PRIDE OF KEY WEST

PRIDE OF KEY WEST is a 1993 passenger vessel (inspected). The Coast Guard has recorded 54 inspections since 1994, most recently in November 2025, along with 78 deficiencies and 1 casualty investigation in 2011.

Records from 1994 to 2025. Most recent: inspection, 20 November 2025.

Built
1993
Last inspected
20 November 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCB4013
392157
Flag
UNITED STATES
367374050
Maury page id
psix-392157

Inspections, by type

…with no type recorded5
Years with a record 29 calendar years (1994–2025)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)60.1 ft × 28.2 ft × 6.8 ft
Registered tonnagegross 51 / net 41
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX BROTHERS ENTERPRISES INC · LOREAUVILLE, LA, UNITED STATES · built 1993
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationTwin Hull
Hailing portKEY WEST, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 25 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it51 - Simplified, Gross Ton
41 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCB4013MMSI 367374050 · active · compulsorily equipped · granted 27 September 2018, expires 29 September 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 54

20 November 2025 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8278029
15 May 2025 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8131561
18 November 2024 COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8027128
16 November 2023 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7836134
16 May 2023 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7686837
10 April 2023 In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7663400
2 November 2022 Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7586812
16 November 2021 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7351099
12 May 2021 Deficiency Check · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7194380
16 November 2020 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7054473
21 November 2019 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6860106
8 May 2019 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6678816
23 January 2019 DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6585479
31 January 2018 Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6355146
9 May 2017 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6131214
23 January 2017 DAPI Audit · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6075066
12 January 2016 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5796180
11 January 2016 Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5795238
12 January 2012 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4223616
2 December 2011 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4200503
14 January 2011 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3926467
11 January 2010 COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3662240
12 May 2009 Hull Examination · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3472404
14 January 2009 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3393854
7 June 2008 Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3326214
16 January 2008 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3131210
9 May 2007 Deficiency Check · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2920764
17 January 2007 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3078346
8 January 2007 In-Service Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2853423
18 January 2006 Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2567857
2 June 2005 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2376537
12 January 2005 COI Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2273002
30 January 2004 Re-Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1997525
28 May 2003 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1803038
14 February 2003 Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1753506
22 January 2003 MARPOL Annex V Examination · Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1722411
24 January 2002 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1480531
1 June 2001 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1445815
25 January 2001 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1471750
28 January 2000 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1440248
1 September 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1029300
2 June 1999 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1453623
4 February 1999 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1365069
13 February 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 777756
9 June 1997 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1431837
5 February 1997 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1096505
21 July 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 86738
9 July 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 26252
14 February 1996 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1185697
31 May 1995 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 875449
14 March 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 863527
22 February 1995 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1158605
9 March 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 854487
9 February 1994 Hull Examination · COI Inspection · Inclining Experiment · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401826

