Inspection history · 69
5 May 2026
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8367643
30 July 2025
Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8198945
2 June 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8151490
8 May 2025
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8123692
11 December 2023
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7837808
18 September 2023
COI Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7794248
26 October 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7584468
21 October 2021
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7337246
18 May 2021
Internal Structural Exam · Underwater Inspection in lieu of Drydock · Cargo Tank Internal
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7207076
22 October 2020
Deficiency Check · Periodic Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7082695
23 October 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6836954
4 October 2018
COI Inspection · Internal Structural Exam · Drydock Exam · Cargo Tank Internal · Examination of Repairs · Deficiency Check · MTSA Verification · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6546211
12 October 2017
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6284283
18 October 2016
Administrative Inspection · Periodic Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6063626
8 June 2016
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5900732
18 May 2016
Internal Structural Exam · Administrative Inspection · Underwater Inspection in lieu of Drydock
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5880024
14 October 2015
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5758924
23 June 2015
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5161502
26 November 2014
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5030368
29 October 2014
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5021448
15 October 2014
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5003044
17 October 2013
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4736541
11 October 2013
COI Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4731654
4 October 2013
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4729332
9 September 2013
Cargo Tank Internal · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4710581
18 October 2012
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4462946
11 October 2011
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4255432
21 October 2010
Periodic Inspection · MTSA Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3868716
14 October 2008
Cargo Tank Internal · MTSA Verification · Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3331210
10 October 2007
Annual Inspection · MTSA Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3077293
11 October 2006
MTSA Verification · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3077288
6 June 2006
Internal Structural Exam · Underwater Inspection in lieu of Drydock · Cargo Tank Internal
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2623479
15 May 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2649663
27 January 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2574441
4 November 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2528162
13 October 2005
MTSA Verification · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2565028
9 May 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2352971
27 October 2004
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2228949
15 June 2004
MTSA Verification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2080228
29 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1980932
6 November 2003
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1939786
8 October 2003
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1928518
22 September 2003
Hull Examination · Cargo Tank Internal · Internal Structural Exam
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1906547
24 February 2003
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1749313
17 January 2003
Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1710750
17 January 2002
Administrative Inspection · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1473941
29 June 2001
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1067127
21 June 2001
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1384802
19 January 2001
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1449409
21 January 2000
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1404902
2 February 1999
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 791030
29 January 1999
Re-Inspection · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1386438
23 September 1998
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1442745
22 January 1998
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1442658
10 February 1997
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1416439
21 June 1996
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1360559
21 May 1996
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1084859
25 January 1996
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1449891
7 December 1995
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1186223
15 November 1995
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1185097
1 November 1995
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1377540
14 September 1995
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1392302
17 May 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355233
6 March 1995
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1205919
14 October 1994
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1380098
17 September 1993
Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1458115
15 September 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 93673
13 August 1993
Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 847340
22 July 1993
Deadweight Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1155073
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 May 2025
Resolved
Reverse-power and reverse-current trips. Each generator arranged for parallel operation must have reverse-power or reverse-current trips. Vessel reverse-power or reverse-current trips for parallel operations failed. Prove proper operation of these trips to the satisfaction of the attending Marine Inspector.
46 CFR 111.12-11(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2025
Resolved 1 July 2025
Resolution: Witnessed satisfactory operation of the vessel's generators in parallel and testing of the vessel's generator reverse power relays.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 8 May 2025
Resolved
Each hose must be marked with one of the following: for oil products, the words “OIL SERVICE" and the maximum allowable working pressure. The hoses onboard for oil products were not marked with the words “OIL SERVICE" or the maximum allowable working pressure.. Mark a prescribed by the regulation to the satisfaction of the attending Marine Inspector.
33 CFR 154.500(e)
Action required: 10 - Deficiency Rectified
Due 8 May 2025
Resolved 8 May 2025
Resolution: The words “OIL SERVICE" and the maximum allowable working pressure were marked on the hoses onboard for oil products prior to the conclusion of the inspection to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 November 2023
Resolved
Any tank vessel equipped with an internal combustion engine driven cargo pump on the weather deck shall be provided with a minimum of one remote manual shutdown station. The remote quick acting manual shutdown shall be installed on the engine to provide quick and effective means of stopping the engine. Require test of cargo pump shutdowns prior to cargo ops.
