Records from 1993 to 2004. Most recent: inspection, 1 November 2004.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 20
1 November 2004
Administrative Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2232505
15 October 2004
Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2221489
7 August 2003
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1876082
30 June 2003
COI Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1827439
13 June 2003
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1910510
12 April 2001
COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1466217
31 August 2000
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1054623
2 September 1999
Deficiency Check · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1361123
19 August 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 214445
12 August 1998
Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1466546
20 August 1997
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 784282
15 July 1997
Deficiency Check · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1404413
10 June 1997
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1112467
17 October 1996
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1405985
24 September 1996
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 828025
19 August 1996
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1414683
11 September 1995
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1190004
21 August 1995
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1427102
23 August 1994
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1367156
19 August 1993
Hull Examination · Plan Review "T" Boat · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1434026
Engineering › Gasoline Engine (propulsion)
Issued 27 June 2003
Resolved
Replace both gasoline fuel lines between filters and fuel pumps. Hoses must be SAE J1942 and be rated for gasoline use. 46 CFR 182.720(e) Must be completed prior to carrying passengers. LEGACY COMPONENT DESC: Fuel Lines
Condition: Improper/Lack of Maintenance
Due 3 July 2003
Resolved 30 June 2003
Engineering › Gasoline Engine (propulsion)
Issued 27 June 2003
Resolved
Prove port main engine alternator is intrinsically safe/explosion proof or replace it with one that is. 46 CFR 182.410 Must be completed prior to carrying passengers. LEGACY COMPONENT DESC: Alternator (4 cycle)
Condition: Improper Installation
Due 3 July 2003
Resolved 3 July 2003
Resolution: New alternator installed.
Engineering › Gasoline Engine (propulsion)
Issued 27 June 2003
Resolved
Prove proper operation of flammable vapor detector in the engine compartment. 46 CFR 182.480
Must be completed prior to carrying passengers. LEGACY COMPONENT DESC: Flammable Vapor Detection System
Condition: Improper/Lack of Maintenance
Due 3 July 2003
Resolved 30 June 2003
Engineering › Bilge Water Management System
Issued 27 June 2003
Resolved
Change all hard plastic hoses installed on rule submersible bilge pumps with hose meeting 46 CFR 182.520(f). LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Due 27 July 2003
Resolved 30 July 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 27 June 2003
Resolved
Provide means to separate extra child-size life jackets stowed up fwd and re-label stowage to reflect their number and location. LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Due 27 July 2003
Resolved 7 August 2003
Documentation › Logs/Records
Issued 27 June 2003
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 27 July 2003
Resolved 30 July 2003
Navigation › Piloting/Steering
Issued 27 June 2003
Resolved
Provide current nav. charts for current area of operation and also a copy of nav. rules. LEGACY COMPONENT DESC: Marine Charts
Condition: Improper/Lack of Maintenance
Due 27 July 2003
Resolved 7 August 2003
Lifesaving › Hand Flares
Issued 27 June 2003
Resolved
Provide 3 hand-held red flares (46 CFR 185.614). Vessel is restricted to daylight operations until cleared. LEGACY COMPONENT DESC: Quantity
Condition: Improper/Lack of Maintenance
Due 3 July 2003
Resolved 30 June 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 27 June 2003
Resolved
Provide a complete/current first aid kit meeting 46 CFR 184.710. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 27 July 2003
Resolved 7 August 2003
Operations/Management › Drills/Instruction
Issued 27 June 2003
Resolved
Have vessel get underway to perform man-overboard drill and fire drill to the satisfaction of attending marine inspector. LEGACY COMPONENT DESC: Fire
Due 3 July 2003
Resolved 3 July 2003
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 27 June 2003
Resolved
Perform operational check of fixed extinguisher shut-down (main engines and blowers) and operation blower/engine start interlock. Must be done prior to carrying passengers. LEGACY COMPONENT DESC: Operating Controls
Due 3 July 2003
Resolved 30 June 2003
Communications › Radio Communications › VHF Radiotelephone
Issued 27 June 2003
Resolved
Provide proof of valid FCC marine radio operator's permit, FCC radio station license, and FCC radio safety telegraphy certificate. LEGACY COMPONENT DESC: Certificates
Condition: Improper/Lack of Maintenance
Due 15 September 2003
Resolved 1 November 2004
Resolution: Vessel no longer in Certified Service.
