← All vessels
PANAMAX GIANT
PANAMAX GIANT is a 1993 freight ship. The Coast Guard has recorded 30 inspections since 1994, most recently in January 2010, along with 20 deficiencies and 6 operational controls.
Records from 1994 to 2010. Most recent: operational control imposed, 7 January 2010.
- Built
- 1993
- Last inspected
- 7 January 2010
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 20 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9045912 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
5BZS2
391916
Flag
PANAMA
—
Maury page id
psix-391916
Inspections, by type
…with no type recorded18
Years with a record
16 calendar years (1994–2010)
The 30 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it71731 - Dead Weight, Ton
81726 - Displacement, Ton
24124 - Convention (Subpart B), Net Ton
38105 - Convention (Subpart B), Gross Ton
81726 - Displacement, Ton
24124 - Convention (Subpart B), Net Ton
38105 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 30
7 January 2010
PI Safety Exam · MARPOL Annex I Examination · Ballast Water Examination · ISPS III Exam · MARPOL Annex VI Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3640068
5 January 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3659285
5 January 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3846781
4 December 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3644730
4 December 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3647708
15 September 2008
Ballast Water Examination · ISPS I Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3319216
13 September 2008
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3324281
21 February 2008
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3151168
1 November 2007
MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3086226
30 October 2007
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3090239
23 October 2007
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3085565
22 August 2006
Ballast Water Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2755132
9 February 2005
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2289576
11 November 2004
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2239553
3 November 2004
PII Safety Exam · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2233912
6 August 2004
ISPS II Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2157962
20 November 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1951646
19 November 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1952473
14 May 2002
Re-Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1616440
14 July 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 291933
12 January 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 285779
3 May 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 277408
27 December 1999
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 436130
12 April 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 427485
22 October 1998
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 421530
11 April 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 414563
17 December 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 398643
28 December 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 385875
12 April 1994
Type not recorded
No type recorded · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 366214
12 April 1994
Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1370822
Deficiency record · 20
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 7 January 2010
Resolved
1430 - Auxiliary Engines - The PSCO found an exhaust leak on the bellows for the No. 3 auxiliary engine leaking excessive with a cement type patch, which is still ineffective in stopping excessive exhaust gases from leaking causing an unsafe condition in the engine room while in operation. SOLAS 74A II-1/26
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 7 January 2010
Resolved
0715 - Detection - The PSCO found 4 out of 9 smoke detectors on the 3rd deack of the engine room for the section covering the auxiliary engines covered in plastic bags effectively isolating them from proper operation. The apparent cause was an excessive exhaust leak from No. 3 auxiliary engine. While in operation and with the bags removed it immediately caused an alarm on those detectors. The C
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 7 January 2010
Resolved
2515 - Based on the above it is the opinion of the PSCO that there is objective evidence that the Company is not ensuring adequate resources and shore based support is being provided to the vessel. It is requested that an external audit be conducted on the Company. ISM Code 3.3
Deck/Cargo › Ballast › Piping
Issued 7 January 2010
Resolved
0999 - Other (safety in general) - The water ballast discharge pipe forward of the No. 2 water ballast pump has a temporary patch.
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (air start)
Issued 7 January 2010
Resolved
1410 - Propulsion main engine - While transiting the Mississippi river your vessel experienced a power lose of the Main Diesel Engine on 04 DEC 2009 and 05 JAN 2010.
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (air start)
Issued 4 December 2009
Resolved
Vessel failed to start in the astern direction from the Engine Control Room.
Engineering › Fuel Oil Service System › Piping
Issued 15 September 2008
Resolved
FUEL OIL SUPPLY PIPING TO DIESEL BURNER ASSEMBLY ON INCINERATOR HAS SEVERAL LEAKS WITH COLLECTION BUCKETS. THIS POSES A FIRE HAZARD. 17c SOLAS 2004 II-2 REG 4.
Deck/Cargo › Ballast › Piping
Issued 3 November 2004
Resolved
Ballast pipe between #3 and #4 cargo hold leaking water. To be repaired prior to next US port after sailing foreign to the satisfaction of class.
Engineering › Sea-water System (primary cooling) › Piping
Issued 3 November 2004
Resolved
Multiple patches on piping for the #1 and #2 aux seawater cooling pumps for main generator. To be repaired prior to next US port after sailing foreign to the satisfaction of class.
Pollution Prevention/Response › Prevention Equipment
Issued 14 May 2002
Resolved
EXCESSIVE LEAK OF AIR COOLER CLEANER, A SURFACTANT, FROM THE AIR CHEM CLEANER PUMP. THESE CHEMICALS ARE IN THE BILGE. THE USE OF SURFACTANTS WILL RENDER THE OWS INOPERATIVE. CLASS TO TEST OWS AND VERIFY THAT THE DISCHARGE FROM THE OWS AND VERIFY THAT THE DISCHARGE FROM THE OWS IS LESS THAN 15PPM LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Navigation › Piloting/Steering
Issued 14 May 2002
Resolved
PROVIDE MISSING SAILING DIRECTIONS PUB 104 OR FOREIGN EQUIVALENT ASD 68 & 69 LEGACY COMPONENT DESC: SAILING DIRECTIONS
Engineering › Sea-water System (primary cooling)
Issued 14 May 2002
Resolved
SOFT PATCHES FOUND ON #2 AND #3 SHIP SERVICE GENERATORS SALT WATER COOLING PIPES IWO COOLER, 3 TOTAL
Fire Fighting › Fire Pumps
Issued 14 May 2002
Resolved
PORT FIRE PUMP LOCATED IN E-ROOM, CLAD WELDING FOUND ON DISCHARGE LEGACY COMPONENT DESC: DISCHARGE LINE
Engineering › Sea-water System (primary cooling)
Issued 14 May 2002
Resolved
#2 S/W COOLING PUMP PIPING FOR SHIP SERVICE GENERATOR . 2 SOFT PATCHES FOUND ON PUMP DISCHARGE, LOCATED IN LOWER E-ROOM LEGACY COMPONENT DESC: Piping
Engineering › Sea-water System (primary cooling)
Issued 14 May 2002
Resolved
SOFT PATCH ON OUTLET PIPE FOR DRAIN COOLER LOCATED NEXT TO VALVE WV-19 LEGACY COMPONENT DESC: Piping
Fire Fighting
Issued 3 May 2000
Resolved
REMOVE ALL COMBUSTIBLE MATERIALS FROM PAINT LOCKER PRIOR TO DEPARTURE.
Fire Fighting
Issued 3 May 2000
Resolved
PROVIDE REPAIRS TO FIRE MAIN PIPING PORT SIDE. TEMPORARY REPAIRS TO BE MADEPRIOR TO DEPARTURE TO SATISFACTION OF CLASS WITH PERMANENT REPAIRS TO BE MADE BY 03NOV00.
Fire Fighting
Issued 3 May 2000
Resolved
DEMONSTRATE SATISFACTORY FIRE DRILL TO USCG BOARDING OFFICER PRIOR TO DEPARTURE.
Construction/Loadline
Issued 3 May 2000
Resolved
REPAINT LOADLINE AT NEXT DRY DOCK.
Fire Fighting
Issued 28 December 1995
Resolved
SEVERAL SMOKE DETECTOR UNITS WERE COVERED IN PLASTIC (PAINTING HAD BEEN DONE DURING THE LAST YARD PERIOD), RENDERING THEM INOPERABLE. SOLAS 1974, CHAPTER II-2, REGULATION 13-1.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.