MAURY USCG vessel records Sign in
← All vessels

GIBRALTAR

GIBRALTAR is a 1977 freight ship. The Coast Guard has recorded 34 inspections since 1993, most recently in March 2009, along with 24 deficiencies and 3 operational controls.

Records from 1993 to 2009. Most recent: inspection, 10 March 2009.

Built
1977
Last inspected
10 March 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7642663 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
392446
Flag
BELIZE
—
Maury page id
psix-392446

Inspections, by type

…with no type recorded15
Years with a record 13 calendar years (1993–2009)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it13485 - Convention (Subpart B), Gross Ton
13303 - Dead Weight, Ton
20350 - Displacement, Ton
4325 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 34

10 March 2009 MARPOL Annex I Examination · PII Safety Exam · ISPS III Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3428254
9 March 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3430359
24 December 2008 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3384601
23 December 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3390683
24 July 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3274783
20 July 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3273782
5 May 2008 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3195059
30 October 2007 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3089643
25 January 2007 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2861868
25 January 2007 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2861876
11 January 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2854344
22 February 2006 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2589653
1 November 2005 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2526069
25 May 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2368473
4 February 2005 PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2286513
15 November 2004 Random ISPS/MTSA/PSC · Deficiency Check · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2234539
12 July 2004 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2131099
11 May 2004 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2064981
28 April 2004 Ballast Water Examination · Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2050807
25 June 2003 Special Interest Vessel
Type not classified · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1826480
24 June 2003 Special Interest Vessel
Type not classified · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1825188
4 September 2002 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1670454
8 January 2002 Deficiency Check · Special Interest Vessel
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1476458
27 July 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 292307
11 July 1997 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 405437
21 October 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 396521
17 April 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 390063
12 January 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 386780
16 October 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 383675
24 July 1995 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 882852
18 July 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 66597
18 July 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 123780
27 February 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 375638
22 November 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 362453

