MAURY USCG vessel records Sign in
← All vessels

SENATOR

SENATOR is a 1993 freight ship. The Coast Guard has recorded 20 inspections since 1993, most recently in September 2004, along with 14 deficiencies.

Records from 1993 to 2004. Most recent: inspection, 1 September 2004.

Built
1993
Last inspected
1 September 2004
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9052329 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
394260
Flag
BAHAMAS, THE
—
Maury page id
psix-394260

Inspections, by type

…with no type recorded15
Years with a record 11 calendar years (1993–2004)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it15884 - Convention (Subpart B), Gross Ton
15884 - Regulatory (Subpart C or D), Gross Ton
8992 - Convention (Subpart B), Net Ton
8992 - Regulatory (Subpart C or D), Net Ton
26456 - Dead Weight, Ton
32206 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 20

1 September 2004 NPV Safety Exam · ISPS II Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2183549
4 June 2003 MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1809914
30 December 2002 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1724335
23 August 2002 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1665326
7 August 2002 Ballast Water Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1656401
10 August 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 292515
4 March 2000 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 275414
22 February 2000 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 475835
14 February 2000 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 274855
15 January 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 424584
30 May 1997 Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 404224
29 June 1996 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 392699
3 February 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 387432
3 February 1996 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 392251
24 March 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 376367
8 February 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 374957
20 October 1994 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 371294
20 May 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 649787
19 May 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 366939
7 September 1993 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 360647

Deficiency record · 14

Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 4 June 2003 Resolved
Provide Class report verifying proper operation of the Oily-Water Separating equpment and the incinerator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2003
Resolution: Recieved class report.
Documentation › Logs/Records
Issued 7 August 2002 Resolved
Commence making entries into the oil record book as per the instructions found in appendix III of annex I of marpol 73/78. Where the entries listed under C-12.2 and C-12.3 are missing the soundings LEGACY COMPONENT DESC: Oil Record Book
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2002
Resolved 23 August 2002
Resolution: Entries in oil record book were corrected.
Pollution Prevention/Response › Prevention Equipment
Issued 7 August 2002 Resolved
Repair and prove proper operation of the oily water seperator where the oil solenoid has overheated from remaining in the open position for extended periods of time. As per Marpol 73/78 I/16. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 August 2002
Resolved 23 August 2002
Resolution: Received class survey and they consider USCG deficiency to now be rectified.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 7 August 2002 Resolved
Make the fire doors self closing. As per SOLAS 74 ammended II-2/47. LEGACY COMPONENT DESC: fire doors
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 September 2002
Resolved 1 September 2004
Resolution: RESOLVED DURING PREVIOUS PSC EXAM
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 7 August 2002 Resolved
Provide proper chlorine tablets for proper operation of the MSD. As per SOLAS 74 ammended I/II and 33 C.F.R. 159.7.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2002
Resolved 7 August 2002
Resolution: Recieved fax from agent showing purchase of chlorine tablets for the MSD.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 7 August 2002 Resolved
Update the fire control plan. As per SOLAS 74 Ammended II-2/20 LEGACY COMPONENT DESC: Fire Control Plans
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 September 2002
Resolved 1 September 2004
Resolution: RESOLVED DURING PREVIOUS PSC EXAM
Electrical
Issued 14 February 2000 Resolved
Renew/replace damaged electrical wires and light fixtures in the laundry room that sustained damage during fire. Correct to satisfaction of class and provide nearest MSO with class report._x001C_
Condition: Unknown
Due 28 August 2001
Resolved 28 August 2001
Navigation
Issued 14 February 2000 Resolved
Provide/repair lighted magnetic compass on bridge prior to departure. Fax MSO San Juan statement from master attesting to repair prior to departure._x001C_
Condition: Unknown
Due 4 March 2000
Resolved 4 March 2000
Electrical
Issued 3 February 1996 Resolved
Remove the paint from the NO. 5 Deck Store being used as an additional paint locker, or provide explosion proof lighting for the compartment._x001C_ _x001C_ Solas Ch II-1, Reg 45
Condition: Unknown
Due 3 July 1996
Resolved 3 July 1996
Lifesaving
Issued 3 February 1996 Resolved
Remove the coil of lashing wire obstructing the egress pathway from the bridge deck entrance on the 2nd deck aft (next to the NO. 5 paint locker), prior to the next U.S. port call._x001C_ Solas Ch II-2, Reg 45
Condition: Unknown
Due 3 July 1996
Resolved 3 July 1996
Fire Fighting
Issued 3 February 1996 Resolved
Correct the leakage at the fire main expansion joint located at the #4 cargo hold, starboard side, prior to the next U.S. port call._x001C_ _x001C_ Solas Ch. II-2, Reg 4
Condition: Unknown
Due 3 July 1996
Resolved 3 July 1996
Lifesaving
Issued 8 February 1995 Resolved
Mount forward six man liferaft on the weather deck (forward), prior to departure, per Solas Chpt. III Reg 26(1.4).
Condition: Unknown
Due 11 February 1995
Resolved 10 February 1995
Navigation
Issued 19 May 1994 Resolved
Charts not corrected since 26/93.
Condition: Unknown
Due 30 March 1995
Resolved 30 March 1995
Navigation
Issued 19 May 1994 Resolved
1993 LIGHT LIST NOT CORRECTED.
Condition: Unknown
Due 30 March 1995
Resolved 30 March 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.