MAURY USCG vessel records Sign in
← All vessels

THOR SPRING

THOR SPRING is a 1993 freight ship. The Coast Guard has recorded 20 inspections since 1993, most recently in July 2008, along with 12 deficiencies and 1 operational control.

Records from 1993 to 2008. Most recent: inspection, 29 July 2008.

Built
1993
Last inspected
29 July 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9015670 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
393102
Flag
UKRAINE
—
Maury page id
psix-393102

Inspections, by type

…with no type recorded11
Years with a record 11 calendar years (1993–2008)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it2815 - Convention (Subpart B), Gross Ton
1532 - Convention (Subpart B), Net Ton
4063 - Dead Weight, Ton
5635 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

29 July 2008 MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · Deficiency Check · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3277616
28 July 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3282466
24 January 2007 MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2860973
19 August 2005 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2525399
18 July 2005 Enhanced Seaway Inspection (Massena only) · Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2425385
18 July 2005 Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2425388
4 April 2005 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2326391
28 December 2004 ISPS II Exam · PII Safety Exam · ILO-147 Exam · Ballast Water Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2265703
19 December 2003 Deficiency Check
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 1968556
2 August 2003 Annual Inspection · Security Inspection
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 1867600
23 October 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 283287
11 September 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 432703
23 July 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 418310
12 February 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 121828
12 February 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 412757
28 June 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 405248
23 January 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 399820
12 May 1996 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 391057
27 March 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 389448
23 August 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 360307

Deficiency record · 12

Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 24 January 2007 Resolved
During the inspection of the machinery spaces the PSCO found a temporary repair (soft patch) on the outtake pipe for the fresh water generator.
Action required: 705 - Other - as specified
Due 24 February 2007
Resolved 29 July 2008
Resolution: PSCO verified permanent repairs to outlet pipe have been made.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 28 December 2004 Resolved
Vessel does not have onboard a vessel specific ballast water mgmt plan. Provide a vessel specific ballast water mgmt plan prior to 28Jan05 to the satisfaction of the flag administration. 33CFR151.2035(a)(7) (Vessel is utilizing a company generic plan)
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 January 2005
Resolved 18 July 2005
Resolution: Def. cleared as per SLSDC inspector during ESI.
Operations/Management › Pollution › Control of Garbage
Issued 28 December 2004 Resolved
Vessel does not have onboard a vessel specific garbage mgmt plan. Provide a vessel specific garbage mgmt plan prior to 28Jan05 to the satisfaction of the flag administration. MARPOL 73/78 V/9 (2) (Vessel is utilizing a company generic plan)
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 January 2005
Resolved 19 August 2005
Resolution: Vessel has onboard a ship specific Garbage Management Plan. Cleared Deficiency.
Navigation › Piloting/Steering
Issued 2 August 2003 Resolved
Navigational chart being utilized for the Territory of American Samoa is outdated (old datum of 1927), and requires replacement w/a new edition and datum chart. LEGACY COMPONENT DESC: Marine Charts
Action required: 15 - Rectify deficiencies by next port
Due 2 September 2003
Resolved 19 December 2003
Navigation › Piloting/Steering
Issued 2 August 2003 Resolved
Missing the "warning statement" on the ship's maneuvering diagram. LEGACY COMPONENT DESC: Maneuvering Information Fact Sheet
Action required: 15 - Rectify deficiencies by next port
Due 2 September 2003
Resolved 19 December 2003
Lifesaving › Lifebuoys
Issued 2 August 2003 Resolved
Starboard bridgewing ring life buoy grab line around perimter of buoy is worn and deteriorated, requiring replacement. LEGACY COMPONENT DESC: Buoyant Lifeline
Action required: 15 - Rectify deficiencies by next port
Due 2 September 2003
Resolved 19 December 2003
Documentation › Safety/Response Plans/Programs
Issued 2 August 2003 Resolved
Shipboard Oil Pollution Emergency Plan is missing USCG contact information in Annex 2 for the U.S. Territory of American Samoa. LEGACY COMPONENT DESC: SOPEP
Action required: 15 - Rectify deficiencies by next port
Due 2 September 2003
Resolved 19 December 2003
Lifesaving › Inflatable Liferafts › Weak Link
Issued 2 August 2003 Resolved
Weak links for all 3 inflatable life rafts were improperly installed, preventing proper release and inflation.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 August 2003
Resolved 2 August 2003
Resolution: All 3 life raft weak links were properly connected from the cradle to the sea painter for proper inflation, with the raft holding straps connected separately.
Fire Fighting › Means of Escape
Issued 2 August 2003 Resolved
Entranceway to the CO2 room, and the emergency escape tunnel from the engine room, were blocked w/pollution prevention equipment and other materials. Some items temporarily moved during examination. All items are to be relocated to proper storage spaces and the corridors kept clear. LEGACY COMPONENT DESC: Corridors
Action required: 15 - Rectify deficiencies by next port
Due 2 September 2003
Resolved 19 December 2003
Engineering › Generator (propulsion-electric)
Issued 2 August 2003 Resolved
The Mega-Ohm indicator gauge on the emergency panel board for the 220V electrical system was reading in the "red" zone w/.8. Electrical problems are to be located and corrected; proper Mega-Ohm readings are to be shown. LEGACY COMPONENT DESC: Indicator Circuitry
Action required: 15 - Rectify deficiencies by next port
Due 2 September 2003
Resolved 19 December 2003
Engineering › Steering Gear System
Issued 2 August 2003 Resolved
Missing the steering gear block diagram in the steering gear space. LEGACY COMPONENT DESC: Steering Gear Block Diagram
Action required: 15 - Rectify deficiencies by next port
Due 2 September 2003
Resolved 19 December 2003
Engineering › Electric Propulsion System
Issued 2 August 2003 Resolved
Engineering Dept. missing lock-out & tag-out devices and a log book to ensure safety of personnel when working on electrical systems. LEGACY COMPONENT DESC: Lock-Out Tag-Out Procedures
Action required: 15 - Rectify deficiencies by next port
Due 2 September 2003
Resolved 19 December 2003
Resolution: Not required under cite specified. Master had an issue with this deficiency.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.