Records from 2007 to 2025. Most recent: inspection, 9 December 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 December 2025
Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by table 176.810 (b), in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required serving to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections maintenance procedure, and hydrostatic pressure tests. Owner/operator advised that fixed fire suppression system has not been serviced. Provide service report within seven days.
Action required: 705 - Other - as specified
Due 16 December 2025
Resolved 12 December 2025
Resolution: Within seven days
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 December 2025
Resolved
Battery must be mounted in trays. Battery for engine was removed for replacement. Replace with full serviced battery within seven days. 46CFR183.350(e)
Action required: 705 - Other - as specified
Due 9 December 2025
Resolved 14 December 2025
Resolution: Def recified. Photos provided.
09 - Working and Living Conditions › 092 - Working Conditions › Gas instruments
Issued 24 September 2025
Resolved
"The use and storage of CNG containers within the accommodation area, machinery spaces, bilges, or other enclosed spaces is prohibited." Propane tank found in Void 3. Remove tank.
46 CFR 121.240(c)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 September 2025
Resolution: Removed
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 September 2025
Resolved
"All griddles, broilers, and deep fat fryers must be fitted with a grease extraction hood..." Deep fat fryers found in galley without hood. Remove fryes.
46 CFR 118.400(e)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 September 2025
Resolution: Removed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 September 2025
Resolved
"An electric submersible bilge pump may be used... provided that a positive shutoff valve is installed at the hull penetration." 05 pumps missing seacocks. Install seacocks.
46 CFR 182.520(e)(7)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 20 October 2025
Resolution: 05 Inline Ball Valves installed. Verified installation through photographs.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 September 2025
Resolved
"A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural examination at least once every two years." Vessel exceeded 5 year dry dock requirement. Prior to carriage of passengers, vessel must receive credit drydock.
46 CFR 176.600(c)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2025
Resolution: Cleared last remaining worklist item and issued credit drydock.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 November 2024
Resolved
Except as otherwise provided in this section, all fixed fire extinguishing systems shall be... installed to the satisfaction of the Officer in Charge, Marine Inspection. Despite recent servixe to system, MI conducted an unsuccessful test of the port side fixed firefighting system. Ensure an MI witnesses a successful test.
46 CFR 181.20-5a "OLD T"
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2024
Resolution: Witnessed satisfactory testing of FM200.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 November 2023
Resolved
Cylinders in the Pre-engineered fixed gas fire extinguishing system are not serviced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 November 2023
Resolved 17 November 2023
Resolution: Vessel submitted servicing report for fire supression system.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 15 August 2023
Resolved
A hatch exposed to the weather must be watertight. Fore peak hatch was not watertight. Rectify deficiency prior to receiving credit for dry dock. 46 CFR 179.360(a)
Action required: 705 - Other - as specified
Resolved 16 August 2023
Resolution: Vessel provided photographic evidence of new gasket and clean knife edge.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 November 2022
Resolved
A Pre-engineered fixed gas fire extinguishing system aboard a vessel must be installed in accordance with the manufacturers instructions and meet all requirements from 46 CFR 181.420. System was not installed with proper electrical connections and no connections for the engine and ventilation shut downs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 November 2022
Resolved 22 November 2022
Resolution: Attended vessel and verified def correction.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 November 2022
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in a space with a through hull fitting below the waterline. Visual indicator for the lazarette inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2022
Resolved 22 November 2022
Resolution: Attended vessel and verified def correction.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 November 2022
Resolved
The installation and location of portable fire extinguishers must be to the satisfaction of the [name withheld] portable fire extinguishers were not in their proper bracket required by the extinguishers Sub-chapter Q Specification.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2022
Resolved 22 November 2022
Resolution: Attended vessel and verified def correction.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 November 2022
Resolved
Fire hose nozzle must be bronze or another material that has strength and corrosion resistance properties equal to those of bronze. Fire hose nozzles were plastic.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2022
Resolved 22 November 2022
Resolution: Attended vessel and verified def correction.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 July 2022
Resolved
Repair fire main and prove proper operation as discussed with attending MI.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2022
Resolved 9 July 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 July 2022
Resolved
Renew fire hose in main salon.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2022
Resolved 9 July 2022
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 July 2022
Resolved
Properly mount bilge alarm float switches in all spaces.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2022
Resolved 7 September 2022
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 July 2022
Resolved
Post proper CO2 signage.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2022
Resolved 7 September 2022
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 July 2022
Resolved
Remove AED signage or provide AED.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2022
Resolved 7 September 2022
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 8 July 2022
Resolved
Provide current FCC Station and Safety radio certificates prior to operating beyond 1000 feet from shore.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 August 2022
Resolved 7 September 2022
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 8 July 2022
Resolved
Prove proper operation of VHF radio prior to operating beyond 1000 feet from shore.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2022
Resolved 7 September 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 July 2022
Resolved
Remove stored paint from space forward of the engine room.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2022
Resolved 9 July 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 August 2021
Resolved
The condition of the vessel and its equipment must be acceptable to the cognizant [name withheld] notification and complete new to zone inspection to the satisfaction of local OCMI zone. Including the outstanding CG835's which are not completed. Prior to carriage of passengers or cargo.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2021
Resolved 26 October 2021
Resolution: NTZ inspection completed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 20 July 2021
Resolved
Replace cracked window on portside forward deck and on stern at aft deck.
