MAURY USCG vessel records Sign in
← All vessels

ODYSSEY

ODYSSEY is a 1993 passenger vessel (inspected). The Coast Guard has recorded 64 inspections since 1993, most recently in June 2026, along with 56 deficiencies — 3 with no resolution recorded — and 1 operational control.

Records from 1993 to 2026. Most recent: inspection, 18 June 2026.

Built
1993
Last inspected
18 June 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9000699 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
391076
Flag
BAHAMAS, THE
—
Maury page id
psix-391076

Inspections, by type

…with no type recorded15
…past their stated due date3
Years with a record 12 calendar years (1993–2026)
The 64 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it19089 - Regulatory (Subpart C or D), Gross Ton
19089 - Convention (Subpart B), Gross Ton
8103 - Regulatory (Subpart C or D), Net Ton
8103 - Convention (Subpart B), Net Ton
19089 - Dead Weight, Ton
11047 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 64

18 June 2026 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8410803
16 December 2025 PSC B · COC-CVE Quarterly
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8278742
23 June 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8165475
20 June 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8163202
2 June 2025 Administrative Inspection · PSC A · COC-CVE Initial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8148520
9 April 2025 COC-CVE Initial
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8108941
11 December 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3378274
10 December 2008 In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3377757
13 November 2008 ISPS II Exam · COC-CVE Initial · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Activities Europe · Activity 3318845
9 October 2002 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1687865
7 October 2002 MARPOL Annex V Examination · Certificate of Compliance · MARPOL Annex I Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1683918
25 October 2000 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 283265
9 August 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 282978
9 August 2000 Quarterly Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1055377
30 May 2000 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 23472
10 May 2000 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 276801
10 May 2000 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1393425
10 May 2000 Control Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1417059
1 December 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 435348
1 December 1999 Control Verification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 812297
20 October 1999 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1125342
3 September 1999 Control Verification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1361088
25 June 1999 Quarterly Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1381636
21 April 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 427795
10 March 1999 MARPOL Annex I Examination · Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1411830
13 January 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 424133
9 January 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 5385
11 December 1998 MARPOL Annex I Examination · Quarterly Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1378525
19 October 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 802825
16 October 1998 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 803347
28 September 1998 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 801796
18 September 1998 MARPOL Annex I Examination · Control Verification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1381341
17 July 1998 Quarterly Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1455610
5 May 1998 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 790741
5 April 1998 Control Verification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1414969
8 August 1997 Quarterly Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1383661
3 May 1997 Control Verification · MARPOL Annex I Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1433190
8 February 1997 Quarterly Examination · MARPOL Annex I Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1385902
14 December 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1390401
2 November 1996 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1359289
31 July 1996 MARPOL Annex I Examination · Quarterly Examination · MARPOL Annex V Examination · Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1367880
27 April 1996 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1357587
24 February 1996 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1396451
25 November 1995 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1363423
6 September 1995 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 883870
6 September 1995 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 884351
30 August 1995 Control Verification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 882691
30 August 1995 Quarterly Examination · MARPOL Annex I Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1377521
26 May 1995 Deficiency Check · Control Verification · MARPOL Annex I Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1403957
1 April 1995 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1175429
17 December 1994 Quarterly Examination · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1171065
5 September 1994 Control Verification
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 863814
13 June 1994 Control Verification
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1178886
30 April 1994 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 858669
22 February 1994 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1163697
29 January 1994 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1163817
30 October 1993 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1470082
16 October 1993 Certificate of Compliance · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1144298
16 October 1993 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1162718
3 September 1993 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 360650
27 August 1993 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 515032
22 July 1993 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 499115
17 July 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1152333
15 July 1993 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 842316