46 CFR 32.50-35 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2023
Resolution: Vessel conducted sat shutdowns of cargo pumps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 November 2023
Resolved
Reverse-power and reverse-current trips. Each generator arranged for parallel operation must have reverse-power or reverse-current trips. Vessel unable to demonstrate reverse-current protection. Demonstrate reverse-current protection.
46 CFR 111.12(f)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2023
Resolution: Vessel demonstrated sat test of reverse current protection on #1 and #2 generator.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 November 2023
Resolved
The owner, master, or person-in-charge of a tank vessel must ensure that portable and semi-portable extinguishers are inspected and maintained in accordance with NFPA 10. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Fire extinguishers had been serviced, as evidenced by their tags; however, the complement servicing records were not available during inspection. Provide current fire servicing records.
46 CFR 31.10-18
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 November 2023
Resolution: Vessel provided fire servicing records.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 26 October 2022
Resolved
Each generator arranged for parallel operation must have reverse power or reverse current trips. Vessel could not demonstrate reverse power trip for #1 and #2 generator, due to #2 generator being inoperable. Schedule marine inspector attendance to witness testing.
46 CFR 111.12-11(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 November 2022
Resolution: Tested reverse power trip satisfactorily.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 22 October 2020
Resolved
All cargo tank hatches must be clearly marked in not less than three inch lettering "Danger-Keep Out." and all hatch covers must be closed and dogged down in such a way that the hatch cannot be opened by the use of bare hands alone. 05 of the cargo hatch dogging devices were lose and need to be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2020
Resolved 12 November 2020
Resolution: 05 cargo hatch dogging devices were replaced in-kind.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 11 October 2018
Resolved
All tank vessels of 150 gross tons or over 79 feet in length navigating the oceans/coastwise waters are subject to regulations in parts 42 to 45, inclusive, subchapter E (Load lines). Vessel's Load Line Certificate is expired.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 November 2018
Resolved 1 November 2018
Resolution: Load line Certificate issued by ABS.
01 - Certificates & Documentation › 013 - Documents › Survey report file
Issued 11 October 2018
Resolved
The owner, operator or master shall provide the OCMI with all current valid certificates and registers of cargo gear issued by competent person or a recognized organization to certify the suitability of the cargo gear. Annual cargo gear inspection was not conducted prior to this inspection. Previous cargo gear inspection conducted over one year ago.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2018
Resolved 1 November 2018
Resolution: Cargo gear certificate issued by ABS.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 11 October 2018
Resolved
An oil record book shall be maintained by the master of the vessel. Each completed operation shall be signed by the person or persons in charge of the operations concerned and each completed page shall be signed by the master. Oil record book found without signature of the person in charge of operations after each entry.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2018
Resolved 23 October 2018
Resolution: Training provided to personnel for oil record book entries.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 11 October 2018
Resolved
An oil record book shall contain entries for the disposal of oil residue from machinery spaces and cargo tanks. The amounts recorded in the oil record book for offloading oil residue do not match the receipt provided
by the shore reception facility on Sept. 25, 2017.
Action required: 10 - Deficiency Rectified
Due 11 October 2018
Resolved 11 October 2018
Resolution: Operator provided education for oil record book entries. Verified amount discharged from the vessel with shore reception facility.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 11 October 2018
Resolved
Oil transfer procedures shall include procedures for reporting discharges of oil or hazardous material into the water. Telephone numbers found in transfer procedures lead to disconnected numbers. Oil transfer procedures shall include cargo information as described in 33 CFR 154.310(a)(5)(ii). Found an outdated format for MSDS dated June 1985 for cargo information. Provide amendment for transfer procedures in accordance with 33 CFR 155.760.
