MAURY USCG vessel records Sign in
← All vessels

CHERAMIE WRENN

CHERAMIE WRENN is a 2002 freight ship. The Coast Guard has recorded 35 inspections since 2002, most recently in February 2026, along with 29 deficiencies and 1 operational control.

Records from 2002 to 2026. Most recent: inspection, 10 February 2026.

Built
2002
Last inspected
10 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8975287 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDP8746
Flag
UNITED STATES
368357320
Maury page id
psix-39396

Inspections, by type

…with no type recorded3
Years with a record 22 calendar years (2002–2026)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Registered dimensions (L × B × D)154.4 ft × 46.0 ft × 13.0 ft
Registered tonnagegross 93 / net 63
ITC dimensions (L × B × D)154.4 ft × 46.0 ft × 13.0 ft
ITC tonnagegross 701 / net 210
BuilderMASTER BOAT BUILDERS INC · BAYOU LA BATRE, AL, UNITED STATES · built 2002
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 21 March 2026 · expires 31 March 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it63 - Regulatory (Subpart C or D), Net Ton
210 - Convention (Subpart B), Net Ton
93 - Regulatory (Subpart C or D), Gross Ton
701 - Convention (Subpart B), Gross Ton
850 - Dead Weight, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP8746MMSI 368357320 · active · compulsorily equipped · granted 6 November 2024, expires 6 November 2034
WDP4749MMSI 368357320 · cancelled · compulsorily equipped · granted 13 March 2024, cancelled 4 November 2024 · licensed under a name not among this hull’s recorded names (not shown)
WDJ2059MMSI 367608620 · cancelled · compulsorily equipped · granted 17 September 2016, cancelled 26 February 2024 · licensed under a name not among this hull’s recorded names (not shown)
WDH3565MMSI 367608620 · cancelled · compulsorily equipped · granted 6 March 2014, cancelled 15 September 2016 · licensed under a name not among this hull’s recorded names (not shown)
WDA6993MMSI 366838350 · cancelled · compulsorily equipped · granted 19 January 2012, cancelled 27 January 2014 · licensed under a name not among this hull’s recorded names (not shown)
WDA8101MMSI 366850660 · cancelled · compulsorily equipped · granted 4 May 2002, cancelled 28 May 2002 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

JONI Offshore Supply Vessel · MISLE 799249 · 29 May 2014 · activity 4880215

Inspection history · 35

10 February 2026 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8308803
30 April 2025 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8111431
18 February 2025 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8080572
13 March 2024 Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7878366
8 February 2024 Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7862993
25 January 2023 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7626720
15 September 2022 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7559953
23 November 2021 Drydock Exam · Cargo Tank Internal · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7356814
18 March 2021 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7158321
4 May 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6947793
29 March 2019 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6652063
21 March 2019 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6646462
25 April 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6399513
8 December 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6321021
11 January 2017 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6068878
27 December 2016 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6062782
20 April 2016 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5861814
29 May 2014 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4877090
29 May 2014 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4880215
7 May 2014 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4856687
10 March 2014 Cargo Tank Internal · Administrative Inspection · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4811736
18 January 2012 Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4235864
1 February 2011 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3937180
23 March 2009 Re-Inspection · Deficiency Check · Internal Structural Exam · Cargo Tank Internal · Examination of Repairs · Hull Examination · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3434287
15 May 2008 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3207429
5 May 2008 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3199368
16 February 2007 Internal Structural Exam · Hull Examination · COI Inspection · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2873016
7 February 2007 Internal Structural Exam · Cargo Tank Internal · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2869796
4 May 2006 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2641463
14 February 2005 MTSA Verification · Re-Inspection · Examination of Repairs · Internal Structural Exam · Hull Examination · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2292048
2 July 2004 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2119036
21 June 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2105562
20 April 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2048243
6 March 2003 Administrative Inspection · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1750475
29 January 2002 Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1482343