Deficiency record · 56

14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 2 June 2025 Resolved
No person may operate any vessel equipped with installed toilet facilities unless it is equipped with an operable Type device. The installed device does not operate. 33CFR159.7 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2025
Resolved 18 June 2026
Resolution: System repaired. DNV statement provided.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 2 June 2025 No resolution recorded
General arrangement plan shall be permanently exhibited for the guidance of the ship's officers. Plans shall be kept up to date. The current plan needs to be approved by MSC. 74 SOLAS 20 II-2/20.1 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2025 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 2 June 2025 No resolution recorded
Each passenger stateroom and crew cabin shall be equipped with entry doors that include peepholes or other means of visual identification. There are no means of visual identification on any of the vessel's entry doors. 46USC(a)(1)(B) 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2025 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 June 2025 Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and between such spaces and the weather decks, all openings shall be provided with permanently atached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. The fire boundary door from the Neptune Lounge to the Dress Room is not effective for resisiting fires. 74 SOLAS 81 Amend II-2/30.1 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2025
Resolved 16 December 2025
Resolution: Fired door was replaced with proper door
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 June 2025 No resolution recorded
Spaces other than public spaces, corridors, public toilets, special category spaces, othr stairways required by regulation 28.1.5, open deck spaces and spaces covered by paragraph 4.4.2 are not permitted to have direct access to stairway enclosures. The 01 Deck engineering workshop in Main Vertical Zone 4 has direct access to escape stairs. 74 SOLAS 97 II-2/41-2.4.5 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2025 — due date passed with no resolution recorded
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 7 October 2002 Resolved
PAST DUE SERVICE FOR CO2 EXTINGUISHERS AND FIXED CO2. SOLAS 74 I-7 LEGACY COMPONENT DESC: Tanks
Condition: Improper/Lack of Maintenance
Due 8 October 2002
Resolved 9 October 2002
Resolution: Received servicing technicians report.
Navigation
Issued 3 September 1999 Resolved
EMERGENCY STEERING DRILLS WERE NOT CONDUCTED OR LOGGED IN PAST 3 MONTHS PER33 CFR 164.25.
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Fire Fighting
Issued 3 September 1999 Resolved
SMOKE DETECTORS WERE MISSING FROM LOCKER #704 AND FROM ADJACENT LOCKER.
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Lifesaving
Issued 25 June 1999 Resolved
OIL FILM ON DECK IN STEERING GEAR ROOM PRESENTS A SLIP/FALL HAZARD TO CREW.-ILO 147
Condition: Unknown
Due 21 July 1999
Resolved 21 July 1999
Fire Fighting
Issued 10 March 1999 Resolved
Provide documentaion that bottom of lift trunk in crew laundry is a A-Classboundry at frames 143-145 no later than 10APR99.
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Fire Fighting
Issued 10 March 1999 Resolved
Provide response to Marine Safety Center Ltr. dated 16DEC98, in reference to pantry on deck 4 having direct access to stairtower, no later than 10APR99.
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Fire Fighting
Issued 10 March 1999 Resolved
Provide documentation in reguards to the integrity of the bulkhead to the cruise director and bar managers office. Remove filing cabinet in corridor no later than 10APR99.
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Fire Fighting
Issued 11 December 1998 Resolved
Effect repairs to fire screen door #130 to attain proper closure IAW SOLAS 74 II-2/47 prior to 11JAN99.
Condition: Unknown
Due 11 December 1998
Resolved 11 December 1998
Fire Fighting
Issued 11 December 1998 Resolved
Remove combustibles from the aft stairtower IAW SOLAS 74 II-2/34 prior to 11JAN99.
Condition: Unknown
Due 11 December 1998
Resolved 11 December 1998
Construction/Loadline
Issued 11 December 1998 Resolved
