Records from 1993 to 2017. Most recent: inspection, 5 July 2017.
Inspection history · 40
5 July 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6188463
10 June 2012
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4339507
23 January 2012
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4230168
19 December 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3914329
10 October 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3868887
5 September 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3842351
5 September 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3856152
12 July 2009
Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3530497
11 July 2008
Ballast Water Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3264565
13 July 2007
Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2993995
10 July 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2990972
4 May 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2922024
4 May 2007
ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2922106
20 April 2006
MARPOL Annex I Examination · Random ISPS/MTSA/PSC · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2628968
28 October 2005
MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2523762
6 July 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2417814
14 January 2005
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2274741
16 December 2004
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2260292
21 October 2004
NPV Safety Exam · Random ISPS/MTSA/PSC
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2225299
18 May 2004
MTSA/ISPS Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2071413
13 April 2004
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2043100
22 November 2003
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1952502
16 September 2003
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1905968
15 August 2002
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1661752
2 October 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 294290
15 September 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1071336
13 July 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 291788
31 October 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 447471
18 July 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 280025
24 September 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 433074
15 July 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 430731
20 July 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 418278
12 June 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 418289
26 June 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 405152
17 April 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 402766
30 November 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 385420
17 November 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 385056
15 October 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 371461
21 May 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 367346
4 August 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 359935
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 5 July 2017
Resolved
0715 -Fire protection system and fire-fighting syatem and appliances shall be maintained ready for use. PSCO could not verify functionalty of smoke extraction system from the cargo
spaces upon initial request. Electrician made repairs to system, witnessed functional test. 74SOLAS(14) II-2/14.1.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 5 July 2017
Resolution: Deficiency rectified on the spot to the satisfaction of the COAST GUARD
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 12 July 2009
Resolved
Make permanent repairs to compressed air hose line for MSD tank. Red puddy is being used as a temporary hold/bond on top of tank. Make permanent repairs within 30 days to the satisfaction of Class.
Action required: 705 - Other - as specified
Due 12 August 2009
Resolved 11 August 2009
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 July 2009
Resolved
Wasted parts of exhaust lines discovered in both pollution prevention equipment store rooms. Make permanent repairs to hole/wasted spots as well as the top coverings within 30 days to the satisfaction of Class.
Action required: 705 - Other - as specified
Due 12 August 2009
Resolved 11 August 2009
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 12 July 2009
Resolved
When testing oily water separator, discovered only a visual alarm with no audible alarm. Ensure this is a proper alarm arrangement within 30 days to the satisfaction of Class.
Action required: 705 - Other - as specified
Due 12 August 2009
Resolved 11 August 2009
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 4 May 2007
Resolved
Vessel has proximity suits instead of firefighting ( solas approved) suits.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 4 June 2007
Resolved 12 August 2009
Resolution: As per vessel''s email correspondence with Class, the fire suits are approved. Additionally, conducted satisfactory inspection of fire suits.
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 4 May 2007
Resolved
Hand rail on port side is worn and broken in one section due to container ops.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 June 2007
Resolved 12 July 2009
Resolution: Received Class report from 10May2007 that repairs were made.
Lifesaving › Lifeboat › Carriage Requirement
Issued 16 December 2004
Resolved
Vessel missing lifeboat due to heavy weather and poor maintenacne upon lifeboat's lashing. Lifeboat lashing cable heavily corroded and rusted. Cable failed to hold under heavy sea conditions.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 January 2005
Resolved 11 January 2005
Resolution: Lloyds Register witnessed, tested and approved newly installed lifeboat.
Lifesaving › Lifeboat
Issued 16 September 2003
Resolved
Windows for the freefall lifeboat are etched from the salty conditions, vessel to replace the windows. LEGACY COMPONENT DESC: View (at steering position)
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 November 2003
Resolved 22 November 2003
Resolution: WINDOWS FOR THE FREEFALL LIFEBOAT WERE REPLACED AND TESTED TO THE SATISFACTION OF CLASS (LLOYD''S REGISTER) .
Lifesaving
Issued 12 June 1998
Resolved
Provide Class report concerning number of soft patches/leak repairs to saltwater piping in engine room.
Condition: Unknown
Due 12 July 1998
Resolved 20 July 1998
Engineering
Issued 26 June 1997
Resolved
CREW WAS UNABLE TO PROVE PROPER OPERATION OF OWS DUE TO FAILURE IN THE AUTOMATIC DISCHARGE/RE-CIRCULATING VALVE._x001C_ MUST FIX AND SATISFACTORY PROVE PROPER OPERATION OF OWS TO THE ATTENDING MARINE INSPECTOR, PRIOR TO NEXT US PORT.
Condition: Unknown
Due 28 June 1997
Resolved 28 June 1997
Engineering
Issued 17 April 1997
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR IN THE PRESENCE OF CLASS SURVEYOR. PROVIDE FAX COPY OF RESULTS TO MSO MIAMI. MSO MUST APPROVE STATEMENT/PROPOSAL FROM CLASS PRIOR TO DEPARTURE.
Condition: Unknown
Due 17 April 1997
Resolved 18 April 1997
Engineering
Issued 17 April 1997
Resolved
PROVIDE SPARE COALESCING FILTERS FOR OIL WATER SEPARATOR UPON ARRIVAL NEXT U.S. PORT.
Condition: Unknown
Due 26 June 1997
Resolved 26 June 1997
Engineering
Issued 17 November 1995
Resolved
PROVE PROPER OPERATION OF THE OILY WATER SEPERATOR TO THE SATISFACTION OF THE CLASS ADMINISTRATION AND AN ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 30 November 1995
Resolved 30 November 1995