Records from 2025 to 2026. Most recent: inspection, 18 June 2026.
Documentation record
Tonnage as PSIX records it19089 - Regulatory (Subpart C or D), Gross Ton
19089 - Convention (Subpart B), Gross Ton
8103 - Regulatory (Subpart C or D), Net Ton
8103 - Convention (Subpart B), Net Ton
19089 - Dead Weight, Ton
11047 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Inspection history · 6
18 June 2026
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8410803
16 December 2025
PSC B · COC-CVE Quarterly
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8278742
23 June 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8165475
20 June 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8163202
2 June 2025
Administrative Inspection · PSC A · COC-CVE Initial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8148520
9 April 2025
COC-CVE Initial
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8108941
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 2 June 2025
Resolved
No person may operate any vessel equipped with installed toilet facilities unless it is equipped with an operable Type device. The installed device does not operate. 33CFR159.7 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2025
Resolved 18 June 2026
Resolution: System repaired. DNV statement provided.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 2 June 2025
No resolution recorded
General arrangement plan shall be permanently exhibited for the guidance of the ship's officers. Plans shall be kept up to date. The current plan needs to be approved by MSC.
74 SOLAS 20 II-2/20.1 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2025 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 2 June 2025
No resolution recorded
Each passenger stateroom and crew cabin shall be equipped with entry doors that include peepholes or other means of visual identification. There are no means of visual identification on any of the vessel's entry doors.
46USC(a)(1)(B) 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2025 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 June 2025
Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and between such spaces and the weather decks, all openings shall be provided with permanently atached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. The fire boundary door from the Neptune Lounge to the Dress Room is not effective for resisiting fires.
74 SOLAS 81 Amend II-2/30.1 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2025
Resolved 16 December 2025
Resolution: Fired door was replaced with proper door
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 June 2025
No resolution recorded
Spaces other than public spaces, corridors, public toilets, special category spaces, othr stairways required by regulation 28.1.5, open deck spaces and spaces covered by paragraph 4.4.2 are not permitted to have direct access to stairway enclosures. The 01 Deck engineering workshop in Main Vertical Zone 4 has direct access to escape stairs.
74 SOLAS 97 II-2/41-2.4.5 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2025 — due date passed with no resolution recorded