Deficiency record · 78

05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 November 2022 Resolved
Provide a valid NOAA Registration for the Cat 1, 406 MHz EPIRB.
Action required: 10 - Deficiency Rectified
Resolved 2 November 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 November 2022 Resolved
Replace 06 identified Type 1 adult life jackets.
Action required: 10 - Deficiency Rectified
Resolved 2 November 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 2 November 2022 Resolved
Replace the mid course of the starboard viewing port railing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 November 2022
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 November 2020 Resolved
Provide proof of enrollment in company’s drug testing program for crewmembers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 February 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 November 2020 Resolved
Provide 01 waterlight with lanyard and clip.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 February 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 November 2020 Resolved
Make anchor light operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 February 2021
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 16 November 2020 Resolved
Provide updated Coast Pilot.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 February 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 November 2019 Resolved
Demonstrate proper operation of fixed bilge system, upon testing the bilge de-watering capabilities in the Port Forward compartment the vessel was unable to create suction at bilge pickup. Fixed system is vessels primary means of dewatering.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2019
Resolution: cleared pipe, all sat
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 November 2019 Resolved
Replace wingnuts with permanent connections on both Port and STBD generator starting batteries.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 November 2019 Resolved
All cable and wires must be supported by metal supports spaced no more than 18inches apart in the Machinery Spaces. Zip ties may only be utilized for wire bundling and not supports.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 November 2019 Resolved
Electronic propulsion control systems must be designed so that a loss of power to the control system does not result in increased shaft speed or propeller pitch, as per 184.620(c). A propulsion control system drawing should be submitted along with a ‘Test Protocol’ to verify this. The Test Protocol should consist of a limited QFA and DVTP, only including analysis of the loss of power to the control system. Policy Letter MSC dated 07Jun17, provided by MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 December 2019
Resolution: conducted test
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 November 2019 Resolved
New 24volt electric starting system was installed at Dry dock. Submit the following to the local USCG for review: Elementary one-line diagram, Cable lists, Bills of materials, Type and capacity of storage batteries, Rating of circuit breakers and switches, and Load analysis. [email withheld] - Reference Vessel name and Official Number
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 January 2020
Resolution: Completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 January 2019 Resolved
Replace 10 Adult type 1 PFD's, PFD flotation material was wasted and no longer serviceable. Vessel is restricted to carrying 101 passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 February 2019
Resolution: New PFD's provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 January 2019 Resolved
Each lighting fixture must have a guard. Provide light cover for light under operating station or remove.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2019
Resolution: Light has been removed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 January 2019 Resolved
Properly secure painter line to Life Float painter attachment securing point on all 3 floats.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 February 2019
Resolution: Life floats secured with painter.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 January 2019 Resolved
Secure paddles for life floats.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 February 2019
Resolution: Paddles secured.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 January 2019 Resolved
Repair/replace 22 and 15 person Life-floats. Both Life-Floats have sun damage and are no longer international orange.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 February 2019
Resolution: Both life floats cleaned and repainted.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 23 January 2019 Resolved
Provide gaskets for ventilation covers for Port/STBD Engine rooms. Covers do not seat properly to secure air flow into E/R in the event of a fire.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 February 2019
