SERENITY III

SERENITY III is a 1993 passenger vessel (inspected). The Coast Guard has recorded 57 inspections since 1993, most recently in January 2026, along with 73 deficiencies and 1 casualty investigation in 2024.

Records from 1993 to 2026. Most recent: inspection, 23 January 2026.

Built
1993
Last inspected
23 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDQ7485
391422
Flag
UNITED STATES
367680150
Maury page id
psix-391422

Inspections, by type

…with no type recorded3
Years with a record 30 calendar years (1993–2026)
The 57 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)72.5 ft × 20.0 ft × 9.0 ft
Registered tonnagegross 87 / net 69
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGEORGE H PELAEZ JR · OCEAN SPRINGS, MS, UNITED STATES · built 1993
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPOMPANO BEACH, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 16 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it87 - Simplified, Gross Ton
69 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ7485MMSI 367680150 · active · compulsorily equipped · granted 17 January 2026, expires 17 January 2036
WCB9557MMSI 367384230 · cancelled · voluntarily equipped · granted 11 November 2008, cancelled 19 November 2008 · licensed under a name not among this hull’s recorded names (not shown)
WCO5914MMSI not assigned · expired · voluntarily equipped · granted 2 November 1994, cancelled 8 January 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 57

23 January 2026 COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8295985
16 April 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8113170
12 March 2025 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8093470
5 June 2024 Administrative Inspection · Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7929044
5 June 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7938497
20 February 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7878214
29 March 2023 Administrative Inspection · Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7659992
14 March 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7650186
18 January 2022 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7385454
5 April 2021 Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7168896
19 January 2021 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7126804
11 February 2020 Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6907245
1 April 2019 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6653401
14 February 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6625604
8 March 2018 Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6361614
16 August 2017 Excursion Permit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6242718
12 April 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6122646
21 March 2017 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6108577
20 October 2016 DAPI Audit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6028265
24 May 2016 Excursion Permit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5885567
19 January 2016 DAPI Audit · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5799319
2 February 2011 Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3936102
8 January 2010 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3660716
21 April 2009 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3456677
29 July 2008 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3285018
16 July 2007 COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2997364
11 April 2007 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2906068
28 July 2006 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2733893
28 July 2005 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2442979
8 October 2004 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2197296
26 July 2004 Annual Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2142859
30 July 2003 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1861343
4 September 2002 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1670219
15 August 2002 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1661746
2 September 2001 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 772275
24 August 2001 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1366541
19 September 2000 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1376320
22 August 2000 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1361665
4 August 1999 MARPOL Annex V Examination · COI Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1401054
21 September 1998 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 798916
17 August 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1130864
31 October 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1119475
6 August 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1380955
27 September 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1142323
23 September 1996 Deficiency Check · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 960132
23 August 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1093086
15 August 1996 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1089907
24 August 1995 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 876051
7 December 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 829124
4 November 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1177758
13 October 1994 Re-Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1180344
18 September 1994 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 874470
18 September 1994 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1171375
20 April 1994 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 857867
26 January 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1163039
9 August 1993 Hull Examination · Initial Construction-Excluding Oversight · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1142390
2 August 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1139275

