Records from 1993 to 2023. Most recent: inspection, 12 June 2023.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 41
12 June 2023
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7713258
31 October 2022
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7586835
4 October 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7575183
2 June 2022
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7465504
16 November 2021
DAPI Audit · COI Inspection · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7351015
16 February 2021
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7138477
1 June 2020
Internal Structural Exam · Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6965277
20 February 2020
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6911534
12 February 2019
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6623788
14 May 2018
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6412033
15 February 2018
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6355249
21 November 2016
Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6025801
11 May 2016
Annual Inspection · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5878613
7 October 2015
Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5720251
20 June 2012
Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4349884
14 September 2011
Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4143144
13 October 2010
DAPI Audit · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3864802
4 November 2008
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3356617
21 August 2008
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3270327
14 September 2006
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2777531
21 August 2006
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2753209
27 February 2006
Simplified Stability Test
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2592786
19 October 2005
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2517414
16 May 2005
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2032075
17 November 2004
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2242770
19 October 2004
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2223986
30 August 2004
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2181059
10 September 2003
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1900960
30 August 2002
Hull Examination · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1668682
3 October 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1074330
13 September 2001
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1397725
8 September 2000
Examination of Repairs · Hull Examination · Deficiency Check · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1376327
3 September 1999
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1473245
8 September 1998
Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1468023
4 September 1997
Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1394858
9 September 1996
COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1360669
28 September 1995
Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1182979
12 September 1994
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 867898
15 October 1993
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1158574
28 September 1993
Hull Examination · Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 846608
1 September 1993
Initial Construction-Excluding Oversight
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1138793
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 June 2023
No resolution recorded
Vessel is overdue for annual inspection. Vessel must undergo satisfactory inspection by a USCG marine inspector prior to returning to service.
Action required: 60 - Rectify deficiencies prior to movement
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 October 2022
No resolution recorded
Vessel was identified as having potential damage from Hurricane IAN. Prior to conducting repairs, contact the local USCG Marine Inspections office and submit a repair proposal for approval. Vessel is not permitted to return to commercial service until cleared by a USCG Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 February 2021
Resolved
Provide proper ring buoy light that meets 46 CFR 161.010 and properly secure to buoy witha corrosion resistant clip.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2021
Resolved 3 March 2021
Resolution: Received photo of new light for ring buoy.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 February 2021
Resolved
The starboard navigation light lens is blue in color due to deterioration - replace with green.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2021
Resolved 3 March 2021
Resolution: Received photo of new green starboard light.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 16 February 2021
Resolved
Alcohol testing swabs are expired. Provide new swabs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2021
Resolved 3 March 2021
Resolution: Received photo of new alcohol swabs onboard.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 February 2018
Resolved
Floating waterlight is inoperable.
Action required: 705 - Other - as specified
Resolved 6 March 2018
Resolution: Light repaired.
Documentation › Markings/Placards › Lifejacket Placard
Issued 15 February 2018
Resolved
Post lifejacket donning placard.
Due 1 March 2018
Resolved 6 March 2018
Resolution: Donning placared posted.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 15 February 2018
Resolved
Provide EAP policy statement, substance abuse professional contact, and hotline number.
Action required: 705 - Other - as specified
Due 1 March 2018
Resolved 6 March 2018
Resolution: On board and posted.
Navigation › Piloting/Steering › Marine Charts
Issued 15 February 2018
Resolved
Provide updated charts, publications.
Action required: 705 - Other - as specified
Due 1 March 2018
Resolved 6 March 2018
Resolution: Purchased, on board.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 15 February 2018
Resolved
Indicate number of child and adult lifejackets in way of stowage locations.
Action required: 705 - Other - as specified
Due 1 March 2018
Resolved 6 March 2018
Resolution: Correct number indicated at stowage locations.