Resolution: Gaskets provided for both sides.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 23 January 2019 Resolved
Provide means to ensure Engine Room vent covers stay closed when activation is required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 February 2019
Resolution: Brightly colored wingnuts provided (02 sets per door).
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 January 2019 Resolved
Post all pages of COI (03 pages) and Stability Letter (02 pages).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2019
Resolution: COI and Stability Letters posted.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 January 2019 Resolved
Post PFD donning placard on second deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2019
Resolution: Placard posted.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 January 2019 Resolved
Provide current publications (Coast Pilot [name withheld])
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2019
Resolution: Current publications onboard.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 January 2019 Resolved
Provide current Chart of area vessel is operated in, chart shall be of adequate scale for navigation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 February 2019
Resolution: Chart provided for area of operation.
Fire Fighting › Fire Pumps › Pressure
Issued 31 January 2018 Resolved
Fire pump needs to maintain sufficient stream. Vessel limited to 49 passengers.
Action required: 705 - Other - as specified
Due 6 February 2018
Resolved 31 January 2018
Resolution: Fire pump produced adequate stream.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 31 January 2018 Resolved
Renew identified 23 adult size PFDs. Vessel restricted to 91 total persons (type 1 PFD's).
Action required: 705 - Other - as specified
Due 6 February 2018
Resolved 31 January 2018
Resolution: New PFD's onboard.
Communications › Radio Communications › VHF Radiotelephone
Issued 31 January 2018 Resolved
Provide valid FCC safety certificate.
Action required: 705 - Other - as specified
Due 6 February 2018
Resolved 5 February 2018
Resolution: Received proof of a valid FCC safety cert.
Lifesaving › Lifefloat › Serviceable
Issued 31 January 2018 Resolved
Make repairs to life float and properly secure paddles.
Action required: 705 - Other - as specified
Due 6 February 2018
Resolved 5 February 2018
Resolution: Life float repaired iaw manufactures instructions.
Engineering › Steering Gear System › Hydraulic Hose
Issued 31 January 2018 Resolved
Secure hydraulic lines to starboard steering ram. (cooper tubing excessive flexing)
Action required: 705 - Other - as specified
Due 6 February 2018
Resolved 5 February 2018
Resolution: hydraulic hoses secured and chaffing gear applied.
Navigation › Piloting/Steering › Magnetic Compass
Issued 31 January 2018 Resolved
Renew light in magnetic compass.
Action required: 705 - Other - as specified
Due 6 February 2018
Resolved 15 February 2018
Resolution: light operational
Electrical › Electric Supply System (service) › Battery Installation
Issued 31 January 2018 Resolved
Secure port and STBD generator batteries.
Action required: 705 - Other - as specified
Due 6 February 2018
Resolved 5 February 2018
Resolution: Batteries secured.
Lifesaving › Lifefloat › Serviceable
Issued 23 January 2017 Resolved
Renew lifefloat (22 person). Vessel is restricted to carrying 74 passengers no more than 3NM from shore.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 9 March 2017
Resolution: Lifefloat replaced.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 23 January 2017 Resolved
At least one ring buoy shall not have a lifeline attached.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 26 January 2017
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 23 January 2017 Resolved
Stowage location for PFD's shall not have means of restricting access. Top deck compartments.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 9 March 2017
Resolution: Restricting device removed from PFD stowage location.
Communications › Radio Communications › VHF Radiotelephone
Issued 23 January 2017 Resolved
VHF radio shall have GPS integrated into installation.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 9 March 2017
Resolution: GPS integrated into VHF.
Fire Fighting › Fire Hoses › Connections
Issued 23 January 2017 Resolved
Provide spanner wrench for each fire station onboard (2).
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 9 March 2017
Resolution: Spanner wrench provided for both stations.
Engineering › Bilge Water Management System › Not Operational
Issued 23 January 2017 Resolved
Demonstrate operation of fixed power bilge pump system to attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2017
Resolution: [name withheld] and crew member were able to obtain adequate suction from powered bilge pump system with the port engine pump.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 23 January 2017 Resolved