Effect repairs to the #2 port condenser overboard discharge valve IAW ICll prior to 09NOV99.
Condition: Unknown
Due 11 December 1998
Resolved 11 December 1998
Fire Fighting
Issued 28 September 1998 Resolved
Remove combustible material from forward stairtower on deck #2.
Condition: Unknown
Due 29 September 1998
Resolved 29 September 1998
Documentation
Issued 18 September 1998 Resolved
Provide updated cover letter for SOPEP IAW MARPOL I Reg 26.
Condition: Unknown
Due 18 September 1998
Resolved 18 September 1998
Documentation
Issued 18 September 1998 Resolved
Provide documentation from vsl's flag state which inbdicates acceptance of home flag of current officer's license.
Condition: Unknown
Due 18 September 1998
Resolved 18 September 1998
Documentation
Issued 18 September 1998 Resolved
Resolve through class society comments in MSC letter H2-9800821 dated 18MAR98 with regard to RFSA.
Condition: Unknown
Due 18 September 1998
Resolved 18 September 1998
Electrical
Issued 17 July 1998 Resolved
Improperly installed 110 wolt electric cable in laundry room.
Condition: Unknown
Due 17 July 1998
Resolved 3 August 1998
Lifesaving
Issued 5 April 1998 Resolved
Lifejacket boxes on bow improperly labeled. Properly label prior to next U.S. port call (to satisfaction of attending DNV surveyor).
Condition: Unknown
Due 5 April 1998
Resolved 5 April 1998
Accommodation/Occupational Safety
Issued 5 April 1998 Resolved
Starboard forward showroom escape door does not open. Repair and prove operation at next U.S. port of call (to satisfaction of attending DNV surveyor).
Condition: Unknown
Due 5 April 1998
Resolved 5 April 1998
Accommodation/Occupational Safety
Issued 5 April 1998 Resolved
Crew laundry dryer vent ducts clogged with excessive lint. Clean and reattach ducting prior to use. Complete to satisfaction of attending DNV surveyor.
Condition: Unknown
Due 5 April 1998
Resolved 5 April 1998
Fire Fighting
Issued 5 April 1998 Resolved
Bridge indicators for fire doors nos. 513,126,238,605 inoperative. Repair and demonstrate proper operation to satisfaction of attending DNV surveyor prior to next U.S. port call.
Condition: Unknown
Due 5 April 1998
Resolved 5 April 1998
Lifesaving
Issued 3 May 1997 Resolved
Properly deploy a 25 person inflatable liferaft taken from the vessels complement at the 1st Quarterly Examination. To be completed in the presence of a USCG Marine Inspector.
Condition: Unknown
Due 3 May 1997
Resolved 3 May 1997
Construction/Loadline
Issued 2 November 1996 Resolved
Class to provide statement attesting to the proper interaction/operation ofthe damage control valves by ships computer and the pneumatic remote control station.
Condition: Unknown
Due 2 November 1996
Resolved 2 November 1996
Lifesaving
Issued 2 November 1996 Resolved
Repair navigation lights on lifeboats #6, #7 and #8.
Condition: Unknown
Due 2 November 1996
Resolved 2 November 1996
Lifesaving
Issued 2 November 1996 Resolved
Remove lifejackets from lifeboats and stow lifejackets in deck stowage containers.
Condition: Unknown
Due 2 November 1996
Resolved 2 November 1996
Fire Fighting
Issued 31 July 1996 Resolved
Prove positive latch closure mechanism on FSD's 006, 121, 118, 124.
Condition: Unknown
Due 15 August 1996
Resolved 16 August 1996
Fire Fighting
Issued 31 July 1996 Resolved
Prove proper operation of local release mechanism on FSD 015.
Condition: Unknown
Due 15 August 1996
Resolved 16 August 1996
Electrical
Issued 27 April 1996 Resolved
REPAIR THE INDICATOR PANEL FOR THE WATERTIGHT DOORS LOCATED ON THE DECK ABOVE SO THAT THE RED LIGHTS GO OUT COMPLETELY WHEN THE DOORS ARE CLOSED
Condition: Unknown
Due 27 April 1996
Resolved 27 April 1996
Fire Fighting
Issued 27 April 1996 Resolved
REPAIR OR REPLACE THE LATCHING MECHANISM ON FSD # 120 LOCATED IN THE BOILERROOM
Condition: Unknown
Due 27 April 1996
Resolved 27 April 1996
Fire Fighting
Issued 24 February 1996 Resolved
THE TEST PIPING ON SPRINKLER TEST STATION # 21 WAS CLOGGED BY RUSTY WATER
Condition: Unknown
Due 24 February 1996
Resolved 24 February 1996
Fire Fighting
Issued 24 February 1996 Resolved
THE SIGN ON THE OUTSIDE OF SPRINKLER TEST STATION # 21 WAS MISSING
Condition: Unknown
Due 24 February 1996
Resolved 24 February 1996
Fire Fighting
Issued 24 February 1996 Resolved
FSD # 320 NEEDS TO BE ADJUSTED SO THAT IT WILL LATCH PROPERLY WHEN CLOSED FROM THE BRIDGE