Documentation › Logs/Records
Issued 27 June 2003
Resolved
Provide log indicating crew training and drills conducted. LEGACY COMPONENT DESC: Crew Training/Drills
Due 27 July 2003
Resolved 30 July 2003
Lifesaving
Issued 12 April 2001
Resolved
Label all life jacket storage placards with number of life jackets. 46 CFR 180.78 and 46 CFR 176.800
Condition: Unknown
Due 10 May 2001
Resolved 10 May 2001
Engineering
Issued 12 April 2001
Resolved
Provide/install a vacuum hose from the port engine fuel pump to the Carburetor. 46 CFR 176.800
Condition: Unknown
Due 10 May 2001
Resolved 10 May 2001
Construction/Loadline
Issued 12 April 2001
Resolved
Provide a visual indicator light for all bilge pumps and high level alarms for the engine room and accomodation space bilges. 46 CFR 182.530
Condition: Unknown
Due 10 May 2001
Resolved 10 May 2001
Documentation
Issued 12 April 2001
Resolved
Provide all FCC licenses, permits, and certificates. 47 CFR
Condition: Unknown
Due 10 May 2001
Resolved 10 May 2001
Documentation
Issued 12 April 2001
Resolved
Provide valid vessel documentation. 46 CFR 67.7/67.9
Condition: Unknown
Due 10 May 2001
Resolved 10 May 2001
Fire Fighting
Issued 12 April 2001
Resolved
Provide 1 fire bucket for vessel. 46 CFR 181.610
Condition: Unknown
Due 10 May 2001
Resolved 10 May 2001
Electrical
Issued 12 April 2001
Resolved
Provide 2 portable lights for vessel. 46 CFR 183.430
Condition: Unknown
Due 10 May 2001
Resolved 10 May 2001
Fire Fighting
Issued 12 April 2001
Resolved
Provide vent closures for all engine room supply and exhaust vents. 46 CFR 182.460-470
Condition: Unknown
Due 10 May 2001
Resolved 10 May 2001
Construction/Loadline
Issued 12 April 2001
Resolved
Provide 1 hand bilge pump for vessel. 46 CFR 182.520
Condition: Unknown
Due 10 May 2001
Resolved 10 May 2001
Lifesaving
Issued 12 April 2001
Resolved
Provide emergency check-off list for vessel. 46 CFR 185.510 & 512
Condition: Unknown
Due 10 May 2001
Resolved 10 May 2001
Fire Fighting
Issued 2 September 1999
Resolved
PROVIDE HYDROSTATIC TESTING TO STBD SIDE PORTABLE EXTINGUISHER (46CFR175.810)
Condition: Unknown
Due 16 September 1999
Resolved 23 September 1999
Documentation
Issued 2 September 1999
Resolved
PROVIDE FCC RADIO STATION LIC ONBOARD.
Condition: Unknown
Due 16 September 1999
Resolved 23 September 1999
Construction/Loadline
Issued 2 September 1999
Resolved
REPAIR HIGH LEVEL BILGE ALARM INDICATOR AND INSTALL VISUAL INDICATOR AT OPERATING STATION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 September 1999
Resolved 23 September 1999
Engineering
Issued 2 September 1999
Resolved
PROVIDE GAS DETECTOR WITH AUDIABLE AND VISUAL ALARM IN ENGINE ROOM SPACE (182.480)
Condition: Unknown
Due 16 September 1999
Resolved 23 September 1999
Lifesaving
Issued 2 September 1999
Resolved
PROVIDE ONBOARD AN APPROVED FIRST AID KIT (184.710)
Condition: Unknown
Due 16 September 1999
Resolved 23 September 1999
Fire Fighting
Issued 2 September 1999
Resolved
PROVIDE SERVICING/INSPECTION TO PORTABLE AND FIXED FIRE FIGHTING SYSTEM (46CFR181.500).
Condition: Unknown
Due 16 September 1999
Resolved 23 September 1999
Unknown
Issued 12 August 1998
Resolved
PROVE OPERATIONAL TEST OF MAIN ENGINES, STEERING, AND BILGE SYSTEMS.
Condition: Unknown
Due 19 August 1998
Resolved 14 August 1998
Lifesaving
Issued 12 August 1998
Resolved
REPLACE RING LIFEBUOY._x001C_
Condition: Unknown
Due 19 August 1998
Resolved 14 August 1998
Unknown
Issued 15 July 1997
Resolved
PROVIDE DRIP PAN UNDER BOTH FUEL FILTERS IN ACCORDANCE WITH 46 CFR 182.455(b)(6).
Condition: Unknown
Due 15 July 1997
Resolved 15 July 1997
Unknown
Issued 19 August 1996
Resolved
CONDUCT SATISFACTORY MAN OVERBOARD DRILLS IN THE PRESENCE OF A MARINE INSPECTOR
Condition: Unknown
Due 19 August 1996
Resolved 19 August 1996
Electrical
Issued 19 August 1996
Resolved
PROPERLY INSTALL BONDING STRAP AT THE FLEXIBLE CONNECTION ON THE FUEL TANK FILL PIPE.
Condition: Unknown
Due 19 August 1996
Resolved 19 August 1996
Lifesaving
Issued 19 August 1996
Resolved
PROPERLY MARK RING BOUY WITH RETROREFLECTIVE MATERIAL
Condition: Unknown
Due 19 August 1996
Resolved 19 August 1996
Navigation
Issued 19 August 1996
Resolved
PROVIDE CURRENT FCC SAFETY CERTIFICATE FOR VESSEL
Condition: Unknown
Due 19 August 1996
Resolved 19 August 1996
Fire Fighting
Issued 19 August 1996
Resolved
PRIOR TO CARRYING PASSENGERS, PERFORM SATISFACTORY ANNUAL SERVICE ON FIXED FIREFIGHTING SYSTEM IN ENGINE ROOM.
Condition: Unknown
Due 19 August 1996
Resolved 19 August 1996
Accommodation/Occupational Safety
Issued 21 August 1995
Resolved
PROVIDE EMERGENCY CHECK-OFF SHEET FOR VESSEL'S OPERATION.
Condition: Unknown
Due 21 August 1995
Resolved 21 August 1995
Fire Fighting
Issued 21 August 1995
Resolved
HAVE FIXED HALON EXTINGUISHING SYSTEM UNDERGO ANNUAL SERVICING.
Condition: Unknown
Due 21 August 1995
Resolved 21 August 1995