Deficiency record · 29

09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 18 February 2025 Resolved
Nothing in this part shall limit the marine inspector to be assured the safety and seaworthiness of the vessel. Repair 03 vent pipe temp repairs on port & stbd sewage vent and 01 vent pipe for grey water.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2025
Resolved 24 February 2025
Resolution: Received photographs of repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 February 2025 Resolved
Each propulsion control system operable from the pilothouse must be able to shutdown each propulsion engine. Stbd propulsion engine could not be secured from the bridge.
Action required: 10 - Deficiency Rectified
Resolved 18 February 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 February 2025 Resolved
Each vessel that relies on electricity for loads mus tbe arranged so that loads can be energized from at least two sources of electricity. Starboard generator secured when fire pump was energized.
Action required: 10 - Deficiency Rectified
Resolved 18 February 2025
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 18 February 2025 Resolved
Each vessel must comply with 47 CFR part 80 as applicable. Vessels Single Side Band does not have DSC capabilities.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2025
Resolved 9 April 2025
Resolution: Received tech report of installation & fully operational.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 March 2024 Resolved
Standby vessels must have, at least, the following equipment: (12) A fire monitor with a minimum flow rate of, at least, 500 gallons per minute. Fire monitor inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2025
Resolved 25 February 2025
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 23 November 2021 Resolved
46 CFR 132.130(k) Must have a fire hose 50 ft in length with a 1 1/2 inch diameter, connected to an outlet for use at any time. Fire hose has two holes.
Action required: 10 - Deficiency Rectified
Resolved 29 November 2021
Resolution: Fire hose was replaced with a new one.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 4 May 2020 Resolved
Life float's weak link and painter installation improperly configured; correct such that life float's float free arrangements are IAW regs. 46 CFR 133.105(a)(4)(iii)(D)
Action required: 10 - Deficiency Rectified
Due 4 May 2020
Resolved 4 May 2020
Resolution: Master made the arrangement float-free.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 May 2020 Resolved
Flexible hose on starboard generator fuel service unservicable; must add chafing gear and replace with SAEJ 1942 approved type or equivalent. 46 CFR 56.60-25(b)
Action required: 10 - Deficiency Rectified
Due 4 May 2020
Resolved 4 May 2020
Resolution: Hoses satisfactorily replaced.
Engineering › Diesel Engine (auxiliary) › Turbocharger
Issued 11 January 2017 Resolved
forward thruser prime mover turbocharger exhaust missing lagging, leaving hot surfaces open to personnel.
Action required: 705 - Other - as specified
Due 18 January 2017
Resolved 11 January 2017
Resolution: Crew Properly wrapped exhaust elbow prior to the departure of attending marine inspectors.
Lifesaving › Lifebuoys › Stowage
Issued 11 January 2017 Resolved
Both aft Deck lifebuoys installed under stair platfroms. Platforms height made accessing the lifebouys difficult to reach
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 January 2017
Resolved 12 January 2017
Resolution: Both aft Deck lifebuoys properly reinstalled.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 20 April 2016 Resolved
Prove proper operation of rudder angle indicators at all locations.
Action required: 705 - Other - as specified
Due 21 April 2016
Resolved 21 April 2016
Resolution: Rudder angle indicator is operable at all locations.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 20 April 2016 Resolved
Provide adequate emergency lighting in port engine room.
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 21 April 2016
Resolution: Added battle lantern to port engine room to improve lighting.
Electrical › Electrical Distribution System (service) › Cable
Issued 12 May 2014 Resolved
New Cable runs for DP upgrade were found to not be properly supported every 24" IAW IEEE.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2014
Resolved 24 April 2015
Resolution: Verified all wiring was properly supported. Cleared prior 835.
Stability › Watertight Integrity › General
Issued 12 May 2014 Resolved
Water tight penetrations in aft engine room bulkhead for the hydraulic installation for the DP upgrade were dye pen tested and three leaks were found. Gouge, re-weld and retest to sat of attending Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2014
Resolved 14 May 2014
Resolution: Water tight penetrations were rewelded and tested.
Communications › Radio Communications › VHF Radiotelephone
Issued 18 January 2012 Resolved
Demonstrate proper operation of SSB on emergency power.
Action required: 705 - Other - as specified
Resolved 1 February 2012
Lifesaving › Lifebuoys › Serviceable
Issued 18 January 2012 Resolved
Replace ring lifebuoy on port side bride wing
Action required: 705 - Other - as specified
Resolved 1 February 2012
Electrical › Lighting (emergency) › Lighting Fixture
Issued 18 January 2012 Resolved
Replace battery of e-light facing e/r ladder
Action required: 705 - Other - as specified
Resolved 1 February 2012
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 January 2012 Resolved
Replace port nav light
Action required: 705 - Other - as specified
Resolved 1 February 2012
Lifesaving › Line-Throwing Appliances › Instructions/Diagrams
Issued 18 January 2012 Resolved
Provide instruction/diagrams for line-throwing appliance
Action required: 705 - Other - as specified
Resolved 1 February 2012
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 16 April 2009 Resolved
Demonstrate Proper Operation of of Stbd Generator Overspeed.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 April 2009
Resolved 16 April 2009
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 16 April 2009 Resolved
Provide and Implement Lifesaving Maintenance Record. To be checked next topside inspection.
Due 16 May 2009
Resolved 29 July 2010
Stability › Watertight Integrity › General
Issued 16 March 2009 Resolved
Demonstrate Proper operation of Engine Room Escape Hatch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2009
Construction/Loadline › Penetrations › Gasket
Issued 16 February 2007 Resolved
INSTALL HARD GASKET ON MAIN DECK GALLEY DOOR.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 February 2007
Resolved 16 February 2007
Resolution: COMPLETED
Documentation › Certificates/Documents › Stability Letter
Issued 16 February 2007 Resolved
CORRECT STABILITY LETTER WITH ABS LOADLINE CERTIFICATE.
Action required: 705 - Other - as specified
Due 16 February 2007
Resolved 16 February 2007
Resolution: COMPLETED
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 16 February 2007 Resolved
CORRECT SHAFT INDICATORS, WIRES ARE CROSSED AND READING BACKWARDS.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 February 2007
Resolved 16 February 2007
Resolution: COMPLETED
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 16 February 2007 Resolved
LOG AND INSPECT MONTHLY RESCUE HARNESS.
Action required: 705 - Other - as specified
Due 16 February 2007
Resolved 16 February 2007
Resolution: COMPLETED
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 16 February 2007 Resolved
PAINT SIDE LIGHTS MATTE BLACK.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 February 2007
Resolved 16 February 2007
Resolution: COMPLETED
Pollution Prevention/Response › Prevention Equipment › Internal Cargo Transfer Capability
Issued 16 February 2007 Resolved
INSTALL CAPS ON GEAR/LUBE OIL DRAIN VALVES IN ENGINE ROOM.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 February 2007
Resolved 16 February 2007
Resolution: COMPLETED
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 6 March 2003 Resolved
Install shaft speed and direction indicators IAW 46 CFR 113.37-5(a) LEGACY COMPONENT DESC: Propeller Speed Indicator
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2003
Resolved 20 April 2004

Ownership record