Action required: 703 - Prior to bunkering operations
Due 11 November 2018
Resolved 26 October 2018
Resolution: Oil transfer procedures submitted to USCG for review. Examined.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 October 2018
Resolved
Lifejackets must be fitted with type I retro-reflective material approved under approval series 164.018. 16 lifejackets required to be on-board. 6 lifejackets found out of compliance with type I retro-reflective tape requirements.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 November 2018
Resolved 23 October 2018
Resolution: 16 lifejackets found onboard complying with subchapter W.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 October 2018
Resolved
Operator was not prepared to test machinery shutdowns on auxiliary machinery. Make auxiliary machinery low lube, high temperature, and overspeed alarms available for inspection.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 November 2018
Resolved 23 October 2018
Resolution: Machinery shutdowns tested on two aux generators and two prime movers for cargo pump hydraulics.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 October 2018
Resolved
Three non-metallic expansion joints on machinery coolant piping found with physical damage atop the machinery space, starboard side. Replace damaged non-metallic expansion joints.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 November 2018
Resolved 26 October 2018
Resolution: Operator replaced three non-metallic expansion joints on machinery coolant piping atop the machinery space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 October 2018
Resolved
Operator was not prepared to test relief valves located on the piping for the two compressors located in the machinery space. Provide relief valve verification for the settings indicated to relieve pressure.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 November 2018
Resolved 23 October 2018
Resolution: Relief valves for compressors tested satisfactory at 250 psi.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 October 2018
Resolved
Starting battery for generator found with a severed conductor creating resistance at the battery terminal. Repair or replace conductor.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 November 2018
Resolved 23 October 2018
Resolution: Starting battery conductor renewed and found satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 October 2018
Resolved
Ground fault detection for ship's service power system found without an illuminated phase C bulb. Replace bulb and prove satisfactory ground fault detection.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 November 2018
Resolved 23 October 2018
Resolution: Ground fault detection phase C bulb replaced and functioning.
09 - Working and Living Conditions › 092 - Working Conditions › Adequate lighting - mooring arrangements
Issued 11 October 2018
Resolved
Deck light located atop the machinery space, forward on the port side, found with a sheared mounting bolt. The light is hanging by one bolt and creates a danger to personnel on the main deck.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 November 2018
Resolved 26 October 2018
Resolution: Deck light mounted with new hardware.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 11 October 2018
Resolved
Emergency lighting found disconnected. Unable to test emergency lighting throughout the vessel. Connect emergency lighting and conduct satisfactory emergency lighting test.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 November 2018
Resolved 3 December 2018
Resolution: Emergency lighting tested at dead ship and found to be satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 October 2018
Resolved
Pressure vessels found with scale and water inside. Clean pressure vessels for internal inspection. Unable to complete COI until pressure vessels are internally inspected.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 November 2018
Resolved 23 October 2018
Resolution: Pressure vessels cleaned and visually inspected internally.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 18 October 2016
Resolved
Demonstrate proper operation of high temperature alarms for both gensets and both cargo pump prime movers.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 8 November 2016
Resolution: Witnessed proper operation of all high temperature alarms noted in deficiency. All sat.
Lifesaving › Inflatable Liferafts › Servicing
Issued 18 October 2016
Resolved
Provide proof of annual life raft servicing.
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 8 November 2016
Resolution: Verified on board life raft servicing records and inspection sticker. All sat.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 18 October 2016
Resolved
Provide proof of annual class load line/hull & cargo gear surveys.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 8 November 2016
Resolution: Verified Internation load line certificate was endorsed by class, and that annual cargo gear certificate had been issued. All sat.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 18 October 2016
Resolved
Provide proof of cargo pump gauge calibration to verify accuracy is w/in 10%
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 8 November 2016
Resolution: Reviewed and verified records for gauge calibrations. All sat.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 18 October 2016
Resolved
Provide records for servicing/testing of all cargo hoses.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 8 November 2016
Resolution: Reviewed and verified records for hydro testing of all cargo hoses. MAWP of cargo hoses is 200 PSI; records indicated that hydro testing was conducted at 300 psi. All sat.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 18 October 2016
Resolved
Re-clamp high pressure fuel lines from fuel pump to the injectors on #1 and #2 cargo pump prime movers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 8 November 2016
Resolution: Verified missing clamps were replaced and worn out clamping material was renewed. All sat.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 18 October 2016
Resolved
Properly mark all cargo hoses in accordance with 33 CFR 154.500(e) through (g). The hose test pressure must NOT be marked on the the hose.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 11 November 2016
Resolution: Received email with photos showing proper markings on all cargo hoses. All sat.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 October 2016
Resolved
Prove proper operation of navigation lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 8 November 2016
Resolution: Witnessed operation of all navigation lights. All sat.
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 18 October 2016
Resolved
Conduct maintenance of all p/v valves for cargo tanks. Ensure valves operate freely without restriction or sticking.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 8 November 2016
Resolution: Witnessed proper operation of p/v valves for each cargo tank. All sat.
Engineering › Pressure Vessel › Relief Valve
Issued 18 October 2016
Resolved
Clean paint off of all pressure relief valve data placards. Ensure pressure relief valves are not rated highter than the MAWP of the pressure vessel they protect.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 11 November 2016
Resolution: Verified paint has been removed from all pressure relief valve data placards. Received photos of new placards indicating the actual operating set point of 250 psi for each pressure relief valve for the ships air system (4 valves total).
