Records from 1993 to 2026. Most recent: inspection, 10 June 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 40
10 June 2026
DAPI Audit · Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 8395482
9 May 2025
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 8128969
21 May 2024
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7916742
7 March 2024
In-Service Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7877316
6 February 2024
Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7862041
22 January 2024
Administrative Inspection
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7860592
12 September 2023
Administrative Inspection
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7800492
9 May 2023
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7685463
27 July 2022
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7519501
27 June 2021
Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7240249
27 May 2021
COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 7207162
14 May 2020
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6955054
23 April 2019
DAPI Audit · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6673438
16 August 2018
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6513636
1 August 2018
Administrative Inspection
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6497608
25 April 2018
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6399693
25 May 2017
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6162133
17 May 2016
DAPI Audit · Administrative Inspection · COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 5879237
22 May 2014
Drydock Exam · DAPI Audit · Internal Structural Exam · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4873148
7 May 2012
Annual Inspection · DAPI Audit · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4304488
7 February 2012
Simplified Stability Test · Administrative Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4240051
6 April 2009
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3447011
11 July 2008
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3264255
17 March 2008
COI Inspection · Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3165992
5 December 2007
Deficiency Check · Internal Structural Exam · In-Service Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3114018
23 March 2006
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2608194
4 January 2006
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2560416
21 March 2005
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2315433
8 November 2004
Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2256822
1 April 2004
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2035215
10 July 2003
Hull Examination · COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1797545
7 May 2003
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1778881
12 February 2003
Construction Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1740688
17 March 1998
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1109991
23 June 1997
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1112186
16 May 1996
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1470115
15 June 1995
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1188346
11 April 1995
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 859358
4 April 1994
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1167345
28 May 1993
Initial Certification · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1156537
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 January 2024
Resolved
Vessel is under going the modifications required by 46CFR175.124. Vessel will not be able to carry passengers in accordance with the COI until the requirements of the regulations are met.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2024
Resolution: Canopy and bilge system comply with 46CFR175.124.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 27 May 2021
Resolved
For fixed gas fire extinguishing systems, the inspections and tests required by 46CFR147.67, Each halocarbon cylinder forming part of a clean agent fixed fire extinguishing system must be: retested at least once every 12 years. Have fire suppression cylinders hydro tested by a qualified technician.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2021
Resolved 27 June 2021
Resolution: Replaced old fire fighting equipment and installed new fire fighting equipment - All Sat.
Construction/Loadline › Hull › Hull Plating
Issued 17 March 2008
Resolved
Wastage iwo port, aft steering compartment 2" below deck
Action required: 705 - Other - as specified
Due 24 March 2008
Resolved 24 March 2008
Resolution: Crop & re-new wastage
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 8 November 2004
Resolved
Relocate hinge assembly to allow clearance from the fwd rubber drive shaft boot.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 December 2004
Resolved 8 December 2004
Resolution: Deficiency corrected.
Stability › Watertight Integrity
Issued 7 May 2003
Resolved
Show proper repairs to area of forward drive tube and float test vessel in the presence of the attending marine inspector. LEGACY COMPONENT DESC: Hull plating at fwd drive tube
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2003
Resolved 10 July 2003
Lifesaving
Issued 16 May 1996
Resolved
HAND PUMP DISCHARGE HOSE WASN'T PERMANATLY ATTACHED TO THE PUMP AND IT WASN'T A THREADED CONNECTION. RECOMMENDED PVC PIPE SEALER BE APPLIED TO PERMANANTLY ATTACH HOSE CONNECTION TO PUMP.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Electrical
Issued 16 May 1996
Resolved
STARTING BATTERY TERMINALS WERE LOOSE AND CORRODED.
Condition: Unknown
Due 21 May 1996
Resolved 21 May 1996
Documentation
Issued 11 April 1995
Resolved
POST GARBAGE POLLUTION PLACARD ON BOARD.
Condition: Unknown
Due 11 April 1995
Resolved 11 April 1995
Lifesaving
Issued 11 April 1995
Resolved
PROVIDE APPROVED LIFE RING BUOY WITH 60' LINE ATTACHED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 11 April 1995
Resolved 11 April 1995
Construction/Loadline
Issued 11 April 1995
Resolved
PROVIDE PORTABLE HAND PUMP CAPABLE OF 5GPM OPERATION WITH SUITABLE LENGTHS OF SUCTION AND DISCHARGE HOSES PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 11 April 1995
Resolved 11 April 1995