Deficiency record · 73

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 January 2026 Resolved
Each ring life buoy on a vessel must be approved in accordance with 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. MI observed grab lines fitted to the life ring buoys located on the stbd side and near the bridge were deteriorated and must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2026
Resolved 27 February 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 January 2026 Resolved
Retro-reflective material required by this section must be Type I material that is approved under subpart 164.018 of this chapter. MI observed degraded retro-reflective material on 11 life jackets stowed on the bridge. Retro-reflective material on identified life jackets must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2026
Resolved 27 February 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 January 2026 Resolved
Where life preservers are stowed so that they are not readily visible to passengers, the containers in which they are stowed shall be marked "life preservers" and with 'the number contained therein, in at least I-inch letters and figures. Life jacket placards did not accurately reflect the number of life jackets stowed at each location. Update the placard to correct life jacket count.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2026
Resolved 27 February 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 January 2022 Resolved
21 lifejackets need new retroreflective tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2022
Resolved 25 January 2022
Resolution: Vessel replaced all retroreflective tape.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 January 2022 Resolved
Lifebuoy lines are deteriorated. Replace with new
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2022
Resolved 25 January 2022
Resolution: Crew replaced lifebuoy with new one.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 January 2021 Resolved
The engine cooling water system shall be in accordance with the following; Head block and exhaust manifold shall be water jacketed and cooled by water from a pump which operates whenever the engine is operating. Port generator cooling system leak. Replace fitting on heat exchanger. 46CFR182.20-10
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2021
Resolved 26 January 2021
Resolution: Crew replaced fitting on heat exchanger. Test Sat.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 12 April 2017 Resolved
Replace seal for fore peak's hatch. 46CFR179.360
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2017
Resolved 18 April 2017
Resolution: Seal replaced
Engineering › Shafting/Propeller Arrangements › Stern Tube Bearing
Issued 12 April 2017 Resolved
Submit repair proposal. Replace cutless bearing in stern tube. 46CFR176.800
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2017
Resolved 18 April 2017
Resolution: Yacht Management submitted letter attesting to proper operation of the cutlass bearing.
Electrical › Electrical Distribution System (service) › Cable
Issued 12 April 2017 Resolved
Install metal supports on cables/wires in engine room. 46CFR183.340(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 18 April 2017
Resolution: Metal Clamps added
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 12 April 2017 Resolved
Repair damaged propeller, starboard. 46CFR182.200
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2017
Resolved 18 April 2017
Resolution: Propeller resurfaced satisfactorily. Deficiency rectified.
Electrical › Electric Generation Source (service) › Generator
Issued 2 February 2011 Resolved
IAW 46 CFR 183.10-5(f)(2) show proof that the generators are derated 80% of full load rating or derate as required.
Action required: 705 - Other - as specified
Due 1 June 2011
Resolved 22 May 2012
Stability › Watertight Integrity › Weathertight Enclosure
Issued 2 February 2011 Resolved
IAW 46 CFR 182.40-1(a)(1)(i) and (ii) where rigid nonmetallic pipe is penetrating FWD engine room bulkhead ensure that the exceptions in above regulations are met.
Action required: 705 - Other - as specified
Due 31 March 2011
Resolved 6 April 2011
Resolution: Vessel does not meet subdiv
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 2 February 2011 Resolved
Replace port engine flexible boot at inlet into engine from keel cooler piping (currently hose is wasted).
Action required: 705 - Other - as specified
Due 31 March 2011
Resolved 5 April 2011
Resolution: hose was replaced.
Engineering › Bilge Water Management System › Piping
Issued 2 February 2011 Resolved
IAW 46 CFR 182.25-5(d) the bilge pipe piercing the collision BHD shall be fitted with a screw-down valve located forward side of BHD operable from weather deck or a valve without reachrod may be fitted on aft side if readily accessible.
Action required: 705 - Other - as specified
Due 31 March 2011
Resolved 5 April 2011
Resolution: Vessel rep will close valve aft of collision bulkhead and will use a hand portable bilge pump IAW 46 CFR 182.25-5 (a)(1).
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 February 2011 Resolved
Remove dead-end cable sitting on STBD hot water heater in engine room or properly terminate in electrical box.
Action required: 705 - Other - as specified
Due 31 March 2011
Resolved 5 April 2011
Resolution: Dead-end cable was removed.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 February 2011 Resolved
Properly splice light fixture STBD side in lazarette.
Action required: 705 - Other - as specified
Due 31 March 2011
Resolved 5 April 2011
Resolution: Wire was spliced properly.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 2 February 2011 Resolved
IAW 46 CFR 177.405 (f) waste receptacles must be constructed of non-combustible material with no openings in the sides or bottom.
Action required: 705 - Other - as specified