Engineering › Pressure Vessel › Relief Valve
Issued 18 October 2016
Resolved
Demonstrate proper operation of pressure relief valves for each air receiver.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 8 November 2016
Resolution: Witnessed operation of pressure relief valves for both air receivers and associated piping (4 valves total). Ensured valves opened at or below 250 psi (MAWP on air receiver placard). All sat.
Engineering › Pressure Vessel › Piping
Issued 18 October 2016
Resolved
Repair wasted pipe coming off of relief valve for thermal fluid heater expansion tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 8 November 2016
Resolution: Verified wasted pipe had been renewed. All sat.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 18 October 2016
Resolved
Grease intake vent closure assemblies and ensure they close freely; Remove rust scale from intake vents, and remove paint from exhaust vent damper wing bolts, grease bolts and ensure the bolts can be secured freely.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 8 November 2016
Resolution: Verified intake ventilation closures operated freely, rust scale had been removed and paint from exhaust damper wing bolts were renewed and bolts were greased and were easily secured. All sat.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 18 October 2016
Resolved
Provide records of required cargo transfer system piping hydro tests, and testing of cargo transfer piping system relief valves.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 11 November 2016
Resolution: Received records for the cargo transfer piping/manifold and cargo piping relief valve testing. All sat.
Deck/Cargo › Mooring/Anchoring › Anchoring Arrangement
Issued 18 October 2016
Resolved
Prove proper operation of anchor windlass and associated hydraulic equipment.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 8 November 2016
Resolution: Confirmed repairs of anchor windlass and hydraulic system with vessel engineers. All sat.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 14 October 2015
Resolved
Clean or renew flame screens for # 2 and # 4 starboard cargo tanks.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2015
Resolved 26 October 2015
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 14 October 2015
Resolved
Prove proper operation of # 5 port P/V valve - pressure side.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2015
Resolved 26 October 2015
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 14 October 2015
Resolved
Prove proper operation of the emergency light in the MSD space - portside.
Action required: 705 - Other - as specified
Due 14 November 2015
Resolved 26 October 2015
Fire Fighting › Firemans Outfit › Axe
Issued 14 October 2015
Resolved
Provide new fire ax.
Action required: 705 - Other - as specified
Due 14 November 2015
Resolved 26 October 2015
Electrical › Electric Generation Source (service) › Generator
Issued 14 October 2015
Resolved
Prove proper operation of the high jacket water light on the S/S generator alarm panel - # 1 and # 2 S/S generators.
Action required: 705 - Other - as specified
Due 14 November 2015
Resolved 26 October 2015
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 14 October 2015
Resolved
Provide 2 PFD lights.
Action required: 705 - Other - as specified
Due 14 November 2015
Resolved 26 October 2015
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 15 October 2014
Resolved
Crew told USCG marine inspector that the bleach tank was an additional piece of equipment,
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 October 2014
Resolved 16 October 2014
Resolution: Company mgmt provided USCG type approval of bleach tank, attached to documents.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 15 October 2014
Resolved
Non rising stem deck valves do not have valve indicators attached. Currently crew uses rope tied to valves to indicate valves that are closed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 November 2014
Resolved 26 November 2014
Resolution: All valves have indicators
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 15 October 2014
Resolved
Missing certification of cargo piping and guages.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 November 2014
Resolved 16 October 2014
Resolution: Issued company print out of tests
Engineering › Pressure Vessel › Relief Valve
Issued 15 October 2014
Resolved
Safety relief valves do manually lift. Missing certification of recent testing, some labels as old as 1995
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 November 2014
Resolved 16 October 2014
Resolution: Company mgmt provided internal maintenance program that safety relief valves are tested operationally.
Lifesaving › Inflatable Liferafts › Servicing
Issued 15 October 2014
Resolved
Current Liferaft certificate expires this month.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2014
Resolved 29 October 2014
Resolution: Emailed certificate
Personnel › Training › Cargo Safety
Issued 15 October 2014
Resolved
Benzene program was not onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 November 2014
Resolved 16 October 2014
Resolution: Company provided portions of the benzene program, normally the vessel does not responsd to benzene spills nor carry benzene products on a routine basis. All MSRC employees are enrolled in a Benzene and occupational monitoring program.
