MAURY USCG vessel records Sign in
← All vessels

BARRINGTON ISLAND

BARRINGTON ISLAND is a 1993 freight ship. The Coast Guard has recorded 35 inspections since 1993, most recently in December 2017, along with 20 deficiencies and 6 operational controls.

Records from 1993 to 2017. Most recent: inspection, 17 December 2017.

Built
1993
Last inspected
17 December 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9059614 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
394190
Flag
BELIZE
—
Maury page id
psix-394190

Inspections, by type

…with no type recorded22
Years with a record 19 calendar years (1993–2017)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it14061 - Convention (Subpart B), Gross Ton
6900 - Convention (Subpart B), Net Ton
22560 - Displacement, Ton
14140 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 35

17 December 2017 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6322766
13 December 2017 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6323541
23 June 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4352999
20 May 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4316304
15 December 2011 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4208609
16 September 2011 PII Safety Exam · ISPS II Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4147025
3 January 2011 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3919005
3 September 2010 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3840996
29 August 2008 PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3312200
6 June 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3231859
4 June 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3227042
26 July 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3007620
22 June 2007 PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2970004
12 January 2006 MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2565464
28 July 2005 Random ISPS/MTSA/PSC
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2443169
12 January 2005 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2273585
28 December 2004 Random ISPS/MTSA/PSC · NPV Safety Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2265445
10 December 2004 Random ISPS/MTSA/PSC
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2257034
6 July 2004 ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2122989
12 May 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2072337
14 January 2004 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1984252
26 May 2003 Type not recorded
No type recorded · USCGC VIGOROUS (WMEC 627) · Activity 1806386
19 August 2002 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1663716
25 July 2002 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1651741
18 September 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1073634
24 July 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 292150
8 August 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 280784
5 August 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 431431
12 February 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 400413
1 June 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 391804
29 February 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 388792
5 October 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 383563
9 December 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 373464
3 November 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 362046
13 October 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 361448

