Records from 1993 to 2017. Most recent: inspection, 7 July 2017.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 42
7 July 2017
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6201180
31 January 2010
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3673411
8 December 2009
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3646788
24 September 2008
Cargo Tank Internal · Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3331453
24 June 2008
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3246396
28 March 2008
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3172856
1 October 2007
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3070206
21 August 2006
Hull Examination · Cargo Tank Internal · Deficiency Check · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2741029
26 September 2005
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2501268
26 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2501583
16 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2293934
28 October 2004
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2230397
25 February 2004
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2013801
3 November 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979500
23 October 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1934281
13 November 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1704752
22 August 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415671
7 August 2001
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415664
22 March 2001
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1064685
19 January 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1376421
30 August 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1117391
27 August 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1361080
22 June 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1388845
19 November 1998
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 806443
10 September 1998
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1426125
15 January 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 178299
10 October 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1109636
4 September 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1113823
4 September 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1383656
16 August 1996
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443737
13 March 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 172062
14 September 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1456300
27 June 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1190023
6 February 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 834676
15 November 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389923
30 June 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1138099
22 March 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 856285
8 March 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 854871
2 March 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 856474
17 February 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1163300
17 September 1993
Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 832440
20 August 1993
Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 845745
Lifesaving › Line-Throwing Appliances › Lines
Issued 8 December 2009
Resolved
Provide extra messenger line to complete required 1,500 feet.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2009
Resolution: Rcvd fax with receipt and call from vsl rep stating it is on board.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 8 December 2009
Resolved
Provide one (1) extra line throwing device to complete total complement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2009
Resolution: Rcvd fax with reciept and call from vsl rep stating equipment onboard.
Fire Fighting › Fire Main › Pressure
Issued 24 September 2008
Resolved
Renew/ repair fire main pressure gauge on bridge.
Action required: 705 - Other - as specified
Due 3 November 2008
Resolved 3 October 2008
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 24 September 2008
Resolved
Renew/repair audible alarm in chief engineers stateroom.
Action required: 705 - Other - as specified
Due 3 November 2008
Resolved 3 October 2008
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 1 October 2007
Resolved
Renew exhaust lagging on bow thrusted due to exhaust leak.
Due 30 October 2007
Resolved 3 October 2007
Resolution: Captain of vessel verified correction of deficiency.
Engineering › Fuel Oil Service System › Piping
Issued 1 October 2007
Resolved
Install STOP SPRAY tape on hi-pressure fuel lines that are non-double jacketed; and flange covers on fuel system flanges in E/R.
Due 30 October 2007
Resolved 3 October 2007
Resolution: Installed required equipment.
Fire Fighting › Fire Main › Pressure
Issued 1 October 2007
Resolved
Renew fitting on pressure gauge line in engine room.
Due 30 October 2007
Resolved 1 October 2007
Resolution: Repaired fitting.
Fire Fighting › Remote Fuel Shutoff › General
Issued 1 October 2007
Resolved
Remote fuel shutoffs were found inoperable by ABS surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 October 2007
Resolution: ABS surveryor ([name withheld]) verified repairs of remote fuel shutoffs.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 21 August 2006
Resolved
Produce valid vessel certificate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2006
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 21 August 2006
Resolved
Post warning on Manuevering fact sheet
Action required: 705 - Other - as specified
Resolved 27 September 2006
Resolution: vsl not 1600 GT. Discrepancy cleared.
Communications › Alarms/Indicators › General Alarm
Issued 21 August 2006
Resolved
Post General alarm placards & CO2 alarm placards in accordance with 46 CFR 131.805 & 131.815
Due 21 September 2006
Resolved 27 September 2006
Navigation › Piloting/Steering › Magnetic Compass
Issued 21 August 2006
Resolved
Demonstrate proper operation of compass light.
Due 21 September 2006
Resolved 27 September 2006
Fire Fighting › Structural - A Class Divisions › Doors
Issued 21 August 2006
Resolved
Remove hold back devices from doors fore and aft of engine room.
Due 21 September 2006
Resolved 27 September 2006
Documentation › Markings/Placards › Official Number (US)
Issued 21 August 2006
Resolved
Permanently affix official number to bulkhead of engine room or other perminent structure IAW 46 CFR 67.121
Due 21 September 2006
Resolved 27 September 2006
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 21 August 2006
Resolved
Re-wrap exhaust blanket on port MDE
Due 21 September 2006
Resolved 27 September 2006
Fire Fighting › Means of Escape › Emergency Lighting
Issued 21 August 2006
Resolved
Mark emergency lighting with "E"
Due 21 September 2006
Resolved 1 October 2007
Resolution: Verified by attending marine inspector.
Electrical › Lighting (service) › Lighting Fixture
Issued 21 August 2006
Resolved
Replace lighting fixture in aft steering and engine room.
