Engineering › Diesel Engine (propulsion-electric) › Gear/Clutch Starter (electric)
Issued 19 March 2014
Resolved
Vessel needs to replace missing plug on stbd engine starter.
Action required: 705 - Other - as specified
Resolved 19 March 2014
Resolution: Vessel replaced the missing plug on the stbd engine starter.
Engineering › Steam System (main) › Lagging/Insulation
Issued 19 March 2014
Resolved
Vessel needs to replace lagging in the engine room.
Action required: 705 - Other - as specified
Resolved 20 March 2014
Resolution: Lagging was replaced in the engine room.
Engineering › Generator (propulsion-electric) › Battery
Issued 19 March 2014
Resolved
Vessel needs to provide a cover for batteries in the engine room IAW 46 CFR 183.350, 46 CFR 183.352.
Due 24 March 2014
Resolved 20 March 2014
Resolution: Covers provided for the batteries in the engine room.
Engineering › Generator (propulsion/auxiliary-electric) › Contactor
Issued 7 June 2007
Resolved
Replace generator exhaust lagging in lazerette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 June 2007
Resolved
Remove wires with bitter ends underneath operating station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 June 2007
Resolved
Properly secure engine gauge wires running from operating station to engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 May 2007
Resolved
Install thru bulkhead fitting in forward engine room bulkhead. Replace grommets in remaining fittings.
Due 30 June 2007
Resolved 12 June 2007
Lifesaving › Lifefloat › Float-free Link
Issued 31 May 2007
Resolved
Replace weak link on sea painter for life floats.
Due 30 June 2007
Resolved 12 June 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 31 May 2007
Resolved
Replace wing nuts on batteries with machine nuts.
Due 30 June 2007
Resolved 12 June 2007
Construction/Loadline › Hull › Hull Plating
Issued 31 May 2007
Resolved
Complete required hull exam.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2007
Construction/Loadline › Structures › Machinery Space Opening
Issued 27 April 2006
Resolved
Provide a means to secure engine compartment hatches to the deck.
Action required: 705 - Other - as specified
Due 27 May 2006
Resolved 28 April 2006
Resolution: Repaired engine compartment hatch retaining devices.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 27 April 2006
Resolved
Provide a means to secure starboard vent closure device to inhibit air entry into engine compartment.
Action required: 705 - Other - as specified
Due 27 May 2006
Resolved 28 April 2006
Resolution: Added retaining pin to ventilation closure.
Construction/Loadline › Hull › Hull Plating
Issued 27 April 2006
Resolved
Permanently repair hole and fracture located on the stern deck in way of the transom.
Action required: 705 - Other - as specified
Due 27 May 2006
Resolved 28 April 2006
Resolution: Patch welded repair to gunwale half-pipe.
Construction/Loadline › Hull › Hull Plating
Issued 27 April 2006
Resolved
Permanently repair hole located on starboard quarter rub rail.
Action required: 705 - Other - as specified
Due 27 May 2006
Resolved 28 April 2006
Resolution: patch welded repair to gunwale half-pipe.
Construction/Loadline › Hull › Side Shell
Issued 27 April 2006
Resolved
Permanently repair hole on port sideshell in way of bridge door latch.
Action required: 705 - Other - as specified
Due 27 May 2006
Resolved 28 April 2006
Resolution: Repaired hole on port sideshell and added a strike plate.
Electrical › Electric Supply System (service) › Cable
Issued 27 April 2006
Resolved
Remove excess electrical cable to bilge alarm in steering compartment.
Action required: 705 - Other - as specified
Due 27 May 2006
Resolved 27 May 2006
Resolution: Excess electrical cable was removed and bilge alarm tested as working properly.
Fire Fighting › Fire Bucket › Stenciling
Issued 27 April 2006
Resolved
Properly label three fire buckets.
Action required: 705 - Other - as specified
Due 27 May 2006
Resolved 28 April 2006
Resolution: Fire buckets properly labeled.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 27 April 2006
Resolved
Properly insulate port/starboard exhaust piping.
Action required: 705 - Other - as specified
Due 27 May 2006
Resolved 27 May 2006
Resolution: Insulation on exhaust piping was properly installed.
Fire Fighting › Ventilation Systems › Ducts
Issued 27 April 2006
Resolved
Replace flame screen on starboard fuel vent.
Action required: 705 - Other - as specified
Due 27 May 2006
Resolved 28 April 2006
Resolution: Replaced flame screen.
Communications › Visual Communication › Signalling Lamp
Issued 27 April 2006
Resolved
Properly install engine exhaust overheating light indicators on operational panel.
Action required: 705 - Other - as specified
Due 27 May 2006
Resolved 28 April 2006
Resolution: Repaired engine exhaust overheating indicating lights.
Documentation
Issued 4 August 1993
Resolved
OBTAIN AND PLACE ON BOARD A FCC RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 4 August 1993
Resolved 4 August 1993