GLOMAR ADRIATIC VI is a 1981 mobile offshore drilling unit. The Coast Guard has recorded 10 inspections since 1993, most recently in August 1997, along with 50 deficiencies — 1 with no resolution recorded —.

Records from 1993 to 1997. Most recent: inspection, 6 August 1997.

Built
1981
Last inspected
6 August 1997
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

391798
Flag
PANAMA
—
Maury page id
psix-391798

Inspections, by type

…past their stated due date1
Years with a record 5 calendar years (1993–1997)
The 10 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it4299 - Regulatory (Subpart C or D), Net Ton
1917 - Convention (Subpart B), Net Ton
4299 - Regulatory (Subpart C or D), Gross Ton
6390 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 10

6 August 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1427392
17 October 1996 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439789
9 August 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1380613
9 August 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1440959
11 August 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1385296
8 February 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1163880
10 December 1993 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1162893
8 December 1993 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 849487
3 December 1993 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1157961
11 August 1993 Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 845626

Deficiency record · 50

Unknown
Issued 6 August 1997 Resolved
Conduct ABS annual survey of all three cranes.
Condition: Unknown
Due 6 September 1997
Resolved 8 September 1997
Unknown
Issued 6 August 1997 Resolved
Replace distorted and/or weakened chain link fence sections around helo deck perimeter netting; secure same to safety wire with corrosion resistantbinding.
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Unknown
Issued 6 August 1997 Resolved
Replace obstruction light lenses (nav-aid lights) or effectively clean paint overspray and/or diesel exhaust soot.
Condition: Unknown
Due 20 August 1997
Resolved 8 September 1997
Unknown
Issued 6 August 1997 Resolved
Replace all three rubber expansion joints on water tower-to-manifold sea water pump connections.
Condition: Unknown
Due 6 September 1997
Resolved 8 September 1997
Unknown
Issued 6 August 1997 Resolved
Complete bench testing of relief valves on all three rig air receivers.
Condition: Unknown
Due 6 September 1997
Resolved 8 September 1997
Unknown
Issued 6 August 1997 No resolution recorded
Repair cable tray starboard side drill floor.
Condition: Unknown
Due 6 October 1997 — due date passed with no resolution recorded
Unknown
Issued 6 August 1997 Resolved
Replace condemned portable Halon fire extinguishers at both locations on helo deck with CO2 fire extinguishers having a total capacity of not less than 18 kg, with one being so equipped as to enable it to reach the engine area of any helicopter using the deck (1979 IMO MODU Code, 9.11.2.3)
Condition: Unknown
Due 20 August 1997
Resolved 8 September 1997
Unknown
Issued 6 August 1997 Resolved
Conduct following tests on all ship's service generators: reverse power relay, engine overspeed trip, low lube oil pressure shutdown; or provide documentation that ABS has recently satisfactorily conducted same.
Condition: Unknown
Due 6 September 1997
Resolved 8 September 1997
Unknown
Issued 6 August 1997 Resolved
Repair relief valve discharge piping on No. 2 mud pump.
Condition: Unknown
Due 6 September 1997
Resolved 8 September 1997
Unknown
Issued 6 August 1997 Resolved
Reroute cable pull for emergency generator fuel shut off valve or otherswise eliminate excessive binding of same.