Remove permanently installed extension cord in port engine room.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 9 March 2017
Resolution: Extension cord removed.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 23 January 2017 Resolved
Make all penetrations to watertight bulkheads watertight.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 30 March 2017
Resolution: Hi density foam used to make bulkhead watertight.
Engineering › Bilge Water Management System › Manifold
Issued 23 January 2017 Resolved
Properly label port and starboard bilge manifolds.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 9 March 2017
Resolution: Port and starboard bilge manifold labeled.
Lifesaving › Lifefloat › Paddle
Issued 23 January 2017 Resolved
Secure life float paddles to life float.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 26 January 2017
Navigation › Piloting/Steering › US Coast Pilot
Issued 12 January 2012 Resolved
Acquire updated Coast Pilot publication
Action required: 705 - Other - as specified
Due 19 January 2012
Resolved 12 January 2012
Resolution: Updated Coast Pilot publication acquired during the inspection.
Documentation › Logs/Records › Drug Test Records
Issued 12 January 2012 Resolved
Provide 2012 drug consortium list.
Action required: 705 - Other - as specified
Due 19 January 2012
Resolved 20 January 2012
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 12 January 2012 Resolved
Remove flammable liquids from engine space and store properly.
Action required: 705 - Other - as specified
Due 19 January 2012
Resolved 12 January 2012
Resolution: Flammable liquids were removed from engine space during the inspection.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 12 January 2012 Resolved
Install metal support clamps in engine room.
Action required: 705 - Other - as specified
Due 19 January 2012
Resolved 20 January 2012
Navigation › Piloting/Steering › Coast Guard Light List
Issued 14 January 2011 Resolved
Acquire updated Light List publication
Due 31 March 2011
Resolved 25 May 2011
Fire Fighting › Nozzles › Condition
Issued 14 January 2011 Resolved
Install approved nozzle for bow 1 1/2" fire hose
Due 21 January 2011
Resolved 21 January 2011
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 14 January 2011 Resolved
Remove plastic containers with flammable contents out of the engine room and properly store them.
Due 14 January 2011
Resolved 14 January 2011
Communications › Radio Communications › VHF Radiotelephone
Issued 14 January 2011 Resolved
Fill in emergency broadcast placard with vessel particulars
Due 14 January 2011
Resolved 14 January 2011
Navigation › Collision/Grounding Avoidance › Radar
Issued 11 January 2010 Resolved
Install FCC approved marine grade radar or request exemption in wiriting to OCMI.
Due 31 January 2010
Resolved 14 January 2011
Resolution: Vessel not required to have radar IAW old T regs.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 11 January 2010 Resolved
Acquire alcohol testing equipment to comply with 2hr testing requirement.
Due 14 January 2010
Resolved 14 January 2010
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 11 January 2010 Resolved
Post emergency broaddcast placard in a conspicuous location at operating station.
Due 14 January 2010
Resolved 21 January 2010
Lifesaving › Buoyant Apparatus › Marking
Issued 11 January 2010 Resolved
Label 15 man buoyant apparatus w/ vessel name.
Due 14 January 2010
Resolved 21 January 2010
Fire Fighting › Fire Hoses › Diameter
Issued 11 January 2010 Resolved
Install two 1.5 inch fire hoses on manifold to provide for adequate stream on fire s
Due 21 January 2010
Resolved 21 January 2010
Communications › Radio Communications › EPIRB
Issued 14 January 2009 Resolved
Replace battery in EPIRB or obtain a new EPIRB and register with NOAA. Vessel is restricted to 3 nm until this requirement is met.
Due 14 January 2009
Resolved 15 January 2009
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 14 January 2009 Resolved
Provide current proof of enrollment in drug and alcohol consortium.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2009
Resolved 16 January 2009
Navigation › Piloting/Steering › Marine Charts
Issued 7 June 2008 Resolved
Obtain current local nautical charts.
Due 7 June 2008
Resolved 7 June 2008
Lifesaving › Lifefloat › Paddle
Issued 16 January 2008 Resolved
Label vessel name on lifefloat paddles.
Due 30 January 2008
Resolved 30 January 2008
Personnel › Training › First Aid/CPR
Issued 16 January 2008 Resolved
Obtain first aid and CPR training for minimum of 50% of crew.
Due 30 January 2008
Resolved 30 January 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 16 January 2008 Resolved
Label bilge high level alarms at indicator panel.
Due 30 January 2008
Resolved 30 January 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 January 2008 Resolved
Label location of first aid kit.
Due 30 January 2008
Resolved 30 January 2008
Lifesaving › Hand Flares › Storage
Issued 16 January 2008 Resolved
