Records from 2001 to 2009. Most recent: inspection, 14 December 2009.
Inspection history · 29
14 December 2009
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3650132
16 July 2009
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3536669
28 March 2009
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3442698
28 March 2009
ISM Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3443596
25 March 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3605418
2 February 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3404095
13 November 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3362216
9 November 2008
ISPS III Exam · Ballast Water Examination · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3359852
29 September 2008
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3334961
27 September 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3333634
20 April 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3188007
20 April 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3199812
14 February 2008
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3147428
26 June 2007
Ballast Water Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2974963
21 April 2007
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2912191
5 August 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2736697
27 May 2006
ISPS II Exam · ILO-147 Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2657500
4 January 2004
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1974457
4 September 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1896832
19 March 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1759601
16 March 2003
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1757956
12 March 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1758500
21 January 2003
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1733293
18 November 2002
Annual Inspection · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1704168
15 February 2002
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1486803
13 February 2002
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1486473
13 February 2002
In-Service Inspection · MARPOL Annex I Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1486696
13 February 2002
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1609546
28 September 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 294211
Navigation › Piloting/Steering › Gyro Compass
Issued 9 November 2008
Resolved
During vessel's inbound transit to the port of Tampa, pilot reported to Sector St. Petersburg that the vessel's gyrocompass was inaccurate by 20 degrees. Class to attest to the proper operation of vessel's gyro compass.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 December 2008
Resolution: Received Satisfactory Class Report.
Navigation › Piloting/Steering › Gyro Compass
Issued 9 November 2008
Resolved
Vessel failed to report the inoperative gyro compass to the local Captain of the Port of Tampa.
Due 12 November 2008
Resolved 12 November 2008
Operations/Management › Navigation Safety › Arrival/Departure Tests
Issued 9 November 2008
Resolved
Vessel failed to conduct and log the reguired pre-arrival tests required by 33 CFR 164.25.
Due 12 November 2008
Resolved 12 November 2008
Resolution: Vessel logged the appropriate drills in the Engineers movement log but failed to log appropriate drills in the ship''s deck log. Master made appropriate entries into ships''s deck log.
Documentation › Certificates/Documents › IOPP Certificate
Issued 29 September 2008
Resolved
IOPP indicates vessel does not have an incinerator, however the vessel does have an incinerator installed. Vessel must make proper changes to IOPP to reflect incinerator to the satisfaction of the Certificate Issuing Authority.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 October 2008
Resolved 8 December 2008
Resolution: Vessel took the Incinerator out of service to comply with the IOPP
Lifesaving › Liferaft Equipment › Food Ration
Issued 29 September 2008
Resolved
Vessels Port and Starboard life boats do not have the required amount of food rations to accommodate the capacity of life boats. Vessel has 31 crew, 36 food rations in each of the life boats with capacity of 44 persons.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 October 2008
Resolved 12 November 2008
Resolution: Vessel purchased and placed new food rations for each life boat to ensure max capacity.
Engineering › Diesel Engine (propulsion-direct drive) › Blower, Centrifugal
Issued 20 April 2008
Resolved
While transiting inbound vessel blew a fuse on the no.2 ME blower causing the vessel to lose propulsion and steering. vessel is to submit a class report attesting the full and safe operation of the main engine.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 April 2008
Resolved 23 April 2008
Resolution: Received class report attesting the full and safe operation of the Main engine.
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, High Pressure (fuel injection)
Issued 26 June 2007
Resolved
The protective jacketing of the external high-pressure fuel delivery lines on cylinders #2, 3, 4, & 5 of the main diesel engine are not permanently assembled and have holes worn through.
Action required: 705 - Other - as specified
Due 3 July 2007
Resolved 28 June 2007
Resolution: Received class report attesting to the satisfactory completion of 5 deficiencies. According to class report Deficiency #5, 380V ground fault indicator is operable, but the scale is ineligible. GL imposed a Condition of Class, due 30Aug2007, new indicato
Electrical › Electric Generation Source (service) › Generator
Issued 26 June 2007
Resolved
The #1 main deisel generator has a water leak originating behind the fuel pump.
Action required: 705 - Other - as specified
Due 3 July 2007
Resolved 28 June 2007
Resolution: Received class report attesting to the satisfactory completion of 5 deficiencies. According to class report Deficiency #5, 380V ground fault indicator is operable, but the scale is ineligible. GL imposed a Condition of Class, due 30Aug2007, new indicato
Electrical › Electric Generation Source (service) › Generator
Issued 26 June 2007
Resolved
The shaft leading to the fuel pump on the main diesel generator is missing a protective shield.
Action required: 705 - Other - as specified
Due 3 July 2007
Resolved 28 June 2007
Resolution: Received class report attesting to the satisfactory completion of 5 deficiencies. According to class report Deficiency #5, 380V ground fault indicator is operable, but the scale is ineligible. GL imposed a Condition of Class, due 30Aug2007, new indicato
Operations/Management › Pollution › Control of Discharge of Oil
Issued 26 June 2007
Resolved
The placard stating "DISCHARGE OF OIL PROHIBITED" is painted over and is not legible.