Condition: Unknown
Due 6 September 1997
Resolved 8 September 1997
Construction/Loadline
Issued 17 October 1996 Resolved
PROVIDE RENEWED MODU CODE SAFETY CERTIFICATE AND COMPLETE OUTSTANDING REPAIRS TO PRELOAD TANKS AS REQUIRED BY ABS. CONTINUANCE OF LETTER OF COMPLIANCE CONTINGENT UPON SATISFACTION OF THIS REQUIREMENT.
Condition: Unknown
Due 17 October 1996
Resolved 17 October 1996
Electrical
Issued 9 August 1996 Resolved
PERFORM TOTAL RIG SHUTDOWN.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Electrical
Issued 9 August 1996 Resolved
REPAIR WASTED CABLE TRAY ON EXTERIOR OF FORWARD BULKHEAD OF SHAKER HOUSE.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Electrical
Issued 9 August 1996 Resolved
REMOUNT GAS SENSOR ABOVE "POSSUM'S BELLY" IN SHAKER HOUSE.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Fire Fighting
Issued 9 August 1996 Resolved
PERFORM IN PRESENCE OF A COAST GUARD MARINE INSPECTOR FIRE AND ABANDONMENT DRILLS.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Electrical
Issued 9 August 1996 Resolved
RECONFIGURE MUDPIT ROOM VENTILATION TO OBTAIN NEGATIVE PRESSURE INSIDE THE ROOM.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Engineering
Issued 9 August 1996 Resolved
PROVIDE FLAME SHIELD BOWLS ON ALL RACOR FUEL FILTERS ON ALL MAIN AND EMERGENCY GENERATORS.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Lifesaving
Issued 9 August 1996 Resolved
REPAIR WINCH BRAKE RELEASE FOR #1 LIFEBOAT.
Condition: Unknown
Due 9 August 1996
Resolved 9 August 1996
Lifesaving
Issued 9 August 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 9 August 1996
Resolved 9 August 1996
Lifesaving
Issued 9 August 1996 Resolved
PROVIDE AN EPIRB OR EXEMPTION LETTER REGARDING EPIRB.
Condition: Unknown
Due 9 August 1996
Resolved 9 August 1996
Fire Fighting
Issued 9 August 1996 Resolved
PREOVIDE FOAM ANALYSIS REPORT ON HELODECK FOAM SYSTEM.
Condition: Unknown
Due 9 August 1996
Resolved 9 August 1996
Navigation
Issued 9 August 1996 Resolved
CORRECT FOGHORN SOUNDING INTERVAL TO COMPLY WITH GULF OF MEXICO REQUIREMENTS.
Condition: Unknown
Due 9 August 1996
Resolved 9 August 1996
Electrical
Issued 9 August 1996 Resolved
REPAIR AND PROVE PROPER OPERATION OF PURGE ALARM TO DRILLER'S CONSOLE AND TO TOP DRIVE CONSOLE ON DRILL FLOOR. MAINTAIN A LIVE WATCH OF PURGE AIR PRESSURE GAUGES UNTIL REPAIRS ARE COMPLETE.
Condition: Unknown
Due 9 August 1996
Resolved 9 August 1996
Construction/Loadline
Issued 9 August 1996 Resolved
ADJUST QUICK ACTING WATERTIGHT DOOR ON 1ST LEVEL OF QUARTERS LEADING OUT TOTHE MAINDECK.
Condition: Unknown
Due 9 August 1996
Resolved 9 August 1996
Electrical
Issued 9 August 1996 Resolved
REPLACE MISSING SWITCH COVERS ON #2 GENERATOR MONITORING PANEL.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Accommodation/Occupational Safety
Issued 9 August 1996 Resolved
REPAIR DOOR LATCHES TO SCR ROOM.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Accommodation/Occupational Safety
Issued 9 August 1996 Resolved
ADJUST ALL AUTOMATIC CLOSING DOORS IN QUARTERS STAIR TOWER.
Condition: Unknown
Due 9 August 1996
Resolved 9 August 1996
Fire Fighting
Issued 9 August 1996 Resolved
REPLACE STEM VALVE ON FIRE STATION #17.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Construction/Loadline
Issued 9 August 1996 Resolved
CORRECT LEAKING PACKING GLANDS ON #2 BILGE PUMP AND ON #1 DRILL WATER PUMP.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Fire Fighting
Issued 9 August 1996 Resolved
COMPLETE REPAIRS TO SCR ROOM HALON SYSTEM.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Lifesaving
Issued 9 August 1995 Resolved
