MAURY USCG vessel records
← All vessels

STRETCH DUCK 09

STRETCH DUCK 09 is a 1945 passenger vessel (inspected). The Coast Guard has recorded 8 inspections since 2016, most recently in August 2019, along with 4 deficiencies — 1 with no resolution recorded —.

Records from 2016 to 2019. Most recent: inspection, 19 August 2019.

Built
1945
Last inspected
19 August 2019
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

393621
Flag
UNITED STATES
Maury page id
psix-393621

Inspections, by type

Years with a record 4 calendar years (2016–2019)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it4 - Simplified, Net Ton
4 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 8

19 August 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6787912
25 April 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6670287
8 February 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6622631
22 August 2018 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6519740
12 February 2018 Examination of Repairs · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6353728
8 December 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6321117
31 October 2016 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6042423
24 May 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5885505

Deficiency record · 4

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 February 2019 No resolution recorded
Prior to resuming vessel operations, company must demonstrate compliance with new conditions of operation listed on Amended COI to the satisfaction of attending Coast Guard marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Engineering › Pressure Vessel › Relief Valve
Issued 13 December 2017 Resolved
Relief valve set for 15 psi did not relieve within 10% of set pressure.
Action required: 705 - Other - as specified
Due 20 December 2017
Resolved 13 December 2017
Resolution: New relief valve installed and tested satisfactorily. Relieved at 15 psi.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 13 December 2017 Resolved
Engine compartment hood did not adequately seal when closure latch was activated. Significant gap along the port side of hood.
Action required: 705 - Other - as specified
Due 13 December 2017
Resolved 13 December 2017
Resolution: Gasket material was installed along the hood compartment sealing the gap and providing an adequate seal.
Construction/Loadline › Penetrations › Flange Pad
Issued 24 May 2016 Resolved
Exhaust penetration weld cracked due to impact.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2016
Resolved 24 May 2016
Resolution: Received email notification that repairs and testing were all sat.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.