Records from 1993 to 1997. Most recent: inspection, 6 August 1997.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Unknown
Issued 6 August 1997
Resolved
Conduct ABS annual survey of all three cranes.
Condition: Unknown
Due 6 September 1997
Resolved 8 September 1997
Unknown
Issued 6 August 1997
Resolved
Replace distorted and/or weakened chain link fence sections around helo deck perimeter netting; secure same to safety wire with corrosion resistantbinding.
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Unknown
Issued 6 August 1997
Resolved
Replace obstruction light lenses (nav-aid lights) or effectively clean paint overspray and/or diesel exhaust soot.
Condition: Unknown
Due 20 August 1997
Resolved 8 September 1997
Unknown
Issued 6 August 1997
Resolved
Replace all three rubber expansion joints on water tower-to-manifold sea water pump connections.
Condition: Unknown
Due 6 September 1997
Resolved 8 September 1997
Unknown
Issued 6 August 1997
Resolved
Complete bench testing of relief valves on all three rig air receivers.
Condition: Unknown
Due 6 September 1997
Resolved 8 September 1997
Unknown
Issued 6 August 1997
No resolution recorded
Repair cable tray starboard side drill floor.
Condition: Unknown
Due 6 October 1997 — due date passed with no resolution recorded
Unknown
Issued 6 August 1997
Resolved
Replace condemned portable Halon fire extinguishers at both locations on helo deck with CO2 fire extinguishers having a total capacity of not less than 18 kg, with one being so equipped as to enable it to reach the engine area of any helicopter using the deck (1979 IMO MODU Code, 9.11.2.3)
Condition: Unknown
Due 20 August 1997
Resolved 8 September 1997
Unknown
Issued 6 August 1997
Resolved
Conduct following tests on all ship's service generators: reverse power relay, engine overspeed trip, low lube oil pressure shutdown; or provide documentation that ABS has recently satisfactorily conducted same.
Condition: Unknown
Due 6 September 1997
Resolved 8 September 1997
Unknown
Issued 6 August 1997
Resolved
Repair relief valve discharge piping on No. 2 mud pump.
Condition: Unknown
Due 6 September 1997
Resolved 8 September 1997
Unknown
Issued 6 August 1997
Resolved
Reroute cable pull for emergency generator fuel shut off valve or otherswise eliminate excessive binding of same.
Condition: Unknown
Due 6 September 1997
Resolved 8 September 1997
Construction/Loadline
Issued 17 October 1996
Resolved
PROVIDE RENEWED MODU CODE SAFETY CERTIFICATE AND COMPLETE OUTSTANDING REPAIRS TO PRELOAD TANKS AS REQUIRED BY ABS. CONTINUANCE OF LETTER OF COMPLIANCE CONTINGENT UPON SATISFACTION OF THIS REQUIREMENT.
Condition: Unknown
Due 17 October 1996
Resolved 17 October 1996
Electrical
Issued 9 August 1996
Resolved
PERFORM TOTAL RIG SHUTDOWN.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Electrical
Issued 9 August 1996
Resolved
REPAIR WASTED CABLE TRAY ON EXTERIOR OF FORWARD BULKHEAD OF SHAKER HOUSE.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Electrical
Issued 9 August 1996
Resolved
REMOUNT GAS SENSOR ABOVE "POSSUM'S BELLY" IN SHAKER HOUSE.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Fire Fighting
Issued 9 August 1996
Resolved
PERFORM IN PRESENCE OF A COAST GUARD MARINE INSPECTOR FIRE AND ABANDONMENT DRILLS.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Electrical
Issued 9 August 1996
Resolved
RECONFIGURE MUDPIT ROOM VENTILATION TO OBTAIN NEGATIVE PRESSURE INSIDE THE ROOM.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Engineering
Issued 9 August 1996
Resolved
PROVIDE FLAME SHIELD BOWLS ON ALL RACOR FUEL FILTERS ON ALL MAIN AND EMERGENCY GENERATORS.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Lifesaving
Issued 9 August 1996
Resolved
REPAIR WINCH BRAKE RELEASE FOR #1 LIFEBOAT.