Due 21 September 2006
Resolved 27 September 2006
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 21 August 2006
Resolved
Label all controllers on bridge.
Due 21 September 2006
Resolved 21 August 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 21 August 2006
Resolved
Provide 3 or more dry chemical fire extinguishers on back deck IAW 46 CFR 98.30-37 (portable tanks).
Vessel not to carry cargo until F/F equipment is onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 September 2006
Resolved 1 October 2007
Resolution: Verified by attending marine inspector.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 21 August 2006
Resolved
Amend fire control plan without methanol and submit for approval.
Due 21 September 2006
Resolved 3 October 2008
Resolution: Provided new fire plans and were approved.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 21 August 2006
Resolved
Reconnect all CO2 cylinders prior to next voyage.
Due 21 September 2006
Resolved 21 August 2006
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 21 August 2006
Resolved
Perform auto test proceedures for fire pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2006
Communications › Radio Communications › EPIRB
Issued 23 October 2003
Resolved
Service EPIRB and renew hydrostatic release.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 November 2003
Resolved 29 October 2003
Deck/Cargo › Holds/Tanks
Issued 23 October 2003
Resolved
Replace or test (2) dry bulk relief valves. LEGACY COMPONENT DESC: Valve, Pressure Vacuum Relief
Action required: 705 - Other - as specified
Due 23 November 2003
Resolved 2 November 2003
Engineering › Compressed Air System (start air)
Issued 23 October 2003
Resolved
Replace stbd air receiver relief valve. LEGACY COMPONENT DESC: Receiver/Bottle
Action required: 705 - Other - as specified
Due 23 November 2003
Resolved 2 November 2003
Engineering › Fuel Oil Service System
Issued 23 October 2003
Resolved
Provide metal plug for Racor filter on tunnel thruster engine. LEGACY COMPONENT DESC: Filter
Action required: 705 - Other - as specified
Due 23 November 2003
Resolved 2 November 2003
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 October 2003
Resolved
Remove dead end wires on drop down thruster magnetic pick-up.
Action required: 705 - Other - as specified
Due 23 November 2003
Resolved 29 October 2003
Navigation › Emergency Steering
Issued 23 October 2003
Resolved
Make repairs to stbd shaft tachometer in aft steering. LEGACY COMPONENT DESC: Shaft Tachometer
Action required: 705 - Other - as specified
Due 23 November 2003
Resolved 29 October 2003
Engineering › Diesel Engine (auxiliary)
Issued 23 October 2003
Resolved
Make repairs to emergency generator over speed device. LEGACY COMPONENT DESC: Over speed Device
Action required: 705 - Other - as specified
Due 23 November 2003
Resolved 29 October 2003
Lifesaving › Launching Appliances › Davit
Issued 23 October 2003
Resolved
Provide and install chaffing gear for deck crane flexible hoses.
Action required: 705 - Other - as specified
Due 23 November 2003
Resolved 29 October 2003
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 23 October 2003
Resolved
Properly mark embarkation areas on both sides of the vessel.
Action required: 705 - Other - as specified
Due 23 November 2003
Resolved 29 October 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 23 October 2003
Resolved
Make repairs to port main engine exhaust cover bolts. LEGACY COMPONENT DESC: Piping (exhaust)
Action required: 705 - Other - as specified
Due 23 November 2003
Resolved 2 November 2003
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 23 October 2003
Resolved
Label the number of lifejackets on the outside of each stowage bin.
Action required: 705 - Other - as specified
Due 23 November 2003
Resolved 29 October 2003
Fire Fighting › Remote Fuel Shutoff
Issued 13 November 2002
Resolved
DEMONSTRATE PROPER OPERATION OF FUEL OIL AND LIQUID MUD PUMP REMOTE SHUT DOWNS. LEGACY COMPONENT DESC: REMOTE STOPS
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 December 2002
Resolved 13 November 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 13 November 2002
Resolved
DEMONSTRATE PROPER OPERATION OF OPERATING STATION PORT MAIN ENGINE STOP. LEGACY COMPONENT DESC: OPERATING STATION STOP
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 13 November 2002
Communications › Radio Communications
Issued 13 November 2002
Resolved
RENEW OR REPAIR SART. LEGACY COMPONENT DESC: SART
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 14 November 2002
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 13 November 2002
Resolved
MAKE PERMANENT REPAIRS TO PORT #5 BALLAST TANK LEAK.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 14 November 2002
Documentation
Issued 19 January 2001
Resolved
In stability manual: Remove #4 P/S ballast tank info, Add #3 P/S liq mud info on Loading Calc Sheet. Correct Tank Sounding Tables for same.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Documentation
Issued 19 January 2001
Resolved
Update stability software to reflect changes from #4 P/S ballast tank to _x001C_ #3 P/S liquid mud tanks.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Unknown
Issued 19 January 2001
Resolved
Verify tonnage and re-admeasure if necessary for the change of ballast tanks to liquid mud tanks.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Electrical
Issued 19 January 2001
Resolved
Provide approved plans and load analysis for installation of four liquid mud mixers, two in each of #3 liquid mud tanks.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Documentation
Issued 27 August 1999
Resolved
PROVIDE COPY OF GMDSS SHORE BASED MAINTENANCE AGREEMENT.
