Records from 2016 to 2019. Most recent: inspection, 19 July 2019.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 27 February 2019
No resolution recorded
Conduct drills to satisfaction of attending CG marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 February 2019
No resolution recorded
Provide 3 fire buckets.
Action required: 60 - Rectify deficiencies prior to movement
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 27 February 2019
No resolution recorded
Provide current MARPOL V placard.
Action required: 60 - Rectify deficiencies prior to movement
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 February 2019
No resolution recorded
Properly label lifejacket storage with location and number of lifejackets.
Action required: 60 - Rectify deficiencies prior to movement
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 February 2019
No resolution recorded
Separate children's lifejackets from adults.
Action required: 60 - Rectify deficiencies prior to movement
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 February 2019
No resolution recorded
Provide retro reflective tape on ring buoy.
Action required: 60 - Rectify deficiencies prior to movement
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 February 2019
No resolution recorded
Provide 60' floating life line for ring buoy.
Action required: 60 - Rectify deficiencies prior to movement
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 February 2019
No resolution recorded
Provide tether for ring buoy light 3-6' in length with corrosion resistant clip.
Action required: 60 - Rectify deficiencies prior to movement
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 27 February 2019
No resolution recorded
Permanently mount EPIRB in float free arrangement.
Action required: 60 - Rectify deficiencies prior to movement
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 27 February 2019
No resolution recorded
Provide current EPIRB registration.
Action required: 60 - Rectify deficiencies prior to movement
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 February 2019
No resolution recorded
Provide current first aid kit.
Action required: 60 - Rectify deficiencies prior to movement
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 February 2019
No resolution recorded
Provide FCC radio station license.
Action required: 60 - Rectify deficiencies prior to movement
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 February 2019
No resolution recorded
Provide FCC radio safety telephony certificate.
Action required: 60 - Rectify deficiencies prior to movement
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 February 2019
No resolution recorded
Provide FCC operators license.
Action required: 60 - Rectify deficiencies prior to movement
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 27 February 2019
No resolution recorded
Repair or replace light fixture in fwd compartment and overhead operating station.
Action required: 60 - Rectify deficiencies prior to movement
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 February 2019
No resolution recorded
Provide sound producing device.
Action required: 60 - Rectify deficiencies prior to movement
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 27 February 2019
No resolution recorded
Provide Drug and Alcohol testing program.
Action required: 60 - Rectify deficiencies prior to movement
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 February 2019
No resolution recorded
Provide a 10-BC fire extinguisher for main cabin at
machinery space entrance.
Action required: 60 - Rectify deficiencies prior to movement
Engineering › Bilge Water Management System › Pump
Issued 13 January 2017
Resolved
Prove proper operation of engine room bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 January 2017
Resolution: Proper operation of bilge system witnessed.
Engineering › Fuel Oil Service System › Piping
Issued 13 January 2017
Resolved
Provide hose clamp on starboard fuel tank fill pipe.
Action required: 705 - Other - as specified
Due 27 January 2017
Resolved 14 January 2017
Resolution: Hose clamps installed.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 13 January 2017
Resolved
Post emergency instructions.
Action required: 705 - Other - as specified
Due 27 January 2017
Resolved 14 January 2017
Resolution: Emergency instructions posted.
Lifesaving › Lifebuoys › Serviceable
Issued 13 January 2017
Resolved
Provide new ring buoy.
Action required: 705 - Other - as specified
Due 27 January 2017
Resolved 14 January 2017
Resolution: New ring buoy installed.
Lifesaving › Lifefloat › Serviceable
Issued 7 January 2016
Resolved
Replace life float. Life float found to be in unsatisfactory conditon.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 January 2016
Resolved 12 January 2016
Resolution: Life float replaced.
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 7 January 2016
Resolved
Replace shift and throttle cables.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 January 2016
Resolved 11 January 2016
Resolution: Cables replaced with new cables.
Electrical › Electrical Distribution System (service) › Cable
Issued 7 January 2016
Resolved
Clean and secure battery cable terminals.
Action required: 705 - Other - as specified
Due 21 January 2016
Resolved 11 January 2016
Resolution: Wire lugs and attachments cleaned up and tightened.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 January 2016
Resolved
Remove dead end wires in engine room.
Action required: 705 - Other - as specified
Due 21 January 2016
Resolved 11 January 2016
Resolution: Dead end wires removed.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 7 January 2016
Resolved
Provide written procedures for emergency steering on emergency instructions.
Action required: 705 - Other - as specified
Due 21 January 2016
Resolved 1 February 2016
Resolution: Emergency steering instructions on board.
Construction/Loadline › Structures › Manhole
Issued 7 January 2016
Resolved
Provide lanyard/chain for lazarette cover.
Action required: 705 - Other - as specified
Due 21 January 2016
Resolved 11 January 2016
Resolution: Hatch cover secured with lanyard.
Fire Fighting › Fire Bucket › Availability
Issued 7 January 2016
Resolved
Provide 3 2.5 gallon fire buckets.
Action required: 705 - Other - as specified
Due 21 January 2016
Resolved 11 January 2016
Resolution: Fire buckets installed.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 7 January 2016
Resolved
Provide fire screen for fuel vents.
Action required: 705 - Other - as specified
Due 21 January 2016
Resolved 1 February 2016
Resolution: Fire screen installed.