Condition: Unknown
Due 9 August 1996
Resolved 9 August 1996
Lifesaving
Issued 9 August 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 9 August 1996
Resolved 9 August 1996
Lifesaving
Issued 9 August 1996
Resolved
PROVIDE AN EPIRB OR EXEMPTION LETTER REGARDING EPIRB.
Condition: Unknown
Due 9 August 1996
Resolved 9 August 1996
Fire Fighting
Issued 9 August 1996
Resolved
PREOVIDE FOAM ANALYSIS REPORT ON HELODECK FOAM SYSTEM.
Condition: Unknown
Due 9 August 1996
Resolved 9 August 1996
Navigation
Issued 9 August 1996
Resolved
CORRECT FOGHORN SOUNDING INTERVAL TO COMPLY WITH GULF OF MEXICO REQUIREMENTS.
Condition: Unknown
Due 9 August 1996
Resolved 9 August 1996
Electrical
Issued 9 August 1996
Resolved
REPAIR AND PROVE PROPER OPERATION OF PURGE ALARM TO DRILLER'S CONSOLE AND TO TOP DRIVE CONSOLE ON DRILL FLOOR. MAINTAIN A LIVE WATCH OF PURGE AIR PRESSURE GAUGES UNTIL REPAIRS ARE COMPLETE.
Condition: Unknown
Due 9 August 1996
Resolved 9 August 1996
Construction/Loadline
Issued 9 August 1996
Resolved
ADJUST QUICK ACTING WATERTIGHT DOOR ON 1ST LEVEL OF QUARTERS LEADING OUT TOTHE MAINDECK.
Condition: Unknown
Due 9 August 1996
Resolved 9 August 1996
Electrical
Issued 9 August 1996
Resolved
REPLACE MISSING SWITCH COVERS ON #2 GENERATOR MONITORING PANEL.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Accommodation/Occupational Safety
Issued 9 August 1996
Resolved
REPAIR DOOR LATCHES TO SCR ROOM.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Accommodation/Occupational Safety
Issued 9 August 1996
Resolved
ADJUST ALL AUTOMATIC CLOSING DOORS IN QUARTERS STAIR TOWER.
Condition: Unknown
Due 9 August 1996
Resolved 9 August 1996
Fire Fighting
Issued 9 August 1996
Resolved
REPLACE STEM VALVE ON FIRE STATION #17.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Construction/Loadline
Issued 9 August 1996
Resolved
CORRECT LEAKING PACKING GLANDS ON #2 BILGE PUMP AND ON #1 DRILL WATER PUMP.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Fire Fighting
Issued 9 August 1996
Resolved
COMPLETE REPAIRS TO SCR ROOM HALON SYSTEM.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Lifesaving
Issued 9 August 1995
Resolved
PROVIDE TWO QUICK RELEASE RING BUOYS (ONE ON EACH SIDE OF VESSEL) WITH SMOKE AND LIGHT AND ENSURE PROPERLY MOUNTED ON OUTSIDE OF RAILING. NO LIFELINES SHALL BE ATTACHED TO THE QUICK RELEASE RING BUOYS.
Condition: Unknown
Due 9 August 1995
Resolved 9 August 1995
Electrical
Issued 9 August 1995
Resolved
REPAIR OR REPLACE EXPLOSION PROOF LIGHT AT MUD CHARGING PUMPS ON STBD AFT MAIN DECK.
Condition: Unknown
Due 9 August 1995
Resolved 9 August 1995
Engineering
Issued 9 August 1995
Resolved
REPLACE NON-FUEL SERVICE TYPE HOSE ON DIESEL REFUELING REEL STATION ON TOP DECK AT WIRELINE UNIT WITH FUEL SERVICE TYPE HOSE.