Condition: Unknown
Due 27 August 1999
Resolved 27 August 1999
Engineering
Issued 27 August 1999
Resolved
DEMONSTRATE PROPER OPERATION OF ENGINEERING AND FIRE DETECTION AUTOMATION SYSTEMS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 27 August 1999
Resolved 27 August 1999
Construction/Loadline
Issued 27 August 1999
Resolved
DEMONSTRATE PROPER OPERATION OF VSL'S OILY WATER SEPERATOR TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 27 August 1999
Resolved 27 August 1999
Documentation
Issued 10 September 1998
Resolved
Provide radio GMDSS service/installation report.
Condition: Unknown
Due 22 September 1998
Resolved 22 September 1998
Fire Fighting
Issued 10 September 1998
Resolved
Provide line diagram and more complete instructions for operation of CO2 systems onboard. Label pull station on bridge (what system).
Condition: Unknown
Due 10 September 1998
Resolved 14 September 1998
Fire Fighting
Issued 10 September 1998
Resolved
Provide lifeline with belt or a suitable harness for fireman outfits.
Condition: Unknown
Due 10 September 1998
Resolved 14 September 1998
Engineering
Issued 10 September 1998
Resolved
Remove plastic plugs from racor filters shields on port main engine, prior to departure.
Condition: Unknown
Due 10 September 1998
Resolved 14 September 1998
Fire Fighting
Issued 10 September 1998
Resolved
Provide fire main pressure guage, in pilot house, for emergency fire pump operations.
Condition: Unknown
Due 10 September 1998
Resolved 10 September 1998
Engineering
Issued 10 September 1998
Resolved
Prove proper operation of pilot house engine and shaft tachometers.
Condition: Unknown
Due 10 September 1998
Resolved 10 September 1998
Engineering
Issued 10 September 1998
Resolved
Prover proper operation of engineer's assist alarms horn in chief engineer's stateroom.
Condition: Unknown
Due 10 September 1998
Resolved 10 September 1998
Electrical
Issued 10 September 1998
Resolved
Secure fuel leaks on emergency generator prior to departure.
Condition: Unknown
Due 10 September 1998
Resolved 14 September 1998
Fire Fighting
Issued 10 September 1998
Resolved
Secure covers on and prove operation of blower shutdowns (pressure switches) on CO2 system for engine room and emergency generator room._x001C_ Covers on pressure switches not secured, missing screws.
Condition: Unknown
Due 10 September 1998
Resolved 14 September 1998
Documentation
Issued 14 September 1995
Resolved
PROVIDE APPROVED SOPEP
Condition: Unknown
Due 18 September 1995
Resolved 18 September 1995
Engineering
Issued 15 November 1994
Resolved
PROVIDE AUTOMATION SYSTEM TEST PROCEDURES FOR THE PROPER TESTING / OPERATION OF THE ENGINEERING AUTOMATED CONTROL / MONITORING SYATEM.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Navigation
Issued 17 September 1993
Resolved
DEVELOPE AND POST EMERGENCY STEERING INSTRUCTIONS AT THE PILOT HOUSE, CONTROL ROOM AND AFT STEERING CONTROL STATIONS.
Condition: Unknown
Due 17 September 1993
Resolved 17 September 1993
Navigation
Issued 17 September 1993
Resolved
PROVIDE DEVIATION CARD FOR MAGNETIC COMPASS MOUNTED IN THE PILOT HOUSE.
Condition: Unknown
Due 17 September 1993
Resolved 17 September 1993
Fire Fighting
Issued 17 September 1993
Resolved
PROVIDE ANUNCIATORS FOR THE FIRE DETECTION SYSTEM WHICH ARE UL LISTED UNDERUL464 OR UL1638 PER G-MSC-3 LETTER E-30448 DTD 09 AUG 93.
Condition: Unknown
Due 17 September 1993
Resolved 17 September 1993
Engineering
Issued 17 September 1993
Resolved
REPLACE PORT MAIN ENGINE TACHOMETERS ON THE AFT PILOT HOUSE AND THE AFT STEERING STATIONS.
Condition: Unknown
Due 17 September 1993
Resolved 17 September 1993
Fire Fighting
Issued 17 September 1993
Resolved
INSTALL FIRE MAIN PRESSURE GAUGES AT THE PILOT HOUSE AND CONTROL ROOM CONSOLES.
Condition: Unknown
Due 17 September 1993
Resolved 17 September 1993