Records from 1993 to 2009. Most recent: inspection, 6 April 2009.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 31
6 April 2009
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3447020
11 July 2008
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3264246
17 March 2008
COI Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3166039
5 December 2007
In-Service Inspection · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3110012
23 March 2006
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2608197
22 March 2005
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2316253
2 November 2004
Deficiency Check · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2254822
25 March 2004
Hull Examination · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2034236
5 August 2003
Hull Examination · COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1797553
9 June 2003
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1813417
27 February 2003
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1746645
11 June 2002
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1630497
8 May 2002
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1611868
9 April 2002
COI Inspection · Construction Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1490269
28 May 2001
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1066796
10 April 2001
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1461390
25 September 2000
Plan Review "T" Boat
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1462147
19 July 2000
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1053592
12 April 2000
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1460399
24 August 1999
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1114676
24 May 1999
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 805370
16 May 1999
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1424755
21 May 1998
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1127165
9 April 1998
Re-Inspection · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1431952
20 May 1997
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 775828
16 April 1997
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1383510
16 May 1996
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1470114
15 June 1995
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1188458
11 April 1995
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1170144
4 April 1994
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 857135
28 May 1993
Initial Certification · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1156808
Construction/Loadline › Hull › Side Shell
Issued 17 March 2008
Resolved
Fractured plate in way of stbd ladder stop bracket. Crop and renew affected area.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 March 2008
Resolved 20 March 2008
Resolution: Corrected
Construction/Loadline › Hull › Side Shell
Issued 17 March 2008
Resolved
Pinhole from weld arc in upper side shell at gunwale, port side 2 feet fwd of stern. Repair same.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 March 2008
Resolved 20 March 2008
Resolution: Corrected
Communications › Alarms/Indicators › General Alarm
Issued 17 March 2008
Resolved
Aft vapor detection sensor not mounted.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 March 2008
Resolved 20 March 2008
Resolution: Corrected
Construction/Loadline › Hull › Hull Plating
Issued 5 December 2007
Resolved
Stbd side below water line, small hole iwo stbd side rear wheel well.
Action required: 705 - Other - as specified
Due 5 January 2008
Resolved 17 December 2007
Resolution: Corrected
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 2 November 2004
Resolved
Grind away material from rear hinge assembly to allow clearance of rubber boots.
Due 4 November 2004
Resolved 4 November 2004
Engineering › Bilge Water Management System › Interface Detector
Issued 2 November 2004
Resolved
Secure port bilge float switch.
Due 4 November 2004
Resolved 4 November 2004
Electrical › Electrical Distribution System (service)
Issued 9 April 2002
Resolved
Provide updated directory for electrical panel. LEGACY COMPONENT DESC: Panelboard
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 May 2002
Resolved 8 May 2002
Electrical › Electrical Distribution System (service)
Issued 9 April 2002
Resolved
Identify battery hot fuses in electrical panel LEGACY COMPONENT DESC: Panelboard
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 May 2002
Resolved 8 May 2002
Engineering › Gasoline Engine (propulsion) › Battery (4 cycle)
Issued 9 April 2002
Resolved
Install proper amp-hr battery, min 100 amp. reserve power.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 May 2002
Resolved 11 April 2002
Construction/Loadline › Hull
Issued 9 April 2002
Resolved
Crop out and renew Hat Channel in aft port wheel well. LEGACY COMPONENT DESC: Stiffener
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 May 2002
Resolved 8 May 2002
Engineering › Bilge Water Management System › Pump
Issued 9 April 2002
Resolved
Make proper repairs to aft port bilge pump.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 May 2002
Resolved 9 April 2002
Fire Fighting
Issued 10 April 2001
Resolved
INSTALL VENT CLOSURES ON ALL SUPPLY AND EXHAUST VENTS.
Condition: Unknown
Due 10 April 2001
Resolved 10 April 2001
Construction/Loadline
Issued 10 April 2001
Resolved
REPAIR OR PLUG SMALL HOLES IN THE PORT SIDE, AMIDSHIPS, UPPER GUNWALE AREA.
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Navigation
Issued 10 April 2001
Resolved
PROPERLY ADJUST THE RUDDER POST PACKING NUT.
Condition: Unknown
Due 10 April 2001
Resolved 10 April 2001
Fire Fighting
Issued 10 April 2001
Resolved
PROVE PROPER OPERATION OF THE AFT VAPOR DETECTOR.
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Construction/Loadline
Issued 10 April 2001
Resolved
REPAIR OE REPLACE FIRST FLOOR FRAME, FWD OF THE PORT SIDE, AFT WHEEL WELL.
Condition: Unknown
Due 10 April 2001
Resolved 10 April 2001
Construction/Loadline
Issued 16 May 1999
Resolved
Install high bilge alarm.
Condition: Unknown
Due 16 May 1999
Resolved 16 May 1999
Engineering
Issued 16 May 1999
Resolved
Install vapor detection system.
Condition: Unknown
Due 16 May 1999
Resolved 16 May 1999
Engineering
Issued 9 April 1998
Resolved
Install shut off valve at fuel tank.
Condition: Unknown
Due 9 April 1998
Resolved 9 April 1998
Lifesaving
Issued 9 April 1998
Resolved
Replace retro tape on 1 adult and 2 child size PFDs.
Condition: Unknown
Due 9 April 1998
Resolved 9 April 1998
Navigation
Issued 9 April 1998
Resolved
Replace or repair aft nav light.
Condition: Unknown
Due 9 April 1998
Resolved 9 April 1998
Construction/Loadline
Issued 9 April 1998
Resolved
Prove proper operation of stbd electric bilge pump
Condition: Unknown
Due 9 April 1998
Resolved 9 April 1998
Engineering
Issued 16 April 1997
Resolved
Properly mark emergency fuel shut off valve.
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Construction/Loadline
Issued 16 April 1997
Resolved
Properly apply hull numbers when painting operation is completed.
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Documentation
Issued 11 April 1995
Resolved
POST GARBAGE POLLUTION PLACARD ON BOARD.
Condition: Unknown
Due 11 April 1995
Resolved 11 April 1995
Engineering
Issued 4 April 1994
Resolved
CORRECT FUEL LEAK IN ENGINE COMPARTMENT (CARBURATOR) PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 5 April 1994
Resolved 11 April 1994
Construction/Loadline
Issued 4 April 1994
Resolved
OPERATIONALLY TEST AFT STBD BILGE PUMP.
Condition: Unknown
Due 5 April 1994
Resolved 11 April 1994