MAURY USCG vessel records Sign in
← All vessels

TESEO

TESEO is a 1993 tank ship. The Coast Guard has recorded 78 inspections since 1993, most recently in February 2010, along with 21 deficiencies and 12 operational controls.

Records from 1993 to 2010. Most recent: inspection, 21 February 2010.

Built
1993
Last inspected
21 February 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9038866 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
391382
Flag
PANAMA
—
Maury page id
psix-391382

Inspections, by type

…with no type recorded44
Years with a record 18 calendar years (1993–2010)
The 78 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it99477 - Dead Weight, Ton
115807 - Displacement, Ton
54827 - Regulatory (Subpart C or D), Gross Ton
29295 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LYNNE MORAN Towing Vessel · MISLE 741035 · 16 August 2006 · activity 2754671

Inspection history · 78

21 February 2010 COE-Administrative
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3683279
6 February 2010 COE-Dockside
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3675898
2 February 2010 COE-Administrative
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3673986
22 December 2009 COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3652981
4 July 2009 COE-Administrative
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3533700
1 May 2009 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3465145
30 April 2009 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3494218
24 April 2009 COE-Administrative
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3459699
9 April 2009 COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3449385
16 March 2009 COE-Dockside
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3434510
26 February 2009 COE-Administrative
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3424341
3 February 2009 COE-Dockside
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3401015
18 January 2009 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3396132
15 December 2008 PII Safety Exam · MARPOL Annex V Examination · ISPS III Exam · Deficiency Check · MARPOL Annex I Examination · COC-TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3378757
23 May 2008 ISPS II Exam · PII Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3211700
4 November 2007 MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3088463
2 October 2007 MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3066487
9 July 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2989859
23 June 2007 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2971014
4 April 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2901374
3 April 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2900448
1 April 2007 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2899421
28 February 2007 Random ISPS/MTSA/PSC
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2879140
30 October 2006 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2810360
16 August 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2754671
9 August 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2741810
25 May 2006 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2658609
25 May 2006 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2658948
4 May 2006 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2664020
8 January 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2563129
8 January 2006 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2594263
29 November 2005 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2540282
10 November 2005 COC-TVE Renew
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2534155
14 July 2005 Random ISPS/MTSA/PSC
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2426716
25 May 2005 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2363965
2 February 2005 NPV Safety Exam
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2285495
13 November 2004 Ballast Water Examination · ISPS III Exam · COC-TVE Annual
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2237546
8 November 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2237103
18 October 2004 NPV Safety Exam
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2223081
15 July 2004 PII Safety Exam
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2134425
2 July 2004 ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2118411
26 February 2004 Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2013490
27 October 2003 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1938538
9 June 2003 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1813434
10 March 2003 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1753960
20 February 2003 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1745358
16 October 2002 Annual Inspection · Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1689910
22 April 2002 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1607797
19 April 2002 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1605280
12 February 2002 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1485171
6 September 2001 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 293468
27 April 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 481873
12 October 2000 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 282853
21 July 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 280243
17 April 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 276876
29 September 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 433195
23 April 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 427743
20 October 1998 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 421402
4 October 1998 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 420937
7 May 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 415940
6 October 1997 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 408648
6 October 1997 Tank Vessel Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 773264
8 February 1997 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 400354
6 January 1997 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 493465
2 October 1996 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 395804
25 April 1996 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 390511
10 April 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 389998
13 September 1995 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 382571
14 August 1995 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 381581
12 September 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 370378
12 September 1994 Tank Vessel Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1463131
11 July 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 497388
16 December 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 363119
24 November 1993 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 691162
13 November 1993 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 108650
14 September 1993 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1146155
13 September 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 360638
13 September 1993 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1410852