Label location of distress flares.
Due 30 January 2008
Resolved 30 January 2008
Electrical › Electrical Distribution System (service) › Cable
Issued 9 May 2007 Resolved
Seal cable penetration through out the vessel.
Due 1 June 2007
Resolved 13 May 2009
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 8 January 2007 Resolved
Make proper repairs to the port A/C unit and provide a copy of the A/C technician servicing report prior to use.
Due 8 January 2007
Resolved 8 January 2007
Lifesaving › Lifefloat › Retroreflective Material
Issued 18 January 2006 Resolved
Replace retroreflective material on all lifefloats.
Action required: 705 - Other - as specified
Due 18 February 2006
Resolved 18 January 2006
Construction/Loadline › Hull › Bottom Plating
Issued 2 June 2005 Resolved
GRIND AND PAD WELD THE MARKED PIT DIRECTLY UNDER THE PORT SHAFT PACKING GLAND.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 June 2005
Resolved 2 June 2005
Resolution: REPAIR CORRECTED ON THE SPOT.
Lifesaving › Lifefloat › Lifeline
Issued 12 January 2005 Resolved
Replace lifelines in way of port side 22-man lifefloat.
Action required: 705 - Other - as specified
Due 13 February 2005
Resolved 21 January 2005
Lifesaving › Lifefloat › Painter
Issued 12 January 2005 Resolved
Replace painter in way of both 22-man lifefloats.
Action required: 705 - Other - as specified
Due 12 February 2005
Resolved 21 January 2005
Construction/Loadline › Hull › Bottom Plating
Issued 12 January 2005 Resolved
Replace cracked pane of 1 1/4" viewing glass in port pontoon, prior to completion of next credit dry-dock, 31 May 05.
Action required: 705 - Other - as specified
Due 31 May 2005
Resolved 2 June 2005
Engineering › Bilge Water Management System
Issued 22 January 2003 Resolved
Install visual high level bilge indicators in addition to the audible alarms at the operating station, in accordance with 46 CFR 182.530. To be corrected by 22Feb03 by an attending Marine Inspector. LEGACY COMPONENT DESC: Interface Detector
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 February 2003
Resolved 14 February 2003
Resolution: Visual High-level alarms installed.
Lifesaving › Lifebuoys
Issued 22 January 2003 Resolved
Renew retro-reflective tape on all ring lifebuoys not later than 22Feb03. LEGACY COMPONENT DESC: retro-reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 February 2003
Resolved 14 February 2003
Resolution: Retro-reflective tape has been replaced on all ring life-buoys.
Accommodation/Occupational Safety › Occupational Safety
Issued 22 January 2003 Resolved
Install netting mesh or additional course railing between the top rail and the bulwark so no space is greater than 4 inches where passengers have access to the rails not later than 22Mar03. LEGACY COMPONENT DESC: Deck Rail
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 22 March 2003
Resolved 3 April 2003
Resolution: Corrected.
Engineering › Bilge Water Management System › Valve
Issued 22 January 2003 Resolved
Ensure primary bilge pump is able to take suction from both port and starboard forward compartments not later than 23Feb03. *Additionally Master shall ensure that both forward compartments are visually examined for water every 20 minutes while underway.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2003
Resolved 23 January 2003
Resolution: Valve was frozen shut due to broken threaded lift for the gate valve. A new valve was installed. Item cleared.
Lifesaving › Rigid Liferafts
Issued 24 January 2002 Resolved
Replace worn retro-reflective tape on 22 person life float LEGACY COMPONENT DESC: Markings
Condition: Improper/Lack of Maintenance
Due 24 February 2002
Resolved 12 February 2002
Resolution: Replaced.
Documentation › Certificates/Documents
Issued 24 January 2002 Resolved
Vessel's COD was found invalid due to an administrative error where during the sale of the vessel FIRE BALL, the official number of the PRIDE OF KEY WEST was typed mistakenly for the official number of the FIRE BALL. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Due 24 February 2002
Resolved 24 January 2002
Resolution: Corrected by contacting the National Documentation Center.
Engineering
Issued 28 January 2000 Resolved
Replace gasket on stbd fuel tank hatch.
Condition: Unknown
Due 4 February 2000
Resolved 4 February 2000
Lifesaving
Issued 22 February 1995 Resolved
Post Emergency Check-off list in passenger area.
Condition: Unknown
Due 22 March 1995
Resolved 14 March 1995
Lifesaving
Issued 22 February 1995 Resolved
Replace weaklink on 15 man lifefloat with proper size.
Condition: Unknown
Due 22 March 1995
Resolved 14 March 1995
Lifesaving
Issued 22 February 1995 Resolved
Passenger capacity reduced to 110 persons maximum until 4 adult lifejacketsare repaired. (Retro-reflective material faded)
Condition: Unknown
Due 22 March 1995
Resolved 14 March 1995

Casualty record · 1

15 March 2011Routine · role: Involved in a Marine Casualty · 1 injured · activity 4112143
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.