Records from 2000 to 2009. Most recent: inspection, 21 July 2009.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 13
21 July 2009
Deficiency Check · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3541566
4 November 2005
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2528610
1 June 2005
ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2376197
10 December 2003
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1961676
24 July 2003
Security Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1855580
24 July 2003
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1856125
22 May 2003
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1799067
14 May 2003
Passenger/Freight Vessel Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1793393
21 September 2002
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1678385
21 September 2002
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1678389
22 February 2002
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1488490
15 September 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 293681
25 May 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 278254
Engineering › Steering Gear System › Hydraulic Hose
Issued 4 November 2005
Resolved
Steering gear room without non slip surface. SOLAS II-1 29.13.2
Condition: Unknown
Due 4 December 2005
Resolved 24 July 2009
Resolution: Non-slip surface was witnessed by attending PSCO to be applied in steering gear room.
Fire Fighting › Fire Pumps › Pressure
Issued 4 November 2005
Resolved
Discharge pressure gauge on main fire pump inoperative. SOLAS II-2/4
Condition: Unknown
Due 4 December 2005
Resolved 4 November 2005
Resolution: Cleared prior to disembarking vsl.
Construction/Loadline › Structures › Door
Issued 4 November 2005
Resolved
Two doors required to be weathertight on forward end of superstructure are wasted and holed. ICLL 12(1)
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 December 2005
Resolved 24 July 2009
Resolution: Two doors on the forward superstructure were witnessed by attending PSCO to be repaired.
Construction/Loadline › Structures › Deck Plating
Issued 4 November 2005
Resolved
Transverse walkway above weather deck immediately forward of deck house wasted through. ICLL 25-1(3)
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 December 2005
Resolved 24 July 2009
Resolution: Transverse walkways above weather deck were witnessed by attending PSCO to be repaired.
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 4 November 2005
Resolved
No evidence provided of static liquid pressure test of bunker line. 33 CFR 156.170
Condition: Unknown
Due 4 December 2005
Resolved 24 July 2009
Resolution: Static liquid pressure was stenciled on bunker line.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 4 November 2005
Resolved
One of the three fireman's outfits cannot be zipped up. Zipper keeps parting. SOLAS II-2/17
Condition: Unknown
Due 4 December 2005
Resolved 24 July 2009
Resolution: Required fireman outfits were inspected by attending PSCO were found to be in satisfactory condition.
Lifesaving › Lifeboat Equipment
Issued 10 December 2003
Resolved
VESSEL'S SART LOCATED IN THE FREE FALL LIFEBOAT WAS FOUND WITH AN EXPIRED BATTERY, A VIOLATION OF SOLAS 74/78, CH III REG 21/2.2. CORRECT PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: Radar Transponder
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 December 2003
Resolved 11 December 2003
Resolution: RECEIVED FAX ATTESTING TO PROOF OF PURCHASE OF NEW SART FROM VESSEL. DEFICIENCY CLEARED.
Navigation › Collision/Grounding Avoidance
Issued 14 May 2003
Resolved
Show operational recording device for echo depth sounder. LEGACY COMPONENT DESC: Echo-sounding Device Recorder
Action required: 705 - Other - as specified
Due 21 May 2003
Resolved 22 May 2003
Resolution: received class report stating def. was resolved
Electrical › Electrical Distribution System (service)
Issued 14 May 2003
Resolved
Provide nonconductive flooring behind main generator switchboard. LEGACY COMPONENT DESC: Non-conducting Deck Covering
Action required: 705 - Other - as specified
Due 20 May 2003
Resolved 22 May 2003
Resolution: received class report stating def. was resolved
Documentation › Certificates/Documents
Issued 21 September 2002
Resolved
CARGO SHIP SAFTEY EQUIPMENT CERTIFICATE EXPIRED. LEGACY COMPONENT DESC: Cargo Ship Safety Equipment Certificate
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2002
Resolved 23 September 2002
Resolution: FAXED COPY TO ACTBALT.