Deficiency record · 20

Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 18 September 2011 Resolved
The necessary pipes for conveying fire-extinguishing medium into protected spaces shall be provided with control valves so marked as to indicate clearly the spaces to which the pipes are led. A contradiciton exists between the CO2 control valves for cargo hold marking system, and the posted intstructions for discharging CO2. Deficiency to be cleared by class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 September 2011
Resolution: Class report dated 28 Sep 2011, attests to proper instructions made for fixed CO2 system.
Construction/Loadline › Structures › Door
Issued 18 September 2011 Resolved
SOLAS 74 (95 Amend.) II-1/1.3.1 All ships which undergo repairs, alterations, modification and outfitted reated thereto shall continue to comply with at least the requiremements previoiusly applicable to these ships. There is a bent door sill in the forward compartment which leads to the emergency fire pump. Deficiency to be cleared by class.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 September 2011
Resolution: Class report dated 28 Sep 2011 attests to proper repairs made to bent sill.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 3 September 2010 Resolved
STCW ANNEX I/2.6.3: Endorsements shall be assigned a unique number, except that endorsements attesting the issue of a certifcate shall expire as soon as the certificate endorsed expires or is withdrawn. Vessel third engineer is lacking a proper endorsement of his 2nd class engineering national licence.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 September 2010
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 January 2006 Resolved
Three guard rails on the weather deck have been broken and need to be rewelded back in place. Make repairs to satisfaction of the classification society.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 January 2006
Resolved 13 January 2006
Resolution: Broken railings have been cropped an renewed.
Engineering › Lubricating Oil Storage/Transfer System › Tank
Issued 12 January 2006 Resolved
There appears to be a doubler patch repair on the lube oil storage tank just fwd of the steering space fwd of frame 4, on deck 4. Provide a report of acceptance of the repair by the classification society.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 January 2006
Resolved 13 January 2006
Resolution: Memoranda imposed by LR to have doubler inspected at next dry dock. LR report MMI 640011.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 12 January 2006 Resolved
Galley Zone "A" self closing doors from galley to crew mess and galley to officers mess have been equipped with hold back devices. Remove devices prior to the departure of the Coast Guard inspector.
Action required: 705 - Other - as specified
Due 12 January 2006
Resolved 12 January 2006
Resolution: Corrected on the spot.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 12 January 2006 Resolved
Fire Control Protection and Detection Safety Plan legend shows Zone "A" boundaries to be in yellow and Zone"B" boundaries to be in red. Plan shows Zone "A" in red and Zone "B" in yellow . Have classification society review all plans for accuracy and make changes if needed.
Action required: 705 - Other - as specified
Due 12 February 2006
Resolved 13 January 2006
Resolution: Legends on non-plasticized plans were corrected. Memorandum imposed on revisions to remaining plans. LR report MMI 640011.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 12 January 2006 Resolved
Stern launch lifeboat engine failed to start. Make necessary repairs to the satisfaction of the classification society prior to departure. Class provided report stating that engine could not be fixed prior to sailing and boat would be replaced in Antwerp, Belgium. Lloyds Register report MMI 640011 dated 13 Jan 06. CSSE withdrawn and conditional placed on board the vessel.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 March 2006
Resolution: Lifeboat replaced in Antwerp, Belgium on 23Jan06, as per LR Interim CSSE dated 24Jan06.
Navigation › Piloting/Steering › Gyro Compass
Issued 12 January 2005 Resolved
Inoperable Gyrocompass.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2005
Resolution: Cleared based on fax report from Sperry Marine stating repairs have been completed.
Navigation › Piloting/Steering
Issued 12 May 2004 Resolved
Vessel wishes to enter the Port of New York with an inop gyro compass, vessel has arranged to effect repairs prior to departing the Port of New York. LEGACY COMPONENT DESC: Gyro Compass
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2004
Resolution: Vessel has faxed a Tech report to this unit satisfing this LOD requirements.
Accommodation/Occupational Safety
Issued 24 July 2001 Resolved
Valve #31-652 F/O service to ships boiler must remain closed $ system placed out of service until permanent repairs are made to F/O leak in aux ER to the satisfaction of attending class surveyor. Permanent repairs must be made $ Class report received by local CG office no later than 07AUG01.
Condition: Unknown
Due 7 August 2001
Resolved 7 August 2001
Fire Fighting
Issued 24 July 2001 Resolved
Vessel must not depart Port of New York until installed co2 system is serviced,damaged flexible loops are determined to be fit for continued use & a Satisfactory report is received by Captain of the Port of [name withheld] attesting to proper operation of this system.
Condition: Unknown
Due 24 July 2001
Resolved 27 July 2001
Lifesaving
Issued 5 August 1999 Resolved
free-fall launch the vessels life boat and log same. Prior to the vessels next port of call.
Condition: Unknown
Due 14 January 2000
Resolved 14 January 2000
Electrical
Issued 29 February 1996 Resolved
Provide electrical matting in way of switchboards in emergency generator room.
Condition: Unknown
Due 1 June 1996
Resolved 1 June 1996
Engineering
Issued 29 February 1996 Resolved
At next US port, demonstrate proper operation of oil-water separator in thepresence of CG inspector.
Condition: Unknown
Due 10 March 1996
Resolved 13 March 1996
Engineering
Issued 29 February 1996 Resolved
Have Lloyds Surveyor board vessel and prove proper operation of oil-water separator; provide this report to CG.
Condition: Unknown
Due 9 March 1996
Resolved 9 March 1996
Lifesaving
Issued 29 February 1996 Resolved
Update SOLAS training manual, deleting items from the manual that do not apply to this particular vessel. Updated manual should not include passages describing types of lifeboats not actually on vessel; manual should not describe LB procedures in a general way-specific to vessel only.
Condition: Unknown
Due 1 June 1996
Resolved 1 June 1996
Lifesaving
Issued 29 February 1996 Resolved
Repair or replace damaged liferaft canister for forward six person liferaft.
Condition: Unknown
Due 1 June 1996
Resolved 1 June 1996
Navigation
Issued 13 October 1993 Resolved
COASTPILOT NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 3 November 1993
Resolved 3 November 1993
Navigation
Issued 13 October 1993 Resolved
CHARTS 12326,12327,12333,12334 NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 3 November 1993
Resolved 3 November 1993

Ownership record