MAURY USCG vessel records Sign in
← All vessels

JIA XING

JIA XING is a 1992 freight ship. The Coast Guard has recorded 18 inspections since 2001, most recently in September 2016, along with 8 deficiencies and 4 operational controls, 1 with no removal date recorded.

Records from 2001 to 2016. Most recent: inspection, 20 September 2016.

Built
1992
Last inspected
20 September 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

8821955 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
391157
Flag
HONG KONG
—
Maury page id
psix-391157

Inspections, by type

…with no type recorded8
Years with a record 6 calendar years (2001–2016)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it18177 - Convention (Subpart B), Gross Ton
8695 - Convention (Subpart B), Net Ton
21684 - Dead Weight, Ton
31614 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 18

20 September 2016 NPV Safety Exam · ISPS III Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6004976
19 September 2016 Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6004496
11 August 2016 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5969380
8 August 2016 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5966359
8 August 2016 Ballast Water Examination · ISPS III Exam · NPV Safety Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5966383
6 March 2016 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5830106
2 March 2016 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5825824
30 January 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5802223
30 January 2016 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5806380
14 June 2012 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4335772
17 August 2011 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4118464
19 January 2011 MARPOL Annex I Examination · ISPS I Exam · MARPOL Annex V Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3924029
17 January 2011 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3924928
28 September 2010 Ballast Water Examination · ISPS III Exam · PII Safety Exam · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3854728
18 February 2010 Deficiency Check · MARPOL Annex VI Survey · ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3678578
6 October 2005 ISPS II Exam · PII Safety Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2509330
26 October 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 294996
24 October 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 494953

Deficiency record · 8

Navigation › Collision/Grounding Avoidance › Radar
Issued 11 August 2016 Resolved
Secondary X-Band radar was inoperable.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 September 2016
Resolution: Received Class report attesting to proper repairs.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 8 August 2016 Resolved
The vessel's steering gear compartment had a hydraulic leak and has wooden pallets on the deck that are slick, creating a slip and fall hazard.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 September 2016
Resolution: Received class report attesting to installation of hand rails and non slip cushioning.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 8 August 2016 Resolved
Vessel does not have the appropriate means of testing the heat detection system.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 September 2016
Resolution: Received class report attesting to proper thermal detector testers provided on board vessel.
Fire Fighting › Means of Escape › Blocked
Issued 8 August 2016 Resolved
Multiple emergency escape doors in the engine room were tied or wasted shut.
Action required: 705 - Other - as specified
Resolved 8 August 2016
Resolution: Vessel cleared all emergency escape doors for use.
Engineering › Compressed Air System (start air) › Control Gear
Issued 14 June 2012 Resolved
1410-propulsion main engine-No change shall be made in the machinery, equipment and other items covered by the survey. PSCO observed air dryer used for start air system disassembled deeming it inop. Provide clarification from certificate issuing authority attesting to the proper operation/repair of the air dryer, as well as integrity of start air system. 74SOLAS(am) I/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 June 2012
Resolved 23 November 2012
Resolution: Vessel submitted report attesting to the proper repair and operation of the air dryer.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 14 June 2012 Resolved
0899-Other(acid prevent)-Each transfer piping system must not leak under static liquid pressure at least 1.5 times the maximum allowable working pressure. Vessel could not provide documentation attesting to the completion of this test. Provide documentation prior to bunkering in the U.S. 33CFR156.170
Action required: 703 - Prior to bunkering operations
Due 14 June 2012
Resolved 28 June 2012
Resolution: Received, reviewed and accepted proper documentation from Master stating def was rectified.
Lifesaving › Launching Appliances › Winch Brake
Issued 28 September 2010 Resolved
Crew is unable to lower lifeboats according to the vessels SOLAS training manual. The brake wire on the Portside lifeboat launching arrangements has too much slack to lower the life boat with one crew member. other crew members are needed to assist in tending the loose brake wire. The brake wire is also damaged in multiple areas where the wire rests against the pulley system.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 September 2010
Resolution: ABS attended the vessel on behalf of CCS on 29SEP10. Class cleared deficiency as well as lower both lifeboats. Brake release wires and rollers were in good working order.
Fire Fighting
Issued 26 October 2001 Resolved
Provide hydro-static survey report for portable CO2 fire extinguishers or have serviced prior to departure from the port of Mobile, AL. SOLAS 74/78 amended II-2/ 6.5.
Condition: Unknown
Due 26 October 2001
Resolved 30 October 2001

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.