Turned worklist item into an CG835 to be corrected at new zone at O/O request. Extended 30 days 23SEP21.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2021
Resolved 26 October 2021
Resolution: Windows have been replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 June 2021
Resolved
Vessel required to be equipped with visual distress signals. Existing visual distress signals (day/red) were expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2021
Resolved 14 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 June 2021
Resolved
Vessel required to be equipped with serviceable ring life buoys. Existing ring life buoys require replacement due to deterioration of peripheral grab line.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2021
Resolved 26 October 2021
Resolution: Vessel has replaced all of the ring life buoys on board.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 June 2021
Resolved
Vessel required to be fitted with navigational lights appropriate for its size. Vessel is not fitted with a navigational anchor light.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2021
Resolved 26 October 2021
Resolution: Nav lights are sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 June 2021
Resolved
Vessel required to be equipped with portable fire extinguishers. Existing portable fire extinguishers require annual servicing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 October 2021
Resolution: Fire extinguishers have been serviced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 December 2020
Resolved
A vessel that is exposed to salt water not more than three months in any twelve month period since the last examination must undergo a drydock examination and an internal structural examination at least once ever five years. The vessel's hull & internal structural examination was due on 21NOV2020.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 October 2021
Resolution: Vessel had a drydock and is good until 2023.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 June 2020
Resolved
A vessel that has a power driven fire pump must have a sufficient number of fire hydrants to reach any part of the vessel using a single length of hose. Vessels fire hydrant piping IWO upper deck, starboard side (above stairs) was found wasted/corroded/detached.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2021
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 4 June 2020
Resolved
Vessel required to be carry on board a Certificate of Documentation with a minimum of a Coastwise Endorsement. O/O filed for vessels COD, however, the NVDC is showing the status as "in process".