Due 31 March 2011
Resolved 6 April 2011
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 2 February 2011 Resolved
Provide FCC Bridge-to-Bridge certificate onboard.
Action required: 705 - Other - as specified
Due 31 March 2011
Resolved 6 April 2011
Deck/Cargo › Ballast › Special Ballast Arrangements
Issued 2 February 2011 Resolved
Show that cement ballast is IAW stability letter and ballast plan.
Action required: 705 - Other - as specified
Due 2 March 2011
Resolved 3 February 2011
Resolution: Reviewed stability data and found cement ballast was accounted for in SST.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 8 January 2010 Resolved
Provide updated Certificate of Documentation with new owner name and address.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 January 2010
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 8 January 2010 Resolved
Provide drug consortium information IAW CFR.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2010
Operations/Management › Drills/Instruction › Fire
Issued 8 January 2010 Resolved
Conduct fire and man overboard drills to the satisfaction of attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2010
Stability › Weathertight Integrity › General
Issued 8 January 2010 Resolved
Permanently repair cracked fwd bridge window.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2010
Communications › Public Address System › Loudspeaker
Issued 8 January 2010 Resolved
Provide public address system that can be heard in all lower accom spaces.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2010
Stability › Weathertight Integrity › General
Issued 8 January 2010 Resolved
Properly repair worn port side bridge window.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2010
Documentation › Markings/Placards › Lifejacket Placard
Issued 8 January 2010 Resolved
Properly mount life jacket downing placard for passengers to view.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2010
Operations/Management › Drills/Instruction › Fire
Issued 8 January 2010 Resolved
Provide operating instructions for bilge and fire main systems.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2010
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 8 January 2010 Resolved
Properly install lagging on port generator at the manifold.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2010
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 8 January 2010 Resolved
Make permanent repair to wasted piping on the port generator IVO water injection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 January 2010 Resolved
Replace the following expired items in the first aid kit; Iodine swabs, Ammonia inhalants, and Eye irrigation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2010
Operations/Management › Drills/Instruction › Not Conducted
Issued 8 January 2010 Resolved
Conduct steering and propulsion tests to the satisfaction of attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2010
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 8 January 2010 Resolved
Submit repair proposal for review and approval prior to doing any work to holed exhaust piping on port generator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2010
Electrical › Lighting (service) › Lighting Fixture
Issued 8 January 2010 Resolved
Properly install cover on light fixture in laundry room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2010
Construction/Loadline › Structures › Superstructure
Issued 8 January 2010 Resolved
Submit proposal for review and approval to repair two rotted stanchions located on the main deck aft.
Action required: 705 - Other - as specified
Due 26 January 2010
Resolved 20 January 2010
Electrical › Lighting (service) › Lighting Fixture
Issued 21 April 2009 Resolved
Repair or replace light fixture in lazarette.
Action required: 705 - Other - as specified
Resolved 30 April 2009
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 21 April 2009 Resolved
Replace port side shaft cutlass bearings (fwd and aft).
Action required: 705 - Other - as specified
Resolved 30 April 2009
Engineering › Steering Gear System › Rudder Bearing
Issued 21 April 2009 Resolved
Replace port and starboard rudder post bearings.
Action required: 705 - Other - as specified
Resolved 30 April 2009
Stability › Watertight Integrity › General
Issued 21 April 2009 Resolved
Provide nuts and properly secure watertight hatch in lazarette.
Action required: 705 - Other - as specified
Resolved 30 April 2009
Stability › Watertight Integrity › General
Issued 21 April 2009 Resolved
Replace hatch gaskets in forward peak and lazarette.
Action required: 705 - Other - as specified
Resolved 30 April 2009
Communications › Alarms/Indicators › High Water Alarm
Issued 21 April 2009 Resolved
Properly secure wiring for bilge high level alarm in lazarette.
Action required: 705 - Other - as specified
Resolved 30 April 2009
Engineering › Steering Gear System › Hydraulic Hose
Issued 21 April 2009 Resolved
Properly secure hydraulic steering hoses in lazarette.
Action required: 705 - Other - as specified
Resolved 30 April 2009
Navigation › Piloting/Steering › Marine Charts
Issued 28 July 2006 Resolved
Provide current chart for area of operation.
Action required: 705 - Other - as specified
Due 4 August 2006
Resolved 2 August 2006
Resolution: Fax
Engineering › Fuel Oil Service System › Piping
Issued 28 July 2006 Resolved
Remove plastic cocks from fuel strainers and replace with approved fittings.
Action required: 705 - Other - as specified
Due 4 August 2006
Resolved 2 August 2006
Resolution: Fax
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 28 July 2006 Resolved
Provide Aspirin, Ammonia inhalants, and eye irrigation packs/dressings. IAW 46 CFR 160.041
Action required: 705 - Other - as specified
Due 4 August 2006
Resolved 2 August 2006
Resolution: FAX
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 28 July 2005 Resolved
