Records from 2011 to 2025. Most recent: inspection, 20 November 2025.
Inspection history · 18
20 November 2025
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8278029
15 May 2025
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8131561
18 November 2024
COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8027128
16 November 2023
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7836134
16 May 2023
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7686837
10 April 2023
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7663400
2 November 2022
Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7586812
16 November 2021
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7351099
12 May 2021
Deficiency Check · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7194380
16 November 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7054473
21 November 2019
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6860106
8 May 2019
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6678816
23 January 2019
DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6585479
31 January 2018
Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6355146
9 May 2017
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6131214
23 January 2017
DAPI Audit · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6075066
12 January 2016
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5796180
11 January 2016
Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5795238
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 November 2022
Resolved
Provide a valid NOAA Registration for the Cat 1, 406 MHz EPIRB.
Action required: 10 - Deficiency Rectified
Resolved 2 November 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 November 2022
Resolved
Replace 06 identified Type 1 adult life jackets.
Action required: 10 - Deficiency Rectified
Resolved 2 November 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 2 November 2022
Resolved
Replace the mid course of the starboard viewing port railing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 November 2022
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 November 2020
Resolved
Provide proof of enrollment in company’s drug testing program for crewmembers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 February 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 November 2020
Resolved
Provide 01 waterlight with lanyard and clip.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 February 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 November 2020
Resolved
Make anchor light operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 February 2021
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 16 November 2020
Resolved
Provide updated Coast Pilot.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 February 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 November 2019
Resolved
Demonstrate proper operation of fixed bilge system, upon testing the bilge de-watering capabilities in the Port Forward compartment the vessel was unable to create suction at bilge pickup. Fixed system is vessels primary means of dewatering.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2019
Resolution: cleared pipe, all sat
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 November 2019
Resolved
Replace wingnuts with permanent connections on both Port and STBD generator starting batteries.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 November 2019
Resolved
All cable and wires must be supported by metal supports spaced no more than 18inches apart in the Machinery Spaces. Zip ties may only be utilized for wire bundling and not supports.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 November 2019
Resolved
Electronic propulsion control systems must be designed so that a loss of power to the control system does not result in increased shaft speed or propeller pitch, as per 184.620(c). A propulsion control system drawing should be submitted along with a ‘Test Protocol’ to verify this. The Test Protocol should consist of a limited QFA and DVTP, only including analysis of the loss of power to the control system. Policy Letter MSC dated 07Jun17, provided by MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 December 2019
Resolution: conducted test
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 November 2019
Resolved
New 24volt electric starting system was installed at Dry dock. Submit the following to the local USCG for review: Elementary one-line diagram, Cable lists, Bills of materials, Type and capacity of storage batteries, Rating of circuit breakers and switches, and Load analysis. [email withheld] - Reference Vessel name and Official Number
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 January 2020
Resolution: Completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 January 2019
Resolved
Replace 10 Adult type 1 PFD's, PFD flotation material was wasted and no longer serviceable. Vessel is restricted to carrying 101 passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 February 2019
Resolution: New PFD's provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 January 2019
Resolved
Each lighting fixture must have a guard. Provide light cover for light under operating station or remove.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2019
Resolution: Light has been removed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 January 2019
Resolved
Properly secure painter line to Life Float painter attachment securing point on all 3 floats.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 February 2019
Resolution: Life floats secured with painter.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 January 2019
Resolved
Secure paddles for life floats.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 February 2019
Resolution: Paddles secured.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 January 2019
Resolved
Repair/replace 22 and 15 person Life-floats. Both Life-Floats have sun damage and are no longer international orange.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 February 2019
Resolution: Both life floats cleaned and repainted.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 23 January 2019
Resolved
Provide gaskets for ventilation covers for Port/STBD Engine rooms. Covers do not seat properly to secure air flow into E/R in the event of a fire.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 February 2019
Resolution: Gaskets provided for both sides.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 23 January 2019
Resolved
Provide means to ensure Engine Room vent covers stay closed when activation is required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 February 2019
Resolution: Brightly colored wingnuts provided (02 sets per door).