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 June 2020
Resolved
Any crewmember involved in safety sensitive functions on board the vessel shall be enrolled in a recognized chemical testing program (consortium). O/O failed to provide proof of enrollment in a recognized consortium/program for vessels crew.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2021
Resolved 14 July 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 June 2020
Resolved
Vessel fixed bilge system piping shall be equipped with a suitable strainer. Existing strainers IWO galley void and lazarette were found damaged/missing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 26 October 2021
Resolution: Bilge pump strainers were replaced.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 4 June 2020
Resolved
Installed VHF-FM radio-telephone(s) are required to be programmed with assigned MMSI identification. Existing VHF-FM radio-telephones are not programmed with MMSI identification numbers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2020
Resolved 2 June 2021
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 4 June 2020
Resolved
VHF-FM radio-telephones are required to be interfaced with GPS or be GPS enabled to support DSC requirements. Existing VHF-FM radio-telephones are not interfaced with GPS.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2020
Resolved 14 July 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 June 2020
Resolved
Vessels main diesel engines exhaust systems/piping are required to be water cooled. Existing flow switch for port main diesel engine was inoperable at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2020
Resolved 2 June 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 June 2020
Resolved
Vessel required to be fitted with a first aid kit. Existing first aid kit contents were expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2020
Resolved 2 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 June 2020
Resolved
Vessels ring life buoy is required to be fitted with a rescue line. Exisiting rescue line was found to be improper type/length/size.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2020
Resolved 2 June 2021
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 4 June 2020
Resolved
Vessel required to be fitted with an compass. Existing compass installation is not illuminated.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2020
Resolved 2 June 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 June 2020
Resolved
Vessels panelboards/electrical equipment shall be equipped with face/cover plates to prevent electrical shock. Existing transformer(s) IWO starboard console were missing face/cover plates (wiring/conductors exposed).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2020
Resolved 26 October 2021
Resolution: Cover plates installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 June 2020
Resolved
Conductors that utilize twist on connectors must be made within an enclosure and be secured to prevent loosening. Existing twist on connectors IWO transformers (under starboard console) were not properly secured to prevent loosening.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2020
Resolved 2 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 June 2020
Resolved
All through hull fittings and shutoff valves shall be metallic. Existing through hull/shutoff valve for a/c cooling water was not frozen in the open position.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2020
Resolved 14 July 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 June 2020
Resolved
Vessel has non-watertight hatches installed along the main deck. The non-watertight hatch hinges for void #4 were found fractured/damaged.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2020
Resolved 2 June 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 June 2020
Resolved
Vessels panelboards/electrical equipment shall be equipped with face/cover plates to prevent electrical shock. Existing panelboard IWO engine room (Panel A) missing face/cover plate hardware.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2020
Resolved 26 October 2021
Resolution: Cover plates installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 June 2020
Resolved
All engines shall be water cooled. Existing flexible cooling hose IWO port generator was found kinked/twisted.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2020
Resolved 2 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 June 2020
Resolved
Batteries must be accesible for maintenance and removal. Existing battery installations in way of engine room were found with corroded terminals (lack of maintenance).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2020
Resolved 2 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 February 2019
Resolved
Vessels shore power cable neutral is required to be grounded IAW 46 CFR 183.376. Vessels shore power cable neutral is grounded at the shore/vessel side simultaneously.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 4 June 2020
Resolution: Attending Inspector(s) verified grounding of shore power cable (vessel side only). Vessel does not currently employ a shore power cable (at its Bucksport location).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 February 2019
Resolved
Vessels SSDG is required to be protected by an overcurrent device set at a value not exceeding 115% of SSDG full load rating. Vessel's SSDG breakers ratings exceed 115% of full load rating. Requires on site verification.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 27 February 2019
Resolution: Attending Inspector(s) verified installation of properly size overcurrent protection (225A).
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 February 2019
Resolved
Each vessel required to have a COI is subject to annual vessel inspection fee as per Table 2.10-101 (46 CFR). Owner/Operator is required to establish a users fees account once COI has been issued.
Action required: 705 - Other - as specified
Resolved 1 November 2019
Resolution: Attending Inspector(s) verified establishment of users fee account.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 November 2018
Resolved
Vessel required to be equipped with a fire detection system IAW 46 CFR 181.400(c). Attending Inspector(s) noted that the vessel is not equipped with a fire detection system.
Action required: 705 - Other - as specified
Due 21 November 2020
Resolved 26 October 2021
Resolution: Installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 November 2018
Resolved
Vessel required to be equipped with a fixed fire extinguishing system IAW 46 CFR 181.400(b)(2) & 46 CFR 181.420. Attending Inspector(s) noted that the vessel is not equipped with a fixed fire extinguishing system.
Action required: 705 - Other - as specified
Due 21 November 2020
Resolved 26 October 2021
Resolution: A 02 bottle fireboy system pre-engineered system has been installed.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 2 November 2018
Resolved
Vessel required to be equipped with an operational Class A AIS as per 33 CFR 164.46(b)(1). Attending Inspector(s) noted that vessel is not equipped with an operable Class A AIS unit.
Action required: 705 - Other - as specified
Due 21 November 2020
Resolved 2 August 2021
Resolution: Received notification from USCG NAVEN advising that the AIS unit is operating properly.