Provide 01 B-II Fire Extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2005
Resolved 12 April 2007
Resolution: onboard
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 28 July 2005 Resolved
Provide proper Ring Life Bouy water light lanyard.
Action required: 705 - Other - as specified
Due 10 August 2005
Resolved 12 April 2007
Resolution: onboard
Electrical › Lighting (service) › Lighting Fixture
Issued 28 July 2005 Resolved
Provide proper light fixture cover in lazerette.
Action required: 705 - Other - as specified
Due 10 August 2005
Resolved 12 April 2007
Resolution: onboard
Operations/Management › Drills/Instruction › Fire
Issued 26 July 2004 Resolved
Conduct additional emergency drills as required by 46 CFR 185.520 and 185.524.
Condition: Placed in Improper Service
Due 31 July 2004
Resolved 25 August 2004
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 30 July 2003 Resolved
Install new generator breaker on the port generator. Breaker must be rated at/to 80% of full rated load.
Condition: Placed in Improper Service
Due 7 August 2003
Resolved 26 July 2004
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 30 July 2003 Resolved
Install new generator breaker on the starboard generator. Breaker must be rated at/to 80% of full rated load.
Condition: Placed in Improper Service
Due 7 August 2003
Resolved 26 July 2004
Electrical › Electric Generation Source (service) › Power Requirement
Issued 30 July 2003 Resolved
Install name plate on port and starboard generators specifying the derated capacity.
Due 7 August 2003
Resolved 25 August 2004
Electrical › Electric Generation Source (service)
Issued 15 August 2002 Resolved
Renew port generator belt driven JABSCO pump, raw water seal.
Due 30 August 2002
Resolved 4 October 2002
Construction/Loadline › Markings
Issued 15 August 2002 Resolved
Provide permanent draft marks. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Due 30 September 2002
Resolved 4 October 2002
Construction/Loadline › Hull
Issued 15 August 2002 Resolved
Crop and renew doubler portside under portside fuel supply valve. LEGACY COMPONENT DESC: Bottom Plating
Due 30 September 2002
Resolved 4 October 2002
Construction/Loadline
Issued 24 August 2001 Resolved
Provide high level alarms for bilge in bow thruster room.
Condition: Unknown
Due 24 August 2001
Resolved 24 August 2001
Construction/Loadline
Issued 24 August 2001 Resolved
Provide latches for all watertight hatches.
Condition: Unknown
Due 24 August 2001
Resolved 24 August 2001
Lifesaving
Issued 24 August 2001 Resolved
Provide speakers inside vessel for public address system.
Condition: Unknown
Due 24 August 2001
Resolved 24 August 2001
Construction/Loadline
Issued 24 August 2001 Resolved
Provide missing draft marks on the side of the vessel.
Condition: Unknown
Due 24 August 2001
Resolved 24 August 2001
Navigation
Issued 24 August 2001 Resolved
Replace missing/broken rod on steering assist hyrdo ram.
Condition: Unknown
Due 24 August 2001
Resolved 24 August 2001
Navigation
Issued 22 August 2000 Resolved
Prior to 22 SEP 00, provide appropriate nautical publications IAW 46CFR185.20-35._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 August 2000
Resolved 28 August 2000
Accommodation/Occupational Safety
Issued 22 August 2000 Resolved
Prior to 22 SEP 00, label compartment of the emergency escape hatch from the FWD berth, PORT side.
Condition: Unknown
Due 28 August 2000
Resolved 28 August 2000
Fire Fighting
Issued 22 August 2000 Resolved
Prior to 22SEP00, provide a B-II portable fire extinguisher for galley IAW 46CFR table 181.30-1(a).
Condition: Unknown
Due 28 August 2000
Resolved 28 August 2000
Documentation
Issued 22 August 2000 Resolved
Prior to 22SEP00, provide information on companies chemical testing program.
Condition: Unknown
Due 22 August 2000
Resolved 22 August 2000
Construction/Loadline
Issued 22 August 2000 Resolved
Prior to 22 SEP 00, provide a stop check valve for each bilge suction line IAW 46CFR182.255.5(c)
Condition: Unknown
Due 28 August 2000
Resolved 28 August 2000
Documentation
Issued 4 August 1999 Resolved
WITHIN SEVEN DAYS PROVIDE ALL REQUIRED DRUG TESTING PAPERWORK AS PER ATTACHED CHECK OFF SHEET.
Condition: Unknown
Due 11 August 1999
Resolved 9 August 1999
Electrical
Issued 6 August 1997 Resolved
Repair emergency lighting in crew spaces below deck.
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Fire Fighting
Issued 23 August 1996 Resolved
REPAIR/REPLACE FIREPUMP TO OBTAIN 60 PSI WITH ONE FIRE STATION OPEN.
Condition: Unknown
Due 23 August 1996
Resolved 23 August 1996
Fire Fighting
Issued 15 August 1996 Resolved
PROVIDE A DISCHARGE GAUGE ON FIREPUMP.
Condition: Unknown
Due 15 September 1996
Resolved 27 August 1996
Construction/Loadline
Issued 15 August 1996 Resolved
PROVE OPERATION OF BILGE SYSTEM BEFORE OPERATION WITH PASSENGERS.
Condition: Unknown
Due 22 August 1996
Resolved 27 August 1996
Electrical
Issued 15 August 1996 Resolved
PROVIDE EMERGENCY LIGHTING FOR CREWS QUARTERS.
Condition: Unknown
Due 15 September 1996
Resolved 27 August 1996
Documentation
Issued 13 October 1994 Resolved
Provide evidence of FCC safety certification for installed radios.
Condition: Unknown
Due 13 October 1994
Resolved 4 November 1994
Documentation
Issued 13 October 1994 Resolved
Provide evidence of a valid drug testing program meeting the requirements in 46 CFR part 16.
Condition: Unknown
Due 13 October 1994
Resolved 13 October 1994
Documentation
Issued 26 January 1994 Resolved
PROVIDE FOR [name withheld] VESSEL PLANS:_x001C_ 1. MACHINERY INSTALLATION_x001C_ 2. ELECTRICAL INSTALLATION_x001C_ 3. FUEL TANKS
Condition: Unknown
Due 26 January 1994
Resolved 26 January 1994

Casualty record · 1

5 June 2024Routine · role: Involved in a Marine Casualty · at SR 844, 14TH STREET, AICW · activity 7938497
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.