Records from 1993 to 1999. Most recent: inspection, 5 January 1999.
Inspection history · 15
5 January 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 729364
5 November 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 210583
9 October 1998
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 421269
15 April 1998
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 414859
1 April 1998
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 414345
11 March 1998
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 413484
22 January 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 399674
19 January 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 399667
22 December 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 373668
22 December 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1158253
20 December 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 373570
1 December 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 645400
16 November 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 12426
16 November 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 470113
26 August 1993
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 360461
Lifesaving
Issued 11 March 1998
Resolved
STARBOARD LIFE BOAT LIMIT SWITCH FOR THE BOAT DAVIT IS INOPERABLE. REPAI/RENEW AND PROVIDE CLASS REPORT PRIOR TO RETURN TO U.S. WATERS.
Condition: Unknown
Due 1 April 1998
Resolved 1 April 1998
Fire Fighting
Issued 11 March 1998
Resolved
FOAM EXTINGUISHER FOR ENGINE ROOM CONDEMNED. REPAIR/RENEW AND PROVIDE SERVICING REPORT PRIOR TO RETURN TO U.S. WATERS.
Condition: Unknown
Due 1 April 1998
Resolved 1 April 1998
Fire Fighting
Issued 11 March 1998
Resolved
50 LB CO2 PIPE TO ENGINE MISSING SEAL. SERVICE AND PROVIDE SERVICING REPORT BY 11APR98 OR PRIOR TO RETURN TO U.S. WATERS.
Condition: Unknown
Due 1 April 1998
Resolved 1 April 1998
Lifesaving
Issued 11 March 1998
Resolved
PORT AND STARBOARD LIFERAFTS WERE NOT ONBOARD (OUT FOR SERVICING). PROVIDELIFERAFTS AND SERVICING REPORT ONBOARD PRIOR TO DEPARTURE.
Condition: Unknown
Due 11 March 1998
Resolved 12 March 1998
Electrical
Issued 11 March 1998
Resolved
#3 GENERATOR HAS A HOSE CONNECTING TO CRANKCASE BREATHER TO AN INSTALLED EXHAUST VENT. GENERATOR SMOKES FROM THE #2 & #3 CYLINDER. REPAIR/RENEW ANDPROVIDE CLASS REPORT.
Condition: Unknown
Due 11 April 1998
Resolved 15 April 1998
Navigation
Issued 11 March 1998
Resolved
STARBOARD RADAR IS INOPERABLE. REPAI/RENEW AND PROVIDE SERVICING REPORT.
Condition: Unknown
Due 1 April 1998
Resolved 1 April 1998
Lifesaving
Issued 11 March 1998
Resolved
FREEZER DOOR EMERGANCY HANDLE RELEASE MISSING. REPAIR OR RENEW.
Condition: Unknown
Due 1 April 1998
Resolved 1 April 1998
Lifesaving
Issued 19 January 1997
Resolved
Life buoy self igniting light inoperative. SOLAS 74/78 III/R7.1.3
Condition: Unknown
Due 19 January 1997
Resolved 20 January 1997
Lifesaving
Issued 19 January 1997
Resolved
Lifeboat motor inoperative. SOLAS 74/78 III/R19&26.
Condition: Unknown
Due 20 January 1997
Resolved 20 January 1997
Lifesaving
Issued 19 January 1997
Resolved
Life raft weaklinks installed improperly. SOLAS 74/78 III/R29.
Condition: Unknown
Due 19 January 1997
Resolved 20 January 1997
Navigation
Issued 19 January 1997
Resolved
U.S. Inland Rules of the Road missing. SOLAS 74/78 V R20.
Condition: Unknown
Due 19 January 1997
Resolved 20 January 1997
Electrical
Issued 19 January 1997
Resolved
Light fixture globes and cages missing. SOLAS 74/48 II-1/R45.10
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998
Fire Fighting
Issued 20 December 1994
Resolved
THE VESSEL IS TO REPLACE THE PATCHED SECTION OF THE FIRE MAIN ON THE MAIN DECK FWD
Condition: Unknown
Due 20 January 1997
Resolved 20 January 1997
Lifesaving
Issued 20 December 1994
Resolved
THE VESSEL IS TO REPLACE ALL SPOILED RATIONS IN THE PORT SIDE LIFERAFT. A PORTION OF THE RATIONS HAD GOTTEN WET AND THE PACKAGING HAD DETERIATED.
Condition: Unknown
Due 20 January 1997
Resolved 20 January 1997
Navigation
Issued 20 December 1994
Resolved
THE VESSEL IS TO PROVIDE THE "WARNING STATMENT" ON IT'S MANUVERING FACT SHEET.
Condition: Unknown
Due 26 December 1994
Resolved 26 December 1994
Lifesaving
Issued 20 December 1994
Resolved
FTHE VESSEL IS TO PROVIDE WEAKLINKS FOR BOTH LIFERAFTS.
Condition: Unknown
Due 26 December 1994
Resolved 26 December 1994
Navigation
Issued 20 December 1994
Resolved
THE VESSEL IS TO PROVIDE CURRENT COPIES OF U.S. COAST PILOT, LIGHT LIST, TIDE TABLES, AND TIDAL CURRENT TABLES.
Condition: Unknown
Due 26 December 1994
Resolved 26 December 1994