Condition: Unknown
Due 9 August 1995
Resolved 9 August 1995
Lifesaving
Issued 9 August 1995
Resolved
PROVIDE DOCUMENTATION THAT SPIDER BASKETS BEING USED BY PAINTING CONTRACTORS HAVE BEEN SERVICED AND INSPECTED IN ACCORDANCE WITH 29 CFR 1910.66.
Condition: Unknown
Due 9 August 1995
Resolved 9 August 1995
Electrical
Issued 9 August 1995
Resolved
PROVIDE EYS OR BICC FITTINGS ON LIGHT FIXTURES IN MUD PIT ROOM.
Condition: Unknown
Due 9 August 1995
Resolved 9 August 1995
Engineering
Issued 9 August 1995
Resolved
INSTALL FLAME SHIELD BOWLS ON RACOR FUEL FILTERS IN EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 9 August 1995
Resolved 9 August 1995
Deck/Cargo
Issued 9 August 1995
Resolved
MAKE REPAIRS TO CRACK IN WELD AT OUTBOARD TOP OF PORT CRANE PEDESTAL AT GUSSET PLATE. ENSURE ABS IS NOTIFIED OF CRACK AND CRACK IS REPAIRED TO THEIR SATISFACTION.
Condition: Unknown
Due 9 August 1995
Resolved 9 August 1995
Accommodation/Occupational Safety
Issued 3 December 1993
Resolved
REPLACE ALL AIR RECEIVER RELIEF VALVES WITH HAND LIFTING TYPE AND PROVE PROPER OPERATION.
Condition: Unknown
Due 3 December 1993
Resolved 3 December 1993
Documentation
Issued 3 December 1993
Resolved
SUBMIT CERTIFICATE OF REGISTRY TO REFLECT NEW OWNER & NAME TO [name withheld], LA.
Condition: Unknown
Due 3 December 1993
Resolved 3 December 1993
Electrical
Issued 11 August 1993
Resolved
ELECTRIC CABLE UNDER SHELL SHAKER NOT IDENTIFIED OR PROPERLY DEAD ENDED.
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993
Electrical
Issued 11 August 1993
Resolved
ELECTRIC LIGHT FIXTURES ON PORT SIDE MID-LEVEL OUTSIDE OF DRILL FLOOR ARE BROKEN.
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993
Lifesaving
Issued 11 August 1993
Resolved
[name withheld] CANDLEVERBRA AND OUTSIDE OF GALLEY PORTSIDE.
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993
Lifesaving
Issued 11 August 1993
Resolved
DRINKING WATER MISSING FROM BOTH RESCUE CAPSULE (70 BAGS)_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993
Lifesaving
Issued 11 August 1993
Resolved
ALL AIR BOTTLES IN BOTH RESCUE CAPSULES NEED HYDRO TESTED. (12 TOTAL)_x001C_
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993
Lifesaving
Issued 11 August 1993
Resolved
MILK IN BOTH RESCUE CAPSULES NEEDS REPLACED.
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993
Accommodation/Occupational Safety
Issued 11 August 1993
Resolved
ALL AIR RECEIVER RELIEF VALVES NEED REPLACED WHT A TYPE WITH HAND RELIEFINGDEVICES.
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993
Accommodation/Occupational Safety
Issued 11 August 1993
Resolved
GENERAL ALARM BELLS INOP IN STOREROOM AND FIRE PUMP ROOM.
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993
Accommodation/Occupational Safety
Issued 11 August 1993
Resolved
GENERAL ALARM LIGHT IN MUD PUMP ROOM INOP.
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993
Lifesaving
Issued 11 August 1993
Resolved
#A RESCUE CAPSULE REQUIRES WEIGHT TEST.
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993
Fire Fighting
Issued 11 August 1993
Resolved
56 PORTABLE FIRE EXTINGUISHERS REQUIRE HYDRO TESTING. THOSE NOT TESTED SINCE 1988.
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993