Records from 1993 to 2005. Most recent: inspection, 18 August 2005.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 12
18 August 2005
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2466729
16 March 2005
COC-MODU Renew · Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2311360
24 June 1997
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1112531
19 August 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1371510
16 February 1996
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 883340
26 January 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 154004
8 December 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1187964
14 August 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1425627
26 October 1994
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1174681
3 August 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1425494
1 August 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 868551
4 August 1993
Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1415865
Electrical › Lighting (service) › Lighting Fixture
Issued 21 March 2005
Resolved
Repair or replace all broken explosion proof lights in hazardous areas prior to drilling operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 April 2005
Resolved 24 March 2005
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 16 March 2005
Resolved
Submit Emergency Evacuation Plan for approval IAW 33CFR146.140 prior to drilling operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 April 2005
Resolved 12 August 2005
Resolution: Reviewed and approved EEP.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 16 March 2005
Resolved
Replace inoperable bracket for fire extinguisher #39.
Action required: 705 - Other - as specified
Due 16 April 2005
Resolved 17 March 2005
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 16 March 2005
Resolved
Remove or repair 2 urinals in public toilet 2nd level.
Action required: 705 - Other - as specified
Due 16 April 2005
Resolved 17 March 2005
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 16 March 2005
Resolved
Repair broken door knob room #122.
Action required: 705 - Other - as specified
Due 16 April 2005
Resolved 17 April 2005
Engineering › Generator (propulsion-electric) › Wiring
Issued 16 March 2005
Resolved
Repair #3 Generator low lube oil shutdown.
Action required: 705 - Other - as specified
Due 16 April 2005
Resolved 17 March 2005
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 16 March 2005
Resolved
Replace worn hydraulic hose on lifeboat and secure/protect new hose.
Action required: 705 - Other - as specified
Due 16 April 2005
Resolved 17 March 2005
Lifesaving › Lifeboat › Propulsion Engine
Issued 16 March 2005
Resolved
Prove proper operation of port lifeboat engine.
Action required: 705 - Other - as specified
Due 16 April 2005
Resolved 17 March 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 16 March 2005
Resolved
Demonstrate purge alarms on driller's console prior to drilling operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 April 2005
Resolved 24 March 2005
Fire Fighting › Remote Fuel Shutoff › General
Issued 16 March 2005
Resolved
Replace broken glass on emergency shutdowns behind driller's shack.
Action required: 705 - Other - as specified
Due 16 April 2005
Resolved 17 March 2005
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 16 March 2005
Resolved
Replace missing hammer for "break glass" alarm box in generator room.
Action required: 705 - Other - as specified
Due 16 April 2005
Resolved 17 March 2005
Electrical
Issued 19 August 1996
Resolved
Replace all discharged emergency lighting batteries and/or faulty relays throughout rig.
Condition: Unknown
Due 19 September 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 19 August 1996
Resolved
Research and provide written test procedures for verifying proper operationof Oily Water Separator (OWS) 15 ppm monitor and alarm/solenoid valve activation.
Condition: Unknown
Due 19 September 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 19 August 1996
Resolved
Review Operations Manual; purge redundant information/copies, insert current revisions regarding stability calculations, etc., in appropriate chapters.
Condition: Unknown
Due 19 September 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 19 August 1996
Resolved
Conduct weight tests of port and starboard lifeboats and respective davits due to renewal of lifeboat davit falls (cables) on 7th and 12th of July, 1996.
Condition: Unknown
Due 19 September 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 19 August 1996
Resolved
Test emergency fire pump and associated deep well pump simultaneously whilerig is under load of emergency generator only (to be done when operations permit, but no later than September 19, 1996.
Condition: Unknown
Due 19 September 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 14 August 1995
Resolved
PROVE PROPER OPS OF GENERAL ALARM BELL UNDER SHAKER AREA.
Condition: Unknown
Due 14 August 1995
Resolved 14 August 1995
Electrical
Issued 14 August 1995
Resolved
INSTALL EMERGENCY LIGHT IN QUARTERS 2ND DECK STBDSIDE.
Condition: Unknown
Due 14 August 1995
Resolved 14 August 1995
Lifesaving
Issued 14 August 1995
Resolved
PROVE PROPER OPS OF RIG'S CATEGORY I EPIRB & LIFE CAPSULE #2 CLASS B EPIRB.
Condition: Unknown
Due 14 August 1995
Resolved 14 August 1995
Fire Fighting
Issued 14 August 1995
Resolved
DESIGN & INSTALL SUPPORT PLATFORM FOR HALON BOTTLE TO RADIO ROOM TO BE OFF THE MAINDECK.
Condition: Unknown
Due 14 August 1995
Resolved 14 August 1995
Fire Fighting
Issued 14 August 1995
Resolved
DESIGN & INSTALL SUPPORT PLATFORM FOR HALON BOTTLE TO EMERGENCY GENERATOR SPACE TO BE OFF THE MAINDECK.
Condition: Unknown
Due 14 August 1995
Resolved 14 August 1995
Navigation
Issued 14 August 1995
Resolved
CORRECT TIMING INTERVAL ON FOGHORN & OBSTRUCTION LIGHTS IN ACCORDANCE WITH 33CFR67.
Condition: Unknown
Due 14 August 1995
Resolved 14 August 1995
Fire Fighting
Issued 14 August 1995
Resolved
ITEMS #1 & 2 REROUTE FLEXIBLE DISCHARGE LINES OR REDESIGN FLEXIBLE DISCHARGE LINES.
Condition: Unknown
Due 14 August 1995
Resolved 14 August 1995
Fire Fighting
Issued 3 August 1994
Resolved
MAKE ALL FIRE HOSES OF THE SAME TYPE (FOREIGN COUPLINGS MIXED WITH U.S. COUPLINGS).
Condition: Unknown
Due 3 August 1994
Resolved 3 August 1994
Accommodation/Occupational Safety
Issued 3 August 1994
Resolved
MAKE REPAIRS TO VENT DUCTING IN MUDPIT ROOM AND SEAL PIPE PENETRATION AT PORT AFT BULKHEAD (REPAIRS IN PROGRESS).
Condition: Unknown
Due 3 August 1994
Resolved 3 August 1994
Electrical
Issued 3 August 1994
Resolved
PROPERLY POUR SEALING COMPOUND IN EYS FITTINGS ON DRILL FLOOR AFT BULKHEAD (NEW FITTINGS).
Condition: Unknown
Due 3 August 1994
Resolved 3 August 1994
Fire Fighting
Issued 3 August 1994
Resolved
REPLACE HALON ACTUATING STATION BOXES DUE TO CORROSION.
Condition: Unknown
Due 3 August 1994
Resolved 3 August 1994
Lifesaving
Issued 3 August 1994
Resolved
MAKE REPAIRS TO CRACKED TOP SHELL OF #1 AND #2 LIFEBOATS AT SECURING PADS.
Condition: Unknown
Due 3 August 1994
Resolved 3 August 1994
Lifesaving
Issued 3 August 1994
Resolved
REPAIR BROKEN LIFELINE ON #2 LIFEBOAT AND INTERIOR LIGHT ON #1 LIFEBOAT.
Condition: Unknown
Due 3 August 1994
Resolved 3 August 1994
Lifesaving
Issued 3 August 1994
Resolved
PROPERLY TENSION HYDROSTATIC RELEASES ON ALL LIFERAFTS ANDDD HAVE ANNUAL TEST CONDUCTED ON HYDROSTATIC RELEASE ON LIFERAFT #5.
Condition: Unknown
Due 3 August 1994
Resolved 3 August 1994