PROVIDE TWO QUICK RELEASE RING BUOYS (ONE ON EACH SIDE OF VESSEL) WITH SMOKE AND LIGHT AND ENSURE PROPERLY MOUNTED ON OUTSIDE OF RAILING. NO LIFELINES SHALL BE ATTACHED TO THE QUICK RELEASE RING BUOYS.
Condition: Unknown
Due 9 August 1995
Resolved 9 August 1995
Electrical
Issued 9 August 1995 Resolved
REPAIR OR REPLACE EXPLOSION PROOF LIGHT AT MUD CHARGING PUMPS ON STBD AFT MAIN DECK.
Condition: Unknown
Due 9 August 1995
Resolved 9 August 1995
Engineering
Issued 9 August 1995 Resolved
REPLACE NON-FUEL SERVICE TYPE HOSE ON DIESEL REFUELING REEL STATION ON TOP DECK AT WIRELINE UNIT WITH FUEL SERVICE TYPE HOSE.
Condition: Unknown
Due 9 August 1995
Resolved 9 August 1995
Lifesaving
Issued 9 August 1995 Resolved
PROVIDE DOCUMENTATION THAT SPIDER BASKETS BEING USED BY PAINTING CONTRACTORS HAVE BEEN SERVICED AND INSPECTED IN ACCORDANCE WITH 29 CFR 1910.66.
Condition: Unknown
Due 9 August 1995
Resolved 9 August 1995
Electrical
Issued 9 August 1995 Resolved
PROVIDE EYS OR BICC FITTINGS ON LIGHT FIXTURES IN MUD PIT ROOM.
Condition: Unknown
Due 9 August 1995
Resolved 9 August 1995
Engineering
Issued 9 August 1995 Resolved
INSTALL FLAME SHIELD BOWLS ON RACOR FUEL FILTERS IN EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 9 August 1995
Resolved 9 August 1995
Deck/Cargo
Issued 9 August 1995 Resolved
MAKE REPAIRS TO CRACK IN WELD AT OUTBOARD TOP OF PORT CRANE PEDESTAL AT GUSSET PLATE. ENSURE ABS IS NOTIFIED OF CRACK AND CRACK IS REPAIRED TO THEIR SATISFACTION.
Condition: Unknown
Due 9 August 1995
Resolved 9 August 1995
Accommodation/Occupational Safety
Issued 3 December 1993 Resolved
REPLACE ALL AIR RECEIVER RELIEF VALVES WITH HAND LIFTING TYPE AND PROVE PROPER OPERATION.
Condition: Unknown
Due 3 December 1993
Resolved 3 December 1993
Documentation
Issued 3 December 1993 Resolved
SUBMIT CERTIFICATE OF REGISTRY TO REFLECT NEW OWNER & NAME TO [name withheld], LA.
Condition: Unknown
Due 3 December 1993
Resolved 3 December 1993
Electrical
Issued 11 August 1993 Resolved
ELECTRIC CABLE UNDER SHELL SHAKER NOT IDENTIFIED OR PROPERLY DEAD ENDED.
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993
Electrical
Issued 11 August 1993 Resolved
ELECTRIC LIGHT FIXTURES ON PORT SIDE MID-LEVEL OUTSIDE OF DRILL FLOOR ARE BROKEN.
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993
Lifesaving
Issued 11 August 1993 Resolved
[name withheld] CANDLEVERBRA AND OUTSIDE OF GALLEY PORTSIDE.
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993
Lifesaving
Issued 11 August 1993 Resolved
DRINKING WATER MISSING FROM BOTH RESCUE CAPSULE (70 BAGS)_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993
Lifesaving
Issued 11 August 1993 Resolved
ALL AIR BOTTLES IN BOTH RESCUE CAPSULES NEED HYDRO TESTED. (12 TOTAL)_x001C_
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993
Lifesaving
Issued 11 August 1993 Resolved
MILK IN BOTH RESCUE CAPSULES NEEDS REPLACED.
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993
Accommodation/Occupational Safety
Issued 11 August 1993 Resolved
ALL AIR RECEIVER RELIEF VALVES NEED REPLACED WHT A TYPE WITH HAND RELIEFINGDEVICES.
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993
Accommodation/Occupational Safety
Issued 11 August 1993 Resolved
GENERAL ALARM BELLS INOP IN STOREROOM AND FIRE PUMP ROOM.
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993
Accommodation/Occupational Safety
Issued 11 August 1993 Resolved
GENERAL ALARM LIGHT IN MUD PUMP ROOM INOP.
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993
Lifesaving
Issued 11 August 1993 Resolved
#A RESCUE CAPSULE REQUIRES WEIGHT TEST.
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993
Fire Fighting
Issued 11 August 1993 Resolved
56 PORTABLE FIRE EXTINGUISHERS REQUIRE HYDRO TESTING. THOSE NOT TESTED SINCE 1988.
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.