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 January 2019
Resolved
Post all pages of COI (03 pages) and Stability Letter (02 pages).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2019
Resolution: COI and Stability Letters posted.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 January 2019
Resolved
Post PFD donning placard on second deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2019
Resolution: Placard posted.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 January 2019
Resolved
Provide current publications (Coast Pilot [name withheld])
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2019
Resolution: Current publications onboard.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 January 2019
Resolved
Provide current Chart of area vessel is operated in, chart shall be of adequate scale for navigation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 February 2019
Resolution: Chart provided for area of operation.
Fire Fighting › Fire Pumps › Pressure
Issued 31 January 2018
Resolved
Fire pump needs to maintain sufficient stream. Vessel limited to 49 passengers.
Action required: 705 - Other - as specified
Due 6 February 2018
Resolved 31 January 2018
Resolution: Fire pump produced adequate stream.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 31 January 2018
Resolved
Renew identified 23 adult size PFDs. Vessel restricted to 91 total persons (type 1 PFD's).
Action required: 705 - Other - as specified
Due 6 February 2018
Resolved 31 January 2018
Resolution: New PFD's onboard.
Communications › Radio Communications › VHF Radiotelephone
Issued 31 January 2018
Resolved
Provide valid FCC safety certificate.
Action required: 705 - Other - as specified
Due 6 February 2018
Resolved 5 February 2018
Resolution: Received proof of a valid FCC safety cert.
Lifesaving › Lifefloat › Serviceable
Issued 31 January 2018
Resolved
Make repairs to life float and properly secure paddles.
Action required: 705 - Other - as specified
Due 6 February 2018
Resolved 5 February 2018
Resolution: Life float repaired iaw manufactures instructions.
Engineering › Steering Gear System › Hydraulic Hose
Issued 31 January 2018
Resolved
Secure hydraulic lines to starboard steering ram. (cooper tubing excessive flexing)
Action required: 705 - Other - as specified
Due 6 February 2018
Resolved 5 February 2018
Resolution: hydraulic hoses secured and chaffing gear applied.
Navigation › Piloting/Steering › Magnetic Compass
Issued 31 January 2018
Resolved
Renew light in magnetic compass.
Action required: 705 - Other - as specified
Due 6 February 2018
Resolved 15 February 2018
Resolution: light operational
Electrical › Electric Supply System (service) › Battery Installation
Issued 31 January 2018
Resolved
Secure port and STBD generator batteries.
Action required: 705 - Other - as specified
Due 6 February 2018
Resolved 5 February 2018
Resolution: Batteries secured.
Lifesaving › Lifefloat › Serviceable
Issued 23 January 2017
Resolved
Renew lifefloat (22 person). Vessel is restricted to carrying 74 passengers no more than 3NM from shore.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 9 March 2017
Resolution: Lifefloat replaced.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 23 January 2017
Resolved
At least one ring buoy shall not have a lifeline attached.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 26 January 2017
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 23 January 2017
Resolved
Stowage location for PFD's shall not have means of restricting access. Top deck compartments.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 9 March 2017
Resolution: Restricting device removed from PFD stowage location.
Communications › Radio Communications › VHF Radiotelephone
Issued 23 January 2017
Resolved
VHF radio shall have GPS integrated into installation.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 9 March 2017
Resolution: GPS integrated into VHF.
Fire Fighting › Fire Hoses › Connections
Issued 23 January 2017
Resolved
Provide spanner wrench for each fire station onboard (2).
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 9 March 2017
Resolution: Spanner wrench provided for both stations.
Engineering › Bilge Water Management System › Not Operational
Issued 23 January 2017
Resolved
Demonstrate operation of fixed power bilge pump system to attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2017
Resolution: [name withheld] and crew member were able to obtain adequate suction from powered bilge pump system with the port engine pump.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 23 January 2017
Resolved
Remove permanently installed extension cord in port engine room.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 9 March 2017
Resolution: Extension cord removed.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 23 January 2017
Resolved
Make all penetrations to watertight bulkheads watertight.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 30 March 2017
Resolution: Hi density foam used to make bulkhead watertight.
Engineering › Bilge Water Management System › Manifold
Issued 23 January 2017
Resolved
Properly label port and starboard bilge manifolds.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 9 March 2017
Resolution: Port and starboard bilge manifold labeled.
Lifesaving › Lifefloat › Paddle
Issued 23 January 2017
Resolved
Secure life float paddles to life float.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 26 January 2017