MAURY USCG vessel records Sign in
← All vessels

MASS GLORY

MASS GLORY is a 1993 freight ship. The Coast Guard has recorded 25 inspections since 1993, most recently in January 2012, along with 13 deficiencies and 2 operational controls, 1 with no removal date recorded.

Records from 1993 to 2012. Most recent: inspection, 20 January 2012.

Built
1993
Last inspected
20 January 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9046916 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
392060
Flag
PANAMA
—
Maury page id
psix-392060

Inspections, by type

…with no type recorded14
Years with a record 18 calendar years (1993–2012)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it69555 - Dead Weight, Ton
79320 - Displacement, Ton
23007 - Convention (Subpart B), Net Ton
36560 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 25

20 January 2012 PII Safety Exam · Ballast Water Examination · ISPS I Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4222874
17 January 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4222876
8 August 2011 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4102030
12 October 2010 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3868522
29 December 2009 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3656445
18 February 2009 ISPS II Exam · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3419543
28 July 2008 PII Safety Exam · MARPOL Annex V Examination · ISPS III Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3284564
13 December 2007 PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3110771
9 December 2005 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2548940
22 June 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2399758
20 June 2005 ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2397680
15 November 2003 Ballast Water Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1942883
17 October 2002 Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1691567
4 June 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 290641
29 June 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 279315
6 August 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 431171
28 November 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 423007
12 December 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 485120
14 February 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 400557
18 July 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 393275
26 December 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 386253
21 May 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 378764
18 December 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 373364
18 December 1994 Uninspected Other
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1151852
2 August 1993 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 359837

Deficiency record · 13

Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 20 January 2012 Resolved
0111-Cargo ship Safety Construction: The port side step above the electrical conduit between cargo holds 4 and 5 were rusted and split, creating a hazard for the crew. Regulation- SOLAS 74(a) I/11.
Due 20 January 2012
Resolved 20 January 2012
Resolution: PSCO witnessed repair of step welded by crew.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 20 January 2012 Resolved
0830-Pipes wires (insulate) accident prev.- PSCO observed on deck between the 6 and 7 cargo hold a 10-inch crack between electrical pipe and the electrical junction box. Reference: SOLAS 74(a) II-1/45.
Due 20 January 2012
Resolved 20 January 2012
Resolution: PSCO observed crack welded by crew.
Engineering › Steam Boiler (auxiliary/waste heat) › Valve, Relief
Issued 20 January 2012 Resolved
1499-Other- Prop & Aux. Machinery: PSCO observed and heard a steam leak from the boiler steam valve. Regulation: SOLAS 74(a) II-1/45.
Action required: 705 - Other - as specified
Due 3 February 2012
Resolved 21 January 2012
Resolution: Received , reviewed and accepted class report from NKK stating the deficiency was rectified. NKK surveyor confirmed that steam valve gasket was replaced and observed valve operating under pressure with no leaks.
Fire Fighting › Remote Fuel Shutoff › General
Issued 10 August 2011 Resolved
0710- Oil fuel pipes from service tanks500L and above shall be fitted with a valve capable of being closed from outside the space in which the tank is situated. Emergency generator with 500L service tank lacks valve capable of being closed from outside the space. 74SOLAS (94 ConEd) II-2/15.2.5
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 January 2012
Resolution: PSCO witnessed crew test newly installed service tank valve closed from outside the space.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 February 2009 Resolved
An electrical lighting fixture on the second deck of the main engine has exposed wires posing an electrical shock hazard to the crew. SOLAS 2004 Cons., Ch. II-1, Reg. 45.1.3.
Due 18 February 2009
Resolved 18 February 2009
Resolution: Deficiency was corrected on site to the satisfaction of the USCG PSCO prior to the end of the exam.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 18 February 2009 Resolved
Multiple self-closing Cass A fire doors in machinery spaces were fitted with hold-back hooks that compromise SOLAS Class A fire boundaries. SOLAS 97 Cons., Ch. II-2, Reg.47.2.
Due 18 February 2009
Resolved 18 February 2009
Resolution: Deficiency was corrected on site to the satisfaction of the USCG PSCO prior to the end of the exam.
Construction/Loadline › Structures › Superstructure
Issued 18 February 2009 Resolved
A hole has been drilled completely through the vessel's superstructure on the starboard side boat deck next to the galley exhaust fan. The hole compromises the original SOLAS boundary set by Class in the SOLAS safety construction certificate. SOLAS 2004 Cons., Ch. II-1, Reg. 3-1.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 May 2009
Resolution: Received class report from Nippon [name withheld] stating that the hole was closed by means of welded plug.
Engineering › Steering Gear System › Ram Seal
Issued 18 February 2009 Resolved
Two buckets wre found under the steering gear packing glands. Both buckets were filled with hydraulic oil and during the operational test of the steering system, hydraulic oil was leaking from the packing glands. SOLAS 2004 Cons., Ch. 1, Reg. 11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 May 2009
Resolution: Received class report from Nippon [name withheld] stating that the oil leakages were sealed. Working test of steering gear was carried out with satisfactory results and all of steering gear area was cleaned.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 15 November 2003 Resolved
Update the oil transfer procedures to comply with 33CFR155.750 Prior to transfering after sailing foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 December 2005
Resolution: oil transfer procedures modified.
Lifesaving
Issued 18 July 1996 Resolved
PRIOR TO NEXT U.S. PORT REPAIR HANDRAIL ON PORT LIFEBOAT. RAIL IS BENT TO THE POINT THAT YOU CAN NOT GRAB OR HOLD ONTO IT, NEEDS TO BE PULLED AWAY FROM BOAT.
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Fire Fighting
Issued 18 December 1994 Resolved
Replace missing nozzles on weatherdeck firestations, prior to departing,_x001C_ per SOLAS chap. II reg 7.
Condition: Unknown
Due 18 December 1994
Resolved 19 December 1994
Fire Fighting
Issued 18 December 1994 Resolved
Remove all hold back devices on the fire doors to the stair ways, and steering gear room, prior to return to a U. S. port, per SOLAS chap II-2 Reg 47.
Condition: Unknown
Due 18 December 1994
Resolved 19 December 1994
Accommodation/Occupational Safety
Issued 18 December 1994 Resolved
Move personnel berthing in the hospital racks to their stateroom, and reserve rack for medical purposes, prior to departure, per ILO 147.
Condition: Unknown
Due 18 December 1994
Resolved 19 December 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.