Condition: Unknown
Due 24 February 1996
Resolved 24 February 1996
Fire Fighting
Issued 25 November 1995 Resolved
TWO FIRE SCREEN DOORS WOULD NOT CLOSE WHEN RELEASED FROM THE BRIDGE
Condition: Unknown
Due 25 November 1995
Resolved 26 November 1995
Lifesaving
Issued 25 November 1995 Resolved
MANY OF THE CREW'S LIFE JACKETS HAVE A LIGHT WHICH HAS TWO LONG BLUE BATTERIES FOR POWER. THESE BATTERIES WILL EXPAND IF ANY MOISTURE GETS IN THE PORTS AND ONCE THEY START TO EXPAND, THE LIGHT WILL NO LONGER FUNCTION.
Condition: Unknown
Due 25 November 1995
Resolved 26 November 1995
Fire Fighting
Issued 30 August 1995 Resolved
_x001C_ Prove proper operation of the following fire screen doors: 704, 702 (does not open properly), 215, 273 (local switches inop.), 201 (permanently remove or modify ramp)
Condition: Unknown
Due 30 August 1995
Resolved 30 August 1995
Lifesaving
Issued 30 August 1995 Resolved
_x001C_ Remove combustibles from the following areas: Fire equipment locker No. 5 (Valentino's), Bottom of aft passenger stairtower (Boxes)
Condition: Unknown
Due 30 August 1995
Resolved 30 August 1995
Fire Fighting
Issued 30 August 1995 Resolved
_x001C_ Replace horn on CO2 extinguisher 006.
Condition: Unknown
Due 30 August 1995
Resolved 30 August 1995
Fire Fighting
Issued 30 August 1995 Resolved
_x001C_ Prove proper operation of smoke detector 0965.
Condition: Unknown
Due 30 August 1995
Resolved 30 August 1995
Fire Fighting
Issued 30 August 1995 Resolved
_x001C_ Prove proper operation of alarm for sprinkler zone No. 1.
Condition: Unknown
Due 30 August 1995
Resolved 30 August 1995
Fire Fighting
Issued 30 August 1995 Resolved
_x001C_ Purge water from hose at fire station No. 714.
Condition: Unknown
Due 30 August 1995
Resolved 30 August 1995
Fire Fighting
Issued 30 August 1995 Resolved
_x001C_ Prove proper operation of smoke detector 1404.
Condition: Unknown
Due 30 August 1995
Resolved 30 August 1995
Lifesaving
Issued 30 August 1995 Resolved
_x001C_ Remove combustibles in electrical locker across from fire screen door No. 523.
Condition: Unknown
Due 30 August 1995
Resolved 30 August 1995
Fire Fighting
Issued 30 August 1995 Resolved
_x001C_ Prove proper operation of fire dampers L4 and L5.
Condition: Unknown
Due 30 August 1995
Resolved 30 August 1995
Lifesaving
Issued 26 May 1995 Resolved
Prove proper operation of #2 Lifeboat limiter switch.
Condition: Unknown
Due 15 June 1995
Resolved 15 June 1995
Fire Fighting
Issued 26 May 1995 Resolved
Prove proper operation of FSD #403.
Condition: Unknown
Due 15 June 1995
Resolved 15 June 1995
Fire Fighting
Issued 30 April 1994 Resolved
Remove combustibles from under crew stairway #2 adjacent to tailor shop.
Condition: Unknown
Due 2 May 1994
Resolved 2 May 1994
Lifesaving
Issued 30 April 1994 Resolved
Provide embarkation ladders to embarkation decks Port and Starboard._x001C_
Condition: Unknown
Due 2 May 1994
Resolved 2 May 1994
Accommodation/Occupational Safety
Issued 29 January 1994 Resolved
Provide a copy of the training manual for the crew recreation room.
Condition: Unknown
Due 29 January 1994
Resolved 29 January 1994
Documentation
Issued 29 January 1994 Resolved
Paint the starboard side loadline deck line mark in contrasting colors.
Condition: Unknown
Due 29 January 1994
Resolved 29 January 1994
Lifesaving
Issued 30 October 1993 Resolved
STARBOARD SIDE LIFEBOATS HAVE NOT BEEN EXERCISED AS REQUIRED BY SOLAS '74, AS AMENDED, CHAPTER III, REG. 18.3.7.
Condition: Unknown
Due 30 October 1993
Resolved 30 October 1993
Documentation
Issued 30 October 1993 Resolved
PROVIDE DOCUMENTATION FROM THE FLAG ADMINISTRATION AS TO THE REQUIRED NUMBER OF CERTIFICATED LIFEBOATMEN.
Condition: Unknown
Due 30 October 1993
Resolved 30 October 1993
Documentation
Issued 30 October 1993 Resolved
PROVIDE PANAMANIAN LICENSES FOR THE MASTER, CHIEF ENGINEER, SAFETY OFFICER,AND ONE DECK OFFICER OR PROVIDE DOCUMENTATION THAT PANAMA ACCEPTS CANADIAN,ARGENTINE, AND CROATIAN LICENSES.
Condition: Unknown
Due 30 October 1993
Resolved 30 October 1993
Lifesaving
Issued 15 July 1993 Resolved
PROVE PROPER OPERATION OF THE #5 LIFEBOAT ENGINE IN AHEAD AND ASTERN MODES TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO DEPARTING THE PORT OF NEW YORK.
Condition: Unknown
Due 20 July 1993
Resolved 20 July 1993

Ownership record