Deficiency record · 24

Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 December 2008 Resolved
The vessel mast was damaged due to a allision with a bridge. The vessel is required to submit documentation attesting to the repair of the vessel mast and all effected vessel equipment caused by the allision. SOLAS 2004 Chapter I Reg. 11
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 December 2008
Resolution: The vessel submitted a class report attesting to the proper operation of the vessel mast and all effected vessel equipment caused by the allision.
Navigation › Collision/Grounding Avoidance › Radar
Issued 24 July 2008 Resolved
Independent Marine Radar was reported giving a No Sync and No Video alarm.
Action required: 705 - Other - as specified
Due 29 July 2008
Resolved 24 July 2008
Resolution: Received technician''s report satisfying the requirement.
Fire Fighting › Fire Main › Condition
Issued 11 January 2007 Resolved
All firehoses and associated piping to be tested by administration. Currently 3 fire stations are not operating properly, (main deck port side of superstructure). SOLAS Ch. II-1 Reg 3.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2007
Resolution: Inspectors boarded the vessel and check all fire hoses on board the ship. all tests sat.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 11 January 2007 Resolved
Vessel to provide Current Tables on board to the satisfaction of the U.S. Coast Guard. 33 CFR 164.30
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2007
Resolution: Vessel now has current tables on board
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 11 January 2007 Resolved
Gyro compass repeater on starboard side inoperable. Current set-up requires crew to continuously update heading to align with actual gyro compass. A certified technician is is required to calibrate to the satisfaction of the administration. 33CFR164.35(d) // SOLAS Ch. V Reg. 16
Condition: Design Flaw
Due 10 February 2007
Resolved 23 January 2007
Resolution: Inspectors boarded the vessel and verified correct operation of Gyro Compass.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 January 2007 Resolved
(DISREGARD COMPONENT) Reefer escape alarms not operating properly. Repair/Replace. SOLAS Ch. I Reg. 11
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 February 2007
Resolved 19 January 2007
Resolution: Inspectors tested ships reefer escape alarms.
Stability › Watertight Integrity › General
Issued 1 November 2005 Resolved
Hatch in deck, located in anchor winch compartment is wasted and holed. Class to attest to proper repairs, prior to next U.S. port after sailing foreign.
Action required: 15 - Rectify deficiencies by next port
Resolved 22 February 2006
Resolution: Received satisfactory class report.
Deck/Cargo › Ballast › Piping
Issued 1 November 2005 Resolved
Ballast pipe, located at top of access tunnel has two (2) soft patches. Class to attest to. Proper repairs, prior to next U.S. port after sailing foreign.
Action required: 15 - Rectify deficiencies by next port
Resolved 22 February 2006
Resolution: Received satisfactory class report.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 4 February 2005 Resolved
Personal protective guards missing in way of several fluorescent lighting fixtures located throughout the engine room. Some of the light fixtures are missing light bulbs creating a fire and shock hazard. The same discrepancy was noted back on 28APR04 by U.S. Coast Guard in Jacksonville, FL.
Action required: 705 - Other - as specified
Due 4 March 2005
Resolved 1 March 2005
Resolution: Received Class Report attesting to repairs.
Personnel › Certificates/Documents/Licenses › STCW Certificate, OIC of Navigational Watch
Issued 12 July 2004 Resolved
Navigation watch officers (Cheif mate, Master) show poor ability to speak and comprehend english. Rectify as necessary.
Action required: 705 - Other - as specified
Resolved 16 July 2004
Resolution: The navigation watch officers(Master, Chief Mate, 2nd Mate, 3rd Mate) successfully passed an oral exam of IMO Standard Marine Communication Phrases in English. The exam was conducted by [name withheld] and [name withheld].
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 12 July 2004 Resolved
Latest edition of 33 cfr not on board. Crew unfamiliar with U.S. regulations. Have on board prior to departure of next port of call.
Action required: 705 - Other - as specified
Resolved 16 July 2004
Resolution: Received report from class society attesting new editions of 33 CFR have been purchased and are on board the vessel.
Fire Fighting › Means of Escape › Doorways
Issued 12 July 2004 Resolved
Doors and hatches used during emergencies for escape are locked from the outside.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2004
Resolution: Received report from class society attesting necessary changes have been made.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 28 April 2004 Resolved
INSTALL PERSONAL PROTECTIVE GUARDS IN WAY OF ALL FLOURSENT LIGHTING IN THE ENGINE ROOM AND THE GALLEY. LEGACY COMPONENT DESC: FLOURSENT LIGHT COVERS
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 16 November 2004
Resolution: CORRECTED TO THE SATISFACTION OF THE MARINE INSPECTOR.
Lifesaving › Line-Throwing Appliances
Issued 28 April 2004 Resolved
PROVIDE ON BOARD THREE (3) ADDITIONAL CHARGES FOR THE LINE-THROWING APPLIANCE. LEGACY COMPONENT DESC: Projectiles
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2004
Resolved 4 May 2004
Resolution: RECEIVED E-MAIL FROM VESSELS AGENT THAT THE REQUIRED 4 LINE THROWING CHARGES ARE ON THE VESSEL (SEE ENCLOSED E-MAIL IN VESSEL FILE)
Construction/Loadline
Issued 27 July 2001 Resolved
REPAIR/RENEW AS ORIGINAL KNIFE EDGE ON WTD STARBOARD SIDE OF DECK HOUSE. PRIOR TO 27AUG01. ILLC 66 ANNEX I/15 (1270)
Condition: Unknown
Due 27 August 2001
Resolved 14 January 2002
Resolution: INSPECTED KNIFE EDGE ON WTD STARBOARD SIDE OF DECK HOUSE. KNIFE EDGE FOUND TO BE SATISFACTORY TO ENSURE WATERTIGHT INTEGRITY.
Lifesaving
Issued 27 July 2001 Resolved
LIFERAFTS TO BE SERVICED BY AN APPROVED SHORE SIDE FACILITY. SOLAS 74 AMENDED III/19.8.1 PRIOR TO DEPARTURE FROM PORT OF PASCAGOULA.
Condition: Unknown
Due 27 July 2001
Resolved 8 August 2001
Fire Fighting
Issued 27 July 2001 Resolved
PORTABLE AND FIXED FIRE FIGHTING EXTINGUISHERS TO BE SERVICED BY AN APPROVED SHORE SIDE FACILITY, PRIOR TO DEPARTURE FROM PORT OF PASCAGOULA. SOLAS 60 II/57(D)
Condition: Unknown
Due 27 July 2001
Resolved 8 August 2001
Construction/Loadline
Issued 11 July 1997 Resolved
DRAFT MARKS AND LOADLINE ARE NOT IN CONTRASTING COLOR TO HULL. REPAINT DRAFT MARKS AND LOADLINE IN CONTRASTING COLORS PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Engineering
Issued 12 January 1996 Resolved
IDENTIFY AND MAKE PERMANENT REPAIRS TO STEAM PIPING IN PIPE TUNNEL AND LOWER ENGINE ROOM LEVEL.
Condition: Unknown
Due 15 January 1996
Resolved 16 January 1996
Fire Fighting
Issued 12 January 1996 Resolved
MAKE PERMANENT REPAIRS TO DETERIORATED FIREMAIN PIPING ON MAIN DECK NEAR CARGO HOLD #1.
Condition: Unknown
Due 16 January 1996
Resolved 16 January 1996
Navigation
Issued 27 February 1995 Resolved
U.S. CHART 11329 OR FOREIGN EQUIV, NOT ON BOARD. AS PER 33 CFR 164.33(a)(1)
Condition: Unknown
Due 28 February 1995
Resolved 1 March 1995
Navigation
Issued 27 February 1995 Resolved
U.S. COAST GUARD LIGHT LIST OR FORGEIN EQUIV NOT ON BOARD. _x001C_ AS PER 33 CFR 164.33
Condition: Unknown
Due 28 February 1995
Resolved 1 March 1995
Navigation
Issued 27 February 1995 Resolved
U.S. TIDAL CURRENT TABLES WERE NOT ON BOARD,
Condition: Unknown
Due 28 February 1995
Resolved 1 March 1995
Navigation
Issued 22 November 1993 Resolved
LIGHT LIST WAS NOT ON BOARD.
Condition: Unknown
Due 26 November 1993
Resolved 26 November 1993

Ownership record