MAURY USCG vessel records Sign in
← All vessels

MSC SUKAIYNA

MSC SUKAIYNA is a 1987 freight ship. The Coast Guard has recorded 20 inspections since 1993, most recently in June 2005, along with 8 deficiencies and 3 operational controls.

Records from 1993 to 2005. Most recent: operational control imposed, 13 June 2005.

Built
1987
Last inspected
13 June 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8310530 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
394280
Flag
PANAMA
—
Maury page id
psix-394280

Inspections, by type

…with no type recorded19
Years with a record 5 calendar years (1993–2005)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it22746 - Convention (Subpart B), Gross Ton
6823 - Convention (Subpart B), Net Ton
35007 - Displacement, Ton
24515 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

13 June 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2389879
7 March 2005 MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2302215
20 March 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 389208
25 September 1995 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 383052
22 June 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 380048
18 January 1995 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 374312
7 January 1995 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 373806
28 December 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 373618
26 October 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 371729
26 October 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 868742
24 October 1994 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1173721
22 October 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 493020
21 October 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 33080
21 October 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 677319
20 October 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 515376
1 October 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 370910
7 August 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 369166
16 February 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 364595
28 December 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 677320
26 December 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 363326

Deficiency record · 8

Lifesaving
Issued 25 September 1995 Resolved
The vessel's liferafts were inproperly rigged in that the seapainters were not attached to a weak link. solas III/6.1._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 September 1995
Resolved 10 October 1995
Lifesaving
Issued 25 September 1995 Resolved
The vessel's lifeboat motors were inoperable, and the batteries for the starting system were not properly mounted. solas III/19.2
Condition: Unknown
Due 26 September 1995
Resolved 10 October 1995
Construction/Loadline
Issued 25 September 1995 Resolved
Paking gland on 3 overboard discharge valves leaking. solas II-1/26
Condition: Unknown
Due 15 November 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 25 September 1995 Resolved
Batteries on the vessels emergency generator were not properly secured, room had additional batteries on deck._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 September 1995
Resolved 10 October 1995
Electrical
Issued 25 September 1995 Resolved
Electrical covers on controllers and distribution board missing. solas II- 1/40._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 September 1995
Resolved 10 October 1995
Documentation
Issued 22 June 1995 Resolved
VESSEL DID NOT HAVE A VALID SAFETY RADIO CERTIFICATE.
Condition: Unknown
Due 22 June 1995
Resolved 28 June 1995
Navigation
Issued 1 October 1994 Resolved
vessel had an inoperable primary marine radar system due to the failure of a capacitor while mooring. Vessel requiered to have 2 operable marine radar systems, unable to fix before departing. Vessel issue COTP order 83-94 to depart in daylight only.
Condition: Unknown
Due 21 October 1994
Resolved 21 October 1994
Documentation
Issued 26 December 1993 Resolved
CHIEF MATE STATED THAT THE OIL TRANSFER PROCEDURES WERE IN THE [name withheld] AND HE WAS UNABLE TO RETRIEVE THEM. CAPTIAN AND CHIEF ENGINEER WERE NOT ON BOARD.
Condition: Unknown
Due 16 February 1994
Resolved 16 February 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.