Records from 1993 to 2011. Most recent: inspection, 16 February 2011.
Inspection history · 40
16 February 2011
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3945610
10 February 2011
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3939815
1 February 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3673803
29 January 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3672418
24 January 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3669096
13 February 2007
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2871343
6 January 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2562003
3 July 2005
MARPOL Annex I Examination · COC-TVE Annual · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2409399
8 July 2004
COC-TVE Renew · ISPS II Exam
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2119698
8 July 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2126397
16 April 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2045415
15 April 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2044657
5 April 2004
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2037995
6 December 2003
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1960683
27 August 2003
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1896476
5 July 2002
Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1640784
18 April 2002
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1606315
17 June 2001
Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1065434
14 June 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 291001
31 May 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 278289
31 May 2000
Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1050763
5 June 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 428862
5 June 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 809226
11 June 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 416907
7 January 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 654355
22 December 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 49806
10 December 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 410695
8 December 1997
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 437878
9 July 1997
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 405475
8 July 1997
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 406438
8 July 1997
Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 780941
12 August 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 381610
17 March 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 376507
26 August 1994
Tank Vessel Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1175818
18 June 1994
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1183119
4 April 1994
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1166547
8 March 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 365056
27 January 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 647319
20 January 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 363831
24 September 1993
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1132721
Fire Fighting › Remote Fuel Shutoff › General
Issued 16 February 2011
Resolved
0750-Fire Prevention-Oil pipes shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside space concerned. PSCO discovered closing mechanism on the #1&2 starboard deep tank remote shut off valves holding the valves in the closed position. Provide clarification from class attesting to the valve's ability to operate properly. SOLAS 74a II-2/4
Action required: 705 - Other - as specified
Due 23 February 2011
Resolved 16 June 2011
Resolution: Recieved Class report attesting to proper operation of quick closing valves.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 16 February 2011
Resolved
0899-Each loading arm and each transfer pipe system, including each metallic hose, must not leak under static liquid pressure at least 1 1/2 times the max allowable working pressure. Master could not provide documentation attesting to piping system being tested IAW US regulations. 33 CFR 155.170
Action required: 703 - Prior to bunkering operations
Due 16 February 2011
Resolved 16 June 2011
Resolution: Recieved confirmation for bunker line test.
Navigation › Collision/Grounding Avoidance › Radar
Issued 30 June 2005
Resolved
Secondary radar inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2005
Resolution: Received tech report via fax confirming repairs were made to the secondary radar.
Navigation › Collision/Grounding Avoidance › Radar
Issued 18 April 2002
Resolved
Radar - Unknown Cause/Condition
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 April 2002
Resolution: Recieved class report stating components burned on transceiver power supply-replaced power supply, set + mod for 500 VDC, magnetron heat for 6.3 VDC -retuned radar tested with sat results
Construction/Loadline
Issued 8 July 1997
Resolved
HAVE A MARINE CHEMIST CERTIFY THE PUMPROOM GAS FREE AND MAKE THE CONDITION OF THE PUMPROOM SATISFACTORY TO THE ATTENDING MARINE INSPECTOR, AT NEXT U.S. PORT CALL.
Condition: Unknown
Due 10 December 1997
Resolved 10 December 1997
Navigation
Issued 20 January 1994
Resolved
MSO TAMPA PERSONNEL WHILE CONDUCTING AN ANNUAL EXAMINTATION NOTED THAT THE SHIPS COAST PILOT (BA 1992 EDITION) WAS NOT UPDATED PAST THE 1992 EDITION PRINTING._x001C_ _x001C_
Condition: Unknown
Due 21 January 1994
Resolved 27 January 1994
Deck/Cargo
Issued 24 September 1993
Resolved
STENCIL (MARK) 95% HIGH LEVEL AND 98% OVERFILL ALARMS.
Condition: Unknown
Due 24 September 1993
Resolved 24 September 1993