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 11 October 2013
Resolved
The vessel sent 25 person liferaft to servicing facility for annual inspection. Prior to carrying personnel underway, the vessel shall restow the liferaft onboard.
Action required: 705 - Other - as specified
Resolved 17 October 2013
Lifesaving › Lifebuoys › Stowage
Issued 11 October 2013
Resolved
All ring buoys were stowed with zip ties around the stowage bracket. Prior to carrying personnel underway, the barge shall make all ring buoys readily accessible.
Action required: 705 - Other - as specified
Resolved 17 October 2013
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 11 October 2013
Resolved
All batteries inside battle lanterns were dead. Vessel is to replace all batteries inside battle lanterns inside machinery space.
Action required: 705 - Other - as specified
Due 25 October 2013
Resolved 17 October 2013
Pollution Prevention/Response › Response Equipment › Containers
Issued 11 October 2013
Resolved
Vessel does have discharge removal equipment IAW 33 CFR 155.210. Provide enough discharge removal equipment for an on-deck oil spill of 7 barrels.
Action required: 705 - Other - as specified
Due 25 October 2013
Resolved 17 October 2013
Documentation › Certificates/Documents › International Load Line Certificate
Issued 14 October 2008
Resolved
Provide copies of loadline certificate, cargo gear certificate and classification certificate.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 October 2008
Resolved 23 October 2008
Resolution: Observed copies of valid loadline, cargo gear and class certificates.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 14 October 2008
Resolved
Provide copies of the annual review of the SOPEP and VRP.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 October 2008
Resolved 23 October 2008
Resolution: Observed copies of the annual review for the SOPEP and VRP.
Documentation › Markings/Placards › Warning Signs
Issued 14 October 2008
Resolved
Repair or renew the portside center sign - "Warning no open lights".
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 October 2008
Resolved 23 October 2008
Resolution: Observed new portside center sign.
Engineering › Fuel Oil Service System › Filter
Issued 14 October 2008
Resolved
Replace plastic plugs on the racor filters with metal plugs.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 October 2008
Resolved 23 October 2008
Resolution: Observed new metal plugs in all racor filters.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 14 October 2008
Resolved
Prove proper operation of all alarms and trips, except for high jacket water temp., on # 2 hydraulic pump engine.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 October 2008
Resolved 23 October 2008
Resolution: Observed the proper operation of all alarms and trips on # 2 hydraulic pump engine.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 10 October 2007
Resolved
provide adequate mechanical plugs for all pollution prevention containment systems.
Action required: 705 - Other - as specified
Due 15 November 2007
Resolved 12 October 2007
Deck/Cargo › Cargo Heating › General
Issued 6 June 2006
Resolved
Numerous soft patched were discovered in Heater piping system. Vessel is to make proper repairs to all soft patches and provide a report for all heater piping.
Condition: Unknown
Due 7 July 2006
Resolved 10 October 2007
Resolution: System has been placed out of service
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 October 2004
Resolved
Provide current COI for vessel and post on vessel.
Action required: 705 - Other - as specified
Due 27 November 2004
Resolved 28 October 2004
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 27 October 2004
Resolved
Provide annual review for SOPEP and put in SOPEP.
Action required: 705 - Other - as specified
Due 27 November 2004
Resolved 28 October 2004
Deck/Cargo › Cargo Stowage › General
Issued 27 October 2004
Resolved
Repair or renew the spool piece for #3 cargo tank starboard sounding tube where holed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 October 2004
Resolved 28 October 2004
Deck/Cargo › Cargo Stowage › General
Issued 27 October 2004
Resolved
Clean rust from the spool pieces for the sounding tubes for all cargo tanks as needed. If deteriorated provide repair proposal for the necessary repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 October 2004
Resolved 28 October 2004
Deck/Cargo › Cargo Heating
Issued 8 October 2003
Resolved
Prove operation of the Thermal Fluid heater automation.
Action required: 705 - Other - as specified
Due 8 November 2003
Resolved 6 November 2003
Engineering › Diesel Engine (auxiliary)
Issued 8 October 2003
Resolved
Prove operation of SSDG and hydraulic pump prime mover overspeeds. LEGACY COMPONENT DESC: Overspeed Device
Action required: 705 - Other - as specified
Due 8 November 2003
Resolved 6 November 2003
Engineering › Diesel Engine (auxiliary)
Issued 8 October 2003
Resolved
Prove parallel operation and reverse power relays on the SSDG's.
