Records from 1993 to 2026. Most recent: inspection, 30 April 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 49
30 April 2026
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8352704
30 April 2025
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8111630
14 January 2025
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8063221
6 May 2024
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7904817
5 July 2023
Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7733289
19 April 2023
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7671493
12 January 2023
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7618387
27 May 2022
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7459679
3 June 2021
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7214023
25 January 2021
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7130099
1 May 2020
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6944635
1 July 2019
Type not recorded
No type recorded · Station Indian River · USCG East District (CGD-E) · Activity 6731346
10 May 2019
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6681018
27 February 2019
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6633744
30 April 2018
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6411795
22 May 2017
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6152433
18 April 2017
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6131624
23 May 2016
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5887543
9 June 2014
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 4883760
14 May 2012
Administrative Inspection
Administrative · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 4264368
30 August 2011
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 4130070
16 June 2008
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3238539
11 June 2007
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2957996
18 April 2007
Hull Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2909500
9 May 2006
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2647350
7 December 2005
Type not recorded
No type recorded · Violation Case Coordination Center · Activity 2547497
21 August 2005
Type not recorded
No type recorded · Station Indian River · USCG East District (CGD-E) · Activity 2474515
19 May 2005
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2351203
21 April 2005
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2339090
18 May 2004
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2070931
2 April 2003
Periodic Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1859794
20 November 2002
Administrative Inspection
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1708139
20 June 2002
Type not recorded
No type recorded · Station Indian River · USCG East District (CGD-E) · Activity 1634263
25 March 2001
Annual Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1373583
19 May 2000
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1453761
17 May 1999
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1471196
19 April 1999
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1413513
11 May 1998
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1125773
15 April 1998
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1451285
9 July 1997
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 779061
2 July 1997
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 780922
1 May 1997
Hull Examination · COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1103478
2 July 1996
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1095363
2 May 1995
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 867389
24 April 1995
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1148213
8 February 1995
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1146491
26 July 1994
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1176087
3 September 1993
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1151555
3 August 1993
Initial Certification · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1156150
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 April 2026
Resolved
Repairs or alterations to the machinery or equipment must not be made without prior approval from the OCMI. New generator found to be installed on the vessel. Submit an electrical diagram for the generator to include the generator, load, wire gauge, overcurrent protection. Submit specs sheet for the newly installed generator and the generator that was removed. 46CFR176.700
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2026
Resolution: Electrical plan and spec sheet for both generators received. In kind replacement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 April 2026
Resolved
Each generator for use in a machinery space must be designed for an ambient temperature of 50 degrees C. Generator installed is rated for 40 degrees C. Prove machinery space is designed to operate below 40C or de-rate the generator to 80% and ensure overcurrent protection does not exceed 15% above full-load rating. Provde proof by updated nameplate and or technical report. Vessel is not permitted to use the generator until this deficiency is cleared.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 11 June 2026
Resolution: Name plate provided from manufacturer that proved generator was de-rated from 10 kw to 8.5 and overcurrent protection verfified on electrical plan not to exceed 15% the full load rating.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 April 2025
Resolved
Spaces such as spaces with machinery shall have interconnected detection system iaw 46CFR181.450. E/R missing interconnected smoke detector. 46CFR181.405
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2025
Resolution: Verified interconnected smoke detector purchased and installed.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 30 April 2025
Resolved
Marine employers shall have means of chemical testing. Vsl has 02 alcohol swabs, 04 are required. 46CFR185.212
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 15 May 2025
Resolution: MI verified 02 additional alcohol testing swabs were ordered and placed on board.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 30 April 2025
Resolved
EPIRB with float free arrangement required on vessels operating beyond 3NM from the coastline. Hydro release is expired. Vsl restricted to operating within 3NM from shore. 46CFR180.64
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 May 2025
Resolution: Verified new hydrostatic release placed onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 30 April 2025
Resolved
Life floats shall have life lines secured around the sides. Life lines are deteriated and require replacement. 46CFR180.15-1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 May 2025
Resolution: O/O replaced life float life lines with new lines.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 May 2020
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each space identified in this cite. The visual indicators for the E/R and bunk room activate the same high level alarm. 46 CFR 182.530
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2020
Resolved 4 May 2020
Resolution: Verified proper operation of high level indicators at operating station.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 May 2020
Resolved
Pre-engineered fixed gas fire extinguishing system must automatically shut down all engines. The stbd engine hunted during system test and did not shut down in a timely period. 46 CFR 181.420
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2020
Resolved 4 May 2020
Resolution: Verified proper operation of stbd engine shut-down.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 9 June 2014
Resolved
Provide FCC Safety Radio certificate.
