MAURY USCG vessel records Sign in
← All vessels

STRETCH DUCK 09

STRETCH DUCK 09 is a 1945 passenger vessel (inspected). The Coast Guard has recorded 48 inspections since 1993, most recently in August 2019, along with 24 deficiencies — 1 with no resolution recorded —.

Records from 1993 to 2019. Most recent: inspection, 19 August 2019.

Built
1945
Last inspected
19 August 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

393621
Flag
UNITED STATES
—
Maury page id
psix-393621

Inspections, by type

…with no type recorded3
Years with a record 24 calendar years (1993–2019)
The 48 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Simplified, Net Ton
4 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 48

19 August 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6787912
25 April 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6670287
8 February 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6622631
22 August 2018 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6519740
12 February 2018 Examination of Repairs · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6353728
8 December 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6321117
31 October 2016 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6042423
24 May 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5885505
8 December 2015 Hull Examination · Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5777727
21 September 2011 Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4161789
23 February 2011 Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3947174
1 September 2010 Examination of Repairs · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3925959
2 March 2010 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3685559
9 December 2009 In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3653009
24 March 2009 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3423268
26 August 2008 Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3309204
27 February 2008 Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3153407
23 April 2007 In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2913986
21 February 2007 Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2864170
30 March 2006 Examination of Repairs · COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2597757
7 April 2005 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2328646
8 March 2005 Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2293683
1 March 2005 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2301500
24 February 2004 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2000548
16 December 2003 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1965156
18 November 2003 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1951580
26 February 2003 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1739586
19 November 2002 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1707509
3 July 2002 Damage Survey · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1644225
1 July 2002 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1675101
6 March 2002 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1495180
30 January 2002 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1480402
23 May 2001 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1066581
15 April 2001 COI Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1422049
25 September 2000 Plan Review "T" Boat
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1462146
19 July 2000 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 821920
12 April 2000 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1439003
2 July 1999 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1084506
13 April 1999 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1451415
31 December 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 809912
9 September 1998 COI Inspection · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1473137
17 March 1998 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1109994
23 June 1997 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1112187
16 May 1996 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1392469
15 June 1995 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 878605
11 April 1995 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1172837
4 April 1994 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 857524
28 May 1993 Initial Certification · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 848550