Action required: 705 - Other - as specified
Due 3 July 2007
Resolved 28 June 2007
Resolution: Received class report attesting to the satisfactory completion of 5 deficiencies. According to class report Deficiency #5, 380V ground fault indicator is operable, but the scale is ineligible. GL imposed a Condition of Class, due 30Aug2007, new indicato
Electrical › Electric Generation Source (emergency) › Ground Detection
Issued 26 June 2007
Resolved
The 380V ground fault indicator on the emergency generator panel is inoperable.
Action required: 705 - Other - as specified
Due 3 July 2007
Resolved 28 June 2007
Resolution: Received class report attesting to the satisfactory completion of 5 deficiencies. According to class report Deficiency #5, 380V ground fault indicator is operable, but the scale is ineligible. GL imposed a Condition of Class, due 30Aug2007, new indicato
Fire Fighting › Structural Fire Protection - General
Issued 4 January 2004
Resolved
Automatic closing doors on emergency escape in forward engine room does not work properly in violation of SOLAS 74 amended, Chapter II-2, Regulation 47
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2004
Resolution: Item cleared by class
Lifesaving › Launching Appliances
Issued 4 January 2004
Resolved
The remote release on starboard lifeboat was inoperable in violation of SOLAS 74 amended, Chapter III, Regulatiion 20. LEGACY COMPONENT DESC: Release Mechanism
Condition: Improper/Lack of Maintenance
Due 11 January 2004
Resolved 6 January 2004
Resolution: Item cleared by class
Construction/Loadline › Penetrations
Issued 4 January 2004
Resolved
Closing devices on numerous sounding tubes not closing properly and some are missing in violation of ILLC 66. LEGACY COMPONENT DESC: Pipe Flange
Condition: Improper/Lack of Maintenance
Due 11 January 2004
Resolved 6 January 2004
Resolution: Item cleared by class
Engineering › Bilge Water Management System
Issued 4 January 2004
Resolved
Bilge alarms in engine room inoperable in violation of SOLAS 74 amended Chapter II-1, regulation 21.
Condition: Improper/Lack of Maintenance
Due 11 January 2004
Resolved 6 January 2004
Resolution: Item cleared by class
Engineering › Generator (propulsion/auxiliary-electric)
Issued 4 January 2004
Resolved
Generator cooling piping between supply pump on generator has a soft patch in violation of SOLAS 74 amended, Chapter II-1, Regulation 26.
Condition: Improper/Lack of Maintenance
Due 11 January 2004
Resolved 6 January 2004
Resolution: Item cleared by class
Engineering › Lubricating Oil Service System
Issued 4 January 2004
Resolved
Verify high pressure lube oil line repairs to the exaust valves meet manufacturer standards. SOLAS 74 amended, Chapter II-1, Regulation 26. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Due 11 January 2004
Resolved 6 January 2004
Resolution: Item cleared by class
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 4 January 2004
Resolved
Low insulation showing in 220 volt system in violation of SOLAS 74 amended, Chapter II-1, Reguation 45. LEGACY COMPONENT DESC: Ground Detection
Condition: Improper/Lack of Maintenance
Due 11 January 2004
Resolved 27 May 2006
Resolution: Repairs inspected by class society and confirmed repaired.
Navigation › Piloting/Steering › Gyro Compass
Issued 12 March 2003
Resolved
Vessel reported inoperable Gyro Compass. Inbound deviation granted.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2003
Resolved 17 March 2003
Resolution: Received report from technician attesting to repair of Gyro Compass. Vessel Cleared to sail.
Engineering › Freshwater System (jacketwater cooling)
Issued 21 January 2003
Resolved
#1 SS Gen sea cooling water piping (elbow) intact, was repaired by soft patch. Permanant repairs need to be made and tested to the satisfaction of Class (GL) LEGACY COMPONENT DESC: Piping
Condition: Placed in Improper Service
Due 28 January 2003
Resolved 22 January 2003
Resolution: Received report from class attesting to repairs. Vessel cleared to sail.
Engineering › Freshwater System (jacketwater cooling)
Issued 21 January 2003
Resolved
#2 SS Gen. sea water cooling intake piping (elbow) has a soft patch at the base of a pressure gage. Permanent repairs and testing of system are require of Class prior to the vessel getting U/W. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 21 January 2003
Resolved 22 January 2003
Resolution: Received report from class attesting to repairs. Vessel cleared to sail.
Lifesaving › Lifeboat
Issued 18 November 2002
Resolved
Make permanent repairs to the port side gunnel of the stbd lifeboat. LEGACY COMPONENT DESC: Fender
Condition: Unknown
Due 18 December 2002
Resolved 4 January 2004
Resolution: Item cleared
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 13 February 2002
Resolved
OWS system was unable to calibrate or control discharge of oily mixture when oil content in the effuent exceeds 15ppm. The discharge skin valve to the sea and the 3-way valve were found to be faulty. Repair and calibrate, unit to the satisfaction of class. Marpol Annex 1/19
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 14 February 2002
Resolved 14 February 2002
Resolution: OWS system was calibrated and repairs made to faulty valves.