Due 9 July 2014
Resolved 1 July 2014
Resolution: FCC Safety Radio Certificate provided.
Lifesaving › Lifefloat › Float-free Link
Issued 30 August 2011
Resolved
Properly install life float weak link.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2011
Resolution: Weak link installed properly.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 30 August 2011
Resolved
Install and test Fireboy bottle and system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2011
Resolution: Examined and tested Fireboy bottle and system satisfactorily.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 16 June 2008
Resolved
no members of crew had enrollment cards available.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 27 June 2008
Resolution: proof of enrollment was provided.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 June 2008
Resolved
wires in E/R are not retained properly 24 inch.
Action required: 705 - Other - as specified
Due 16 August 2008
Resolved 27 June 2008
Resolution: all wires properly retained.
Engineering › Sea-water System (primary cooling) › Piping
Issued 16 June 2008
Resolved
exhaust piping has rubber hose inserts that have developed dry rot.
Action required: 705 - Other - as specified
Due 16 September 2008
Resolved 27 June 2008
Resolution: hose was replaced properly.
Engineering › Sea-water System (primary cooling) › Valve
Issued 16 June 2008
Resolved
sb engine raw water intake valve handle broke off during inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2008
Resolution: recieved call from captain stating that the valve has been completely replaced, i will inspected 30JUN2008.
Engineering › Bilge Water Management System › Interface Detector
Issued 16 June 2008
Resolved
e/r high level alarm broke durring inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2008
Resolution: high level alarm replaced op checked all sat.
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 June 2008
Resolved
port side battery box have improper cable routing causing box cover to not close properly.
Action required: 705 - Other - as specified
Due 16 September 2008
Resolved 27 June 2008
Resolution: Battery box closes properly.
Fire Fighting › Fire Bucket › Availability
Issued 16 June 2008
Resolved
only two were available.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2008
Resolution: additional fire bucket provided.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 16 June 2008
Resolved
water light not properly attached.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2008
Resolution: water light now properly attached.
Lifesaving › Lifefloat › Float-free Link
Issued 16 June 2008
Resolved
weak link does not have persons rating and approval tag.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2008
Resolution: tag now made available.
Personnel › Training › First Aid/CPR
Issued 16 June 2008
Resolved
no cpr or first aid cards were available.
Action required: 705 - Other - as specified
Due 23 June 2008
Resolved 27 June 2008
Resolution: all cards were now available.
Lifesaving › Lifefloat › Serviceable
Issued 16 June 2008
Resolved
life float deteriorating shall be replaced by 01 Nov 2008.
Action required: 705 - Other - as specified
Due 1 November 2008
Resolved 5 June 2009
Resolution: life float replaced with new life float 15 man.
Engineering
Issued 15 April 1998
Resolved
REPLACE ORANGE HOSE ON OIL FILL SYSTEM WITH C.G. APPROVED HOSE AND FITTING.
Condition: Unknown
Due 15 April 1998
Resolved 15 April 1998
Accommodation/Occupational Safety
Issued 15 April 1998
Resolved
LABEL MSD VALVE "DO NOT DDISCHARGE IN U. S. WATERS.
Condition: Unknown
Due 15 April 1998
Resolved 15 April 1998
Lifesaving
Issued 15 April 1998
Resolved
PROVIDE INVENTORY LIST AND WIRE SPLINT FOR FIRST AID KIT.
Condition: Unknown
Due 15 April 1998
Resolved 15 April 1998
Lifesaving
Issued 1 May 1997
Resolved
TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR CONDUCT A MAN OVERBOARD DRILL.
Condition: Unknown
Due 13 May 1997
Resolved 13 May 1997
Lifesaving
Issued 3 August 1993
Resolved
Provide shackles in the lines attaching the lifefloat to the weaklink and the weaklink to the deck.
Condition: Unknown
Due 27 September 1993
Resolved 27 September 1993
Lifesaving
Issued 3 August 1993
Resolved
Provide a copy of the 406 EPIRB registration receipt. The route is restricted to coastwise not more than 20 miles from a harbor of safe refuge.
Condition: Unknown
Due 27 September 1993
Resolved 27 September 1993
Documentation
Issued 3 August 1993
Resolved
Provide a copy of the permanent FCC Operator's License._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 September 1993
Resolved 27 September 1993
Lifesaving
Issued 3 August 1993
Resolved
Provide additional ring buoy and light attached to the life float. Passenger carriage for oceans route is limited to not more than 13 total persons.
Condition: Unknown
Due 27 September 1993
Resolved 27 September 1993