Deficiency record · 24

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 February 2019 No resolution recorded
Prior to resuming vessel operations, company must demonstrate compliance with new conditions of operation listed on Amended COI to the satisfaction of attending Coast Guard marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Engineering › Pressure Vessel › Relief Valve
Issued 13 December 2017 Resolved
Relief valve set for 15 psi did not relieve within 10% of set pressure.
Action required: 705 - Other - as specified
Due 20 December 2017
Resolved 13 December 2017
Resolution: New relief valve installed and tested satisfactorily. Relieved at 15 psi.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 13 December 2017 Resolved
Engine compartment hood did not adequately seal when closure latch was activated. Significant gap along the port side of hood.
Action required: 705 - Other - as specified
Due 13 December 2017
Resolved 13 December 2017
Resolution: Gasket material was installed along the hood compartment sealing the gap and providing an adequate seal.
Construction/Loadline › Penetrations › Flange Pad
Issued 24 May 2016 Resolved
Exhaust penetration weld cracked due to impact.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2016
Resolved 24 May 2016
Resolution: Received email notification that repairs and testing were all sat.
Construction/Loadline › Hull › Hull Plating
Issued 26 August 2010 Resolved
Make perm repairs to wasted rear bilge pans.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2010
Resolved 1 September 2010
Resolution: Inspected repairs as per approved proposal.
Engineering › Pressure Vessel › Marking and Stamping
Issued 9 December 2009 Resolved
Prove proper installation of pressure vessels used for axel housing low air pressurization system.
Action required: 705 - Other - as specified
Due 9 January 2010
Resolved 21 September 2011
Resolution: System modified to reduce maximum pressure to 15 psi or less excluding unfired pressure vessel from requirement.
Construction/Loadline › Hull › Hull Plating
Issued 26 August 2008 Resolved
Properly repair the damage to the stbd side bow hull, stbd side bottom shell, centerline bottom sheel and front drive tube.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 September 2008
Resolved 1 September 2010
Resolution: Verified repair on old required def.
Construction/Loadline › Hull › Hull Plating
Issued 16 February 2005 Resolved
Make permanent repairs to hull in way of engine compartment on port side.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2005
Resolved 25 May 2005
Engineering › Gasoline Engine (propulsion)
Issued 16 December 2003 Resolved
Properly install engine space ventilation blower as per 46 CFR 182.460. LEGACY COMPONENT DESC: Ventilation
Condition: Improper Installation
Due 17 March 2004
Resolved 25 February 2004
Construction/Loadline › Hull
Issued 18 November 2003 Resolved
Make proper repairs to hull and pass float test in the presence of a Coast Guard inspector. LEGACY COMPONENT DESC: Bottom Plating
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2003
Resolved 25 February 2004
Engineering › Gasoline Engine (propulsion)
Issued 19 November 2002 Resolved
The change of engine is made in order to facilitate a more balanced engine for smoother performance, at the owner's request.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 March 2003
Resolved 10 March 2003
Engineering › Reduction Gearing/Clutches
Issued 3 July 2002 Resolved
HYDRAULIC PROP MOTOR MADE ABNORMAL NOISES AND VESSEL ENCOUNTERED A REDUCTION IN PROP OUTPUT. REPAIR OR REPLACE MOTOR TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. LEGACY COMPONENT DESC: Casing
Condition: Unknown
Due 3 July 2002
Resolved 10 July 2002
Electrical › Electric Generation Source (service)
Issued 30 January 2002 Resolved
Install overcurrent protection in the secondary battery conductor as required by 46 CFR 183.350(g) LEGACY COMPONENT DESC: Conductor
Condition: Design Flaw
Due 1 March 2002
Resolved 6 March 2002
Stability › Watertight Integrity
Issued 30 January 2002 Resolved
Prior to carrying passengers, provide proof of waterbourne test of forward boot assembly due to renewal
Condition: Unknown
Due 1 March 2002
Resolved 6 March 2002
Stability
Issued 30 January 2002 Resolved
Ensure reference mark is visible from the operator's station prior to carrying passengers.
Condition: Design Flaw
Due 1 March 2002
Resolved 6 March 2002
Lifesaving
Issued 30 January 2002 Resolved
Replace expired supplies in first aid kit.
Due 1 March 2002
Resolved 6 March 2002
Navigation
Issued 15 April 2001 Resolved
Repair or replace fractured rudder tiller arm.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Fire Fighting
Issued 15 April 2001 Resolved
Install closures, for CO2 flooding system, on all natural and power air vents.
Condition: Unknown
Due 15 April 2001
Resolved 15 April 2001
Engineering
Issued 9 September 1998 Resolved
PROPERLY LABEL LOCATION OF ALL THREE (3) FUEL SHUT OFF VALVES.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Construction/Loadline
Issued 9 September 1998 Resolved
APPLY OFFICIAL NUMBER TO VESSEL BOW.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Lifesaving
Issued 9 September 1998 Resolved
APPLY VESSEL NAME ON ALL PFD'S (LIFE JACKETS).
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Lifesaving
Issued 11 April 1995 Resolved
RENEW 60' LINE ATTACHED TO LIFE RING BUOY.
Condition: Unknown
Due 11 April 1995
Resolved 11 April 1995
Documentation
Issued 11 April 1995 Resolved
POST GARBAGE POLLUTION PLACARD ON BOARD.
Condition: Unknown
Due 6 March 2002
Resolved 6 March 2002
Navigation
Issued 11 April 1995 Resolved
PROVIDE ALL AROUND WHITE STERN LIGHT AND SEPARATE OPERATING POSITION FOR ANCHOR LIGHT OR REMOVE ALL NAVIGATION LIGHTS.
Condition: Unknown
Due 11 April 1995
Resolved 11 April 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.