Construction/Loadline › Structures › Deck Plating
Issued 11 May 2016
Resolved
Scrape away all decayed would on the underside of the deck between the pontoon's amidships.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 May 2016
Resolved 14 May 2016
Resolution: Area scraped back to good wood and preserved.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 14 September 2011
Resolved
Provide an MIS report for drug testing IAW 46 CFR 16.
Action required: 705 - Other - as specified
Due 21 September 2011
Resolved 19 September 2011
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 September 2011
Resolved
Repair port nav light for proper illumination IAW 46 CFR 183.420.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2011
Documentation › Markings/Placards › Garbage Placard
Issued 14 September 2011
Resolved
Provide on board a garbage placard IAW 46 CFR 184.702.
Action required: 705 - Other - as specified
Due 21 September 2011
Resolved 19 September 2011
Operations/Management › Drills/Instruction › Not Conducted
Issued 14 September 2011
Resolved
Provide a training log for crew drills IAW 46 CFR 185.420(c).
Action required: 705 - Other - as specified
Due 21 September 2011
Resolved 19 September 2011
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 13 October 2010
Resolved
Provide current contract with drug consortium.
Action required: 705 - Other - as specified
Resolved 21 October 2010
Lifesaving › Hand Flares › Quantity
Issued 13 October 2010
Resolved
Provide 01 additional red hand flare.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2010
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 13 October 2010
Resolved
Provide 14 adult and 01 child lifejackets to total 22 adult and 03 child lifejackets. The vessel may operate with six passengers as required by the COI.
Action required: 705 - Other - as specified
Resolved 18 October 2010
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 19 October 2004
Resolved
Provide all employees are covered under one consortium.
Action required: 705 - Other - as specified
Due 19 November 2004
Resolved 17 November 2004
Resolution: RCVD FROM APCA
Navigation
Issued 13 September 2001
Resolved
PROVIDE NAV LIGHT SHOWING FORWARD AS PER NAV RULE 23.
Condition: Unknown
Due 13 September 2001
Resolved 13 September 2001
Lifesaving
Issued 13 September 2001
Resolved
PROVIDE WATERLIGHT THAT FLOATS UPRIGHT FOR LIFE RING. _x001C_ VESSEL RESTRICTED TO DAYLIGHT OPERATIONS UNTIL CORRECTED.
Condition: Unknown
Due 13 September 2001
Resolved 13 September 2001
Lifesaving
Issued 13 September 2001
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 13 September 2001
Resolved 13 September 2001
Construction/Loadline
Issued 8 September 2000
Resolved
CONDUCT REPAIRS WERE DELAMINATION OF WOOD DECKING OCCURING.
Condition: Unknown
Due 23 October 2000
Resolved 23 October 2000
Engineering
Issued 3 September 1999
Resolved
PROVIDE SECOND MEANS OF CONTROL FOR PROPULSION MACHINERY AND STEERING SYSTEM. DEMONSTRATE OPERATION TO ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Fire Fighting
Issued 9 September 1996
Resolved
PROVIDE 3 FIRE BUCKETS WITH LANYARDS ATTACHED, LABEL EACH "FIRE BUCKET."_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 September 1996
Resolved 20 November 1996
Lifesaving
Issued 9 September 1996
Resolved
PAINT FLARE BOX BRIGHT COLOR, LABEL ""DISTRESS SIGNALS."_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 September 1996
Resolved 20 November 1996
Lifesaving
Issued 9 September 1996
Resolved
REPAIR RING BUOY WATERLIGHT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 September 1996
Resolved 20 November 1996
Fire Fighting
Issued 9 September 1996
Resolved
PRIOR TO CARRYING PASSENGERS, SERVICE ALL FIRE EXTINGUISHERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 September 1996
Resolved 20 November 1996
Lifesaving
Issued 28 September 1993
Resolved
Stencil name of vessel on hull P & S sides, ringbuoy and all pfd's.
Condition: Unknown
Due 28 September 1993
Resolved 28 September 1993
Documentation
Issued 28 September 1993
Resolved
Affix registration number to hull.
Condition: Unknown
Due 28 September 1993
Resolved 28 September 1993