Records from 2006 to 2026. Most recent: inspection, 6 March 2026.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 6 March 2026
Resolved
Whenever damage to hull or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space. Vessel reported impacting a submerged vessel while transiting near Fleming Key at 2-3 knots. Vessel shall be made available for inspection prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 January 2025
Resolved
Approx 24" of the electrical cable running to the starboard engine room Fireboy is secured along a fuel line. Route electrical cable away from fuel line.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 January 2025
Resolved
Install a cover on the starboard engine room battery box or other such means to protect the batteries from falling objects.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2025
Resolved 6 February 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 23 January 2025
Resolved
Provide a weathertight hatch covering the main starboard hull access opening.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2025
Resolved 6 February 2025
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 23 January 2025
Resolved
Install guards over the rotating machinery on the port engine (small belt drive to fire pump pto).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2025
Resolved 6 February 2025
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 23 January 2025
Resolved
Provide a visual indicator for the port bilge high level alarm (audible alarm is functioning).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2025
Resolved 6 February 2025
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 23 January 2025
Resolved
Provide a public address system of battery powered bullhorn.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2025
Resolved 6 February 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 January 2025
Resolved
Received report that the pre-engineered fixed fire extinguishing system accidentally discharged during engine room maintenance. Replace cylinder and test system prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 January 2024
Resolved
Sand back and fill in small FRP gouge on the mainmast base, starboard side.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 February 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 January 2024
Resolved
Mark the vessel's name on the ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 February 2024
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 November 2022
Resolved
The starboard power driven fire pump was leaking at the pump seals. Adequate pressure was obtained, but pump shall be replaced or new seals installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 November 2022
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 19 January 2022
Resolved
Change vessel's EPIRB registration to the Unit Identification Number (UIN) of the EPIRB installed on board.
Action required: 10 - Deficiency Rectified
Resolved 19 January 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 January 2022
Resolved
Provide 4 additional (7 total) child-size life jackets. Vessel restricted to adults only until all child-size life jackets are on board.
Action required: 705 - Other - as specified
Resolved 21 January 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 October 2020
Resolved
Replace the ring life buoy. 46 CFR 180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 November 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 October 2020
Resolved
Install a 2-A portable fire extinguisher in the passenger accommodation space. 46 CFR 181.500(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 November 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 October 2020
Resolved
Provide suitable brackets for the 40-B:C portable fire extinguishers that are located outside of the port and starboard machinery spaces. 46 CFR 181.500(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 November 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 October 2020
Resolved
Install metal supports no greater than 24” apart on electrical wiring in the port and starboard machinery spaces. 46 CFR 183.340(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 November 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 October 2020
Resolved
Secure fuel lines with nonferrous metal straps in the port and starboard machinery spaces. 46 CFR 182.455(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 November 2020
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 22 October 2020
Resolved
There is a cracked deck beam in the port hull, second compartment from bow. Complete temporary repairs w/in 14 days and permanent repairs at the next scheduled drydock.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 November 2020
Resolution: Vessel rep created an identical deck beam out of ash and epoxied it into place adjacent to the cracked deck beam identified during the previous inspection. This repair is consistent with the original design/construction and is acceptable as a permanent re
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 October 2019
Resolved
Replace/replace Port rudder post, post found with crevice corrosion near base of stainless steel post.
Action required: 705 - Other - as specified
Resolved 8 October 2019
Resolution: Stainless steel rudder post and internal extremities inside rudder were replaced and re-glassed.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 1 October 2019
Resolved
Repair portside inner forward hull per submitted plans on September 30th, make repair available for re-inspection prior to gel-coat or paint.
Action required: 705 - Other - as specified
Resolved 8 October 2019
Resolution: Hull repaired - Grind the area for a 12 to 1 ratio. Lay up with 2 layers of 1708 biaxial plus 1 layer of 1 1/2” matt with epoxy resin, sand and painted.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 1 October 2019
Resolved
Grind down cracks on hull crossover at hull connection point and make available for for re-inspection.
Action required: 705 - Other - as specified
Resolved 1 October 2019
Resolution: Areas ground down, no presence of structural cracks in framing. Areas re-glassed with single layer of biaxle.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 1 October 2019
Resolved
Repair/replace Port engine room ventilation system, ventilation piping found corroded and damaged
Action required: 705 - Other - as specified
Resolved 17 October 2019
Resolution: Ventilation replaced on aft STBD hull, ventilation tubing also replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 1 October 2019
Resolved
Demonstrate watertight integrity of Port and STBD Engine room spaces, access does not have deck coaming and engine room ventilation is below weather deck on inboard hull.
Action required: 705 - Other - as specified
Resolved 17 October 2019
Resolution: Deck gaskets replaced, achieved best possible weather tight integrity without completely redesigning deck hatch that had been approved at construction.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 1 October 2019
Resolved
Make all penetrations on watertight bulkheads watertight, bilge piping penetrations have not been sealed.
Action required: 705 - Other - as specified
Resolved 17 October 2019
Resolution: All bilge piping penetrations sealed with closed cell expanding foam.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 1 October 2019
Resolved
Repair deck on hull crossover, remove and replace damaged deck core and re-glass.
Action required: 705 - Other - as specified
Resolved 17 October 2019
Resolution: Deck repaired.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 October 2019
Resolved
Repair/replace running rigging roller for jib on STBD side, roller seized.
Action required: 705 - Other - as specified
Resolved 17 October 2019
Resolution: Entire roller assembly (03) replaced.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 1 October 2019
Resolved
Repair/replace metallic bilge piping on STBD side in way of chain plates in engine room. Bilge piping found corroded due to dissimilar metals.