Deficiency record · 21

Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 1 May 2009 Resolved
Received notification that the Main Engines Fly Wheel had Malfunctioned. Need Class Report stating all is in good working order. SOLAS (as amended) Chapter II-I Regulation 31.1
Action required: 17 - Rectify deficiencies prior to departure
Due 1 May 2009
Resolved 2 May 2009
Resolution: Received Class survey report stating the Electronic Governing System failed due to misaligned main engine flywheel tachometer pickup units. Units adjusted and cleaned. Bridge and ECR main engine control restored to the satisfaction of Class.
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 15 December 2008 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2008
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 2 October 2007 Resolved
The boatswain's flag state endorsment has expired as Aug 07. To the satisfaction of the administration.
Action required: 705 - Other - as specified
Due 2 November 2007
Resolved 4 November 2007
Resolution: A flag state endorsment has been issued to the boatswain.
Navigation › Collision/Grounding Avoidance › Radar
Issued 9 July 2007 Resolved
Issued inbound Letter of Deviation for an inoperable primary radar. Vessel must provide technician report prior to departure attesting to repairs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2007
Resolution: RCVD sat tech report.
Navigation › Collision/Grounding Avoidance › Radar
Issued 23 June 2007 Resolved
Inbound: (23JUN2007) The vessel was granted a Letter of Deviation to enter the Port of Corpus Christi with an inoperable 3cm (X-Band) Radar. Daylight transit only restriction. Outbound: (27JUN2007) Vessel was unable to rectify the deficiency in this port, Outbound LOD granted. The vessel is still required to request an inbound LOD at future U.S. ports until the equipment is repaired.
Action required: 705 - Other - as specified
Due 18 July 2007
Resolved 2 August 2007
Resolution: Received technician report via fax attesting satisfactory operation of the Marine Radar.
Navigation › Collision/Grounding Avoidance › Radar
Issued 4 April 2007 Resolved
Vessel reported inoperable radar prior to entering the Lower Mississippi River.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2007
Resolution: After review of the tech. report from Sperry Marine, PSC/ Arrivals Branch approved the rescission of restriction and cleared the deficiency.
Deck/Cargo › Holds/Tanks › Cargo Tank Arrangement/Size
Issued 13 November 2004 Resolved
Cargo tanks were found in an underpressure condition and crew was unable to demonstrate proper inert atmosphere in cargo tanks. SOLAS 74(amended) II-2/62
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 November 2004
Resolution: Crew inerted tanks prior to completion of inspection on 13NOV04.
Navigation › Collision/Grounding Avoidance › Radar
Issued 14 July 2004 Resolved
Vessel was issued LOD to enter the Port of Corpus Christi without properly operating secondary radar, 33CFR164.37(a).
Due 17 July 2004
Resolved 17 November 2004
Resolution: RECIEVED TECH REPORT VERIFYING REPAIRS WERE MADE AND EQUIPMENT IS OPERATIONAL.
Documentation › Certificates/Documents
Issued 26 February 2004 Resolved
Classification Document was expired. LEGACY COMPONENT DESC: Classification Document
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 February 2004
Resolved 26 February 2004
Resolution: Recieved updated Classification Document from agent.
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 26 February 2004 Resolved
Safety Construction Certificate was expired.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 February 2004
Resolved 26 February 2004
Resolution: Recieved updated Safety Construction Certificate from agent.
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 26 February 2004 Resolved
Safety Equipment Certificate was expired.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 February 2004
Resolved 26 February 2004
Resolution: Recieved updated Safety Equipment Certificate from agent.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 26 February 2004 Resolved
Safety Radio Certificate was expired.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 February 2004
Resolved 26 February 2004
Resolution: Recieved updated Safety Radio Certificate from agent.
Documentation › Certificates/Documents › IOPP Certificate
Issued 26 February 2004 Resolved
International Oil Pollution Prevention Certificate was expired.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 February 2004
Resolved 26 February 2004
Resolution: Recieved updated IOPP Certificate from agent.
Engineering
Issued 12 October 2000 Resolved
Replace flame screen on port slop tank vent.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Lifesaving
Issued 12 October 2000 Resolved
Replace deteriorated buoyant lifeline on all applicable lifebuoys.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Fire Fighting
Issued 12 October 2000 Resolved
Replace firemans outfit located in foam room in accordance with SOLAS 74 (ammended) CH. II-2 Reg. 17.1.1.1.1.
Condition: Unknown
Due 11 December 2000
Resolved 11 December 2000
Lifesaving
Issued 12 October 2000 Resolved
Properly secure O2 bottle in hospital space and replace safety cap.
Condition: Unknown
Due 17 October 2000
Resolved 17 October 2000
Navigation
Issued 8 February 1997 Resolved
Vessel requested and received a Letter of Deviation to enter the Port of Corpus Christi with an inoperable secondary marine radar.
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Construction/Loadline
Issued 10 April 1996 Resolved
OVERBOARD DISCHARGE MONITOR WAS NOT OPERATIONAL AS REQUIRED BY MARPOL ANNEXI APPENDIX 5.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Electrical
Issued 10 April 1996 Resolved
EMERGENCY GENERATOR'S MANUAL HYDRAULIC STARTING PUMP IS INOPERABLE AS REQUIRED BY SOLAS CHAP. II-1 REG. 44 (2).
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Accommodation/Occupational Safety
Issued 13 September 1993 Resolved
Provide proper steps from gangway to vessels main deck.
Condition: Unknown
Due 20 September 1993
Resolved 14 September 1993

Ownership record