Action required: 705 - Other - as specified
Due 8 November 2003
Resolved 6 November 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 8 October 2003
Resolved
Properly mark hydrostatic test data on cargo piping. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 8 November 2003
Resolved 6 November 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 8 October 2003
Resolved
Provide H2S warning signs.
Action required: 705 - Other - as specified
Due 8 November 2003
Resolved 6 November 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 8 October 2003
Resolved
Provide unobstructed view of warnings signs.
Action required: 705 - Other - as specified
Due 8 November 2003
Resolved 6 November 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 8 October 2003
Resolved
Install pressure gauge on forward deepwell pump. LEGACY COMPONENT DESC: Cargo Pump
Action required: 705 - Other - as specified
Due 8 November 2003
Resolved 6 November 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 8 October 2003
Resolved
Provide position indicator on forward valve # 1 starboard cargo tank. LEGACY COMPONENT DESC: Closure Devices
Action required: 705 - Other - as specified
Due 8 November 2003
Resolved 6 November 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 17 January 2003
Resolved
Provide benzene warning notice in accordance with 46CFR 197.535(c)
Due 28 February 2003
Resolved 24 February 2003
Resolution: Sighted posted Benzene Warning.
Accommodation/Occupational Safety › Occupational Safety
Issued 17 January 2003
Resolved
Make permanent repair to the eye for rail course located stbd behind aft fender. LEGACY COMPONENT DESC: Deck Rail
Due 28 February 2003
Resolved 24 February 2003
Resolution: Sighted permanent repairs.
Construction/Loadline
Issued 21 June 2001
Resolved
Crop and renew bent/buckled #1 main transverse frame in way of #1 side long(top) outboars in STBD AFT pumproom/sea chest void.
Condition: Unknown
Due 15 July 2001
Resolved 26 June 2001
Documentation
Issued 29 January 1999
Resolved
Post oil transfer procedures at discharge station.
Condition: Unknown
Due 18 February 1999
Resolved 23 February 1999
Engineering
Issued 29 January 1999
Resolved
Repair exhaust leak to #2 generator.
Condition: Unknown
Due 18 February 1999
Resolved 23 February 1999
Documentation
Issued 29 January 1999
Resolved
Provide proper oil record books prior to carrying recovered oil.
Condition: Unknown
Due 18 February 1999
Resolved 23 February 1999
Navigation
Issued 29 January 1999
Resolved
Prove proper operation of amber flashing light. Vessel may not be pushed ahead prior to correction of this requirement.
Condition: Unknown
Due 18 February 1999
Resolved 23 February 1999
Construction/Loadline
Issued 21 June 1996
Resolved
At the next scheduled drydock examination, prepare underwater hull areas bypreparing a marking grid and create a reference video in accordance with NVIC 1-89.
Condition: Unknown
Due 21 June 1996
Resolved 21 June 1996
Engineering
Issued 1 November 1995
Resolved
INSTALL RELIEF VALVE FOR EACH AIR RECEIVER SET TO RELIEVE AT NOT MORE THAN THE RECEIVER'S MAWP._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Engineering
Issued 14 September 1995
Resolved
INSTALL VISUAL AND AUDIBLE LOW LUBE OIL ALARM ON THE 624 HP DIESEL ENGINES.
Condition: Unknown
Due 14 September 1995
Resolved 14 September 1995
Engineering
Issued 14 September 1995
Resolved
INSTALL RELIEF VALVE FOR EACH AIR RECEIVER SET TO RELIEVE AT NOT MORE THAN THE RECEIVER'S MAWP.
Condition: Unknown
Due 14 September 1995
Resolved 14 September 1995
Deck/Cargo
Issued 14 October 1994
Resolved
PROPERLY MARK THE TRANSFER HOSES AS REQUIRED BY 33 CFR 154.500(e) ONCE HYDRO TESTING HAS BEEN COMPLETED.
Condition: Unknown
Due 14 October 1994
Resolved 14 October 1994
Deck/Cargo
Issued 14 October 1994
Resolved
PERFORM HYDRO TEST OF TRANSFER HOSES AS REQUIRED BY 33 CFR 156.170.
Condition: Unknown
Due 14 October 1994
Resolved 14 October 1994
Documentation
Issued 17 September 1993
Resolved
Provide onboard an approved cargo transfer procedure IAW 33 CFR 155.720. Vessel may not carry cargo until this requirement is met._x001C_
Condition: Unknown
Due 17 September 1993
Resolved 17 September 1993