Action required: 705 - Other - as specified
Resolved 17 October 2019
Resolution: Bilge piping replaced 8 feet sections on both top and bottom runs.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 1 October 2019
Resolved
Install vapor barrier on engine room doors to prevent the passage of vapors from engine room into washroom.
Action required: 705 - Other - as specified
Resolved 17 October 2019
Resolution: Gasket material lined around E/R doors.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 October 2019
Resolved
Provide drawings/plans of aluminum crossmember to demonstrate proper attachment for pelican striker STBD attachment point. Stainless steel cable is attached with a washer and nut on swageless fitting. Attachment point does not have provisions to prevent separating that potentially would allow the cable to be pulled from connection.
Action required: 705 - Other - as specified
Resolved 17 October 2019
Resolution: Crew re-installed 1/4in aluminum square in crossmember fitting to properly support. See attached pictures for setup, special note added to keep eye on arrangement.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 1 October 2019
Resolved
Repair deck beam in Port engine room, wood deck beam has angel hair.
Action required: 705 - Other - as specified
Resolved 17 October 2019
Resolution: Beams cleaned up and re-sealed with epoxy.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 1 October 2019
Resolved
Replace submersible bilge pump hose with a hose of suitable construction, metallic positive shutoff valve shall be located on hull penetration.
Action required: 705 - Other - as specified
Resolved 17 October 2019
Resolution: Positive shutoff valves installed in both E/R's.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 October 2019
Resolved
Provide written/email notification to local USCG for notice of change to vessels folding prop to fixed prop, included size, pitch.
Action required: 705 - Other - as specified
Resolved 1 October 2019
Resolution: Plans received, see attachment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 May 2018
Resolved
Replace starboard rudder
Action required: 17 - Rectify deficiencies prior to departure
Due 22 May 2018
Resolved 25 May 2018
Resolution: Rudder replaced.
Navigation › Collision/Grounding Avoidance › Radar
Issued 7 November 2017
Resolved
Provide and demonstrate proper operation of maine grade radar.
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 16 January 2018
Resolution: Demonstrated operation of radar.
Communications › Alarms/Indicators › High Water Alarm
Issued 7 November 2017
Resolved
Demonstrate proper operation of bilge high level alarm (port side forward of engine room).
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 16 January 2018
Resolution: verified operation
Communications › Radio Communications › VHF Radiotelephone
Issued 7 November 2017
Resolved
Program VF radio with MMSI # and provide GPS input.
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 16 January 2018
Resolution: MMSI# and GPS provided
Communications › Radio Communications › EPIRB
Issued 7 November 2017
Resolved
Replace hydrostatic release for EPIRB.
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 16 January 2018
Resolution: New hydrostatic release provided.
Lifesaving › Visual Distress Signals (General) › Storage
Issued 7 November 2017
Resolved
Provide watertight container for flares.
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 18 January 2018
Resolution: Watertight container provided.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 7 November 2017
Resolved
Replace retro tape on 58 PFD's, replace 03 Type I PFD's. (vessel reduced to carriage of 65 persons).
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 16 January 2018
Resolution: Retro reflective tape provided.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 November 2017
Resolved
Install guards on engines (Port/STBD).
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 16 January 2018
Resolution: Guards provided for both engines.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 7 November 2017
Resolved
Properly bond fuel tanks to a common bond. Bond fuel vent pipes.
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 16 January 2018
Resolution: Fuel tanks properly bonded.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 7 November 2017
Resolved
Make all penetrations to port aft engine room bulkheads watertight.
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 16 January 2018
Resolution: Bulkhead made watertight.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 November 2017
Resolved
Provide first aid kit IAW 46CFR160.041
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 16 January 2018
Resolution: All contents provided meeting 160.041
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 7 November 2017
Resolved
Provide waste managment plan.
Due 7 December 2017
Resolved 16 January 2018
Resolution: Plan provided.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 7 November 2017
Resolved
Post emergency instructions.
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 16 January 2018
Resolution: Instructions posted.
Documentation › Certificates/Documents › Stability Letter
Issued 5 October 2016
Resolved
Provide copy of approved sail plan to attending marine inspector or submit plan to MSC for approval
Action required: 705 - Other - as specified
Due 5 November 2016
Resolved 13 October 2016
Resolution: Received approved sail plan from MSC
Lifesaving › Lifefloat › Serviceable
Issued 5 October 2016
Resolved
Repair/renew life floats to serviceable condition. Vessel restricted to operating no more than 3 miles from shore.
Action required: 705 - Other - as specified
Due 5 November 2016
Resolved 6 December 2016
Resolution: Renewed life floats
Construction/Loadline › Structures › Transverse Bulkhead
Issued 5 October 2016
Resolved
Make forward engine room bulkheads vapor tight at pipe penetrations
Action required: 705 - Other - as specified
Due 5 November 2016
Resolved 7 October 2016
Resolution: Penetrations were made vapor tight
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 October 2016
Resolved
Provide plans to make permanent repairs to railing. Rail course exceed the 4" requirement
Action required: 705 - Other - as specified
Due 5 November 2016
Resolved 31 October 2016
Resolution: Installed life lines per approved plan.
Communications › Radio Communications › VHF Radiotelephone
Issued 8 January 2016
Resolved
Program MMSI number from Radio Station Authorization into VHF radio.
Action required: 705 - Other - as specified
Due 8 February 2016
Resolved 9 January 2016
Resolution: Received photo verification from vessel SEBAGO CUBED, O.N. 996733 that their VHF radio was programmed with their assigned MMSI number.
Engineering › Bilge Water Management System › Piping
Issued 8 January 2016
Resolved
Install positive shutoff valve at automatic submersible bilge pump through hulls in both port and starboard automatic bilge pump lines.
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 15 December 2016
Engineering › Bilge Water Management System › Interface Detector