Records from 1993 to 2004. Most recent: inspection, 1 September 2004.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 20
1 September 2004
NPV Safety Exam · ISPS II Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2183549
4 June 2003
MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1809914
30 December 2002
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1724335
23 August 2002
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1665326
7 August 2002
Ballast Water Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1656401
10 August 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 292515
4 March 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 275414
22 February 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 475835
14 February 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 274855
15 January 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 424584
30 May 1997
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 404224
29 June 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 392699
3 February 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 387432
3 February 1996
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 392251
24 March 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 376367
8 February 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 374957
20 October 1994
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 371294
20 May 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 649787
19 May 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 366939
7 September 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 360647
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 4 June 2003
Resolved
Provide Class report verifying proper operation of the Oily-Water Separating equpment and the incinerator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2003
Resolution: Recieved class report.
Documentation › Logs/Records
Issued 7 August 2002
Resolved
Commence making entries into the oil record book as per the instructions found in appendix III of annex I of marpol 73/78. Where the entries listed under C-12.2 and C-12.3 are missing the soundings LEGACY COMPONENT DESC: Oil Record Book
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2002
Resolved 23 August 2002
Resolution: Entries in oil record book were corrected.
Pollution Prevention/Response › Prevention Equipment
Issued 7 August 2002
Resolved
Repair and prove proper operation of the oily water seperator where the oil solenoid has overheated from remaining in the open position for extended periods of time. As per Marpol 73/78 I/16. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 August 2002
Resolved 23 August 2002
Resolution: Received class survey and they consider USCG deficiency to now be rectified.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 7 August 2002
Resolved
Make the fire doors self closing. As per SOLAS 74 ammended II-2/47. LEGACY COMPONENT DESC: fire doors
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 September 2002
Resolved 1 September 2004
Resolution: RESOLVED DURING PREVIOUS PSC EXAM
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 7 August 2002
Resolved
Provide proper chlorine tablets for proper operation of the MSD. As per SOLAS 74 ammended I/II and 33 C.F.R. 159.7.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2002
Resolved 7 August 2002
Resolution: Recieved fax from agent showing purchase of chlorine tablets for the MSD.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 7 August 2002
Resolved
Update the fire control plan. As per SOLAS 74 Ammended II-2/20 LEGACY COMPONENT DESC: Fire Control Plans
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 September 2002
Resolved 1 September 2004
Resolution: RESOLVED DURING PREVIOUS PSC EXAM
Electrical
Issued 14 February 2000
Resolved
Renew/replace damaged electrical wires and light fixtures in the laundry room that sustained damage during fire. Correct to satisfaction of class and provide nearest MSO with class report._x001C_
Condition: Unknown
Due 28 August 2001
Resolved 28 August 2001
Navigation
Issued 14 February 2000
Resolved
Provide/repair lighted magnetic compass on bridge prior to departure. Fax MSO San Juan statement from master attesting to repair prior to departure._x001C_
Condition: Unknown
Due 4 March 2000
Resolved 4 March 2000
Electrical
Issued 3 February 1996
Resolved
Remove the paint from the NO. 5 Deck Store being used as an additional paint locker, or provide explosion proof lighting for the compartment._x001C_ _x001C_ Solas Ch II-1, Reg 45
Condition: Unknown
Due 3 July 1996
Resolved 3 July 1996
Lifesaving
Issued 3 February 1996
Resolved
Remove the coil of lashing wire obstructing the egress pathway from the bridge deck entrance on the 2nd deck aft (next to the NO. 5 paint locker), prior to the next U.S. port call._x001C_ Solas Ch II-2, Reg 45
Condition: Unknown
Due 3 July 1996
Resolved 3 July 1996
Fire Fighting
Issued 3 February 1996
Resolved
Correct the leakage at the fire main expansion joint located at the #4 cargo hold, starboard side, prior to the next U.S. port call._x001C_ _x001C_ Solas Ch. II-2, Reg 4
Condition: Unknown
Due 3 July 1996
Resolved 3 July 1996
Lifesaving
Issued 8 February 1995
Resolved
Mount forward six man liferaft on the weather deck (forward), prior to departure, per Solas Chpt. III Reg 26(1.4).
Condition: Unknown
Due 11 February 1995
Resolved 10 February 1995
Navigation
Issued 19 May 1994
Resolved
Charts not corrected since 26/93.
Condition: Unknown
Due 30 March 1995
Resolved 30 March 1995
Navigation
Issued 19 May 1994
Resolved
1993 LIGHT LIST NOT CORRECTED.
Condition: Unknown
Due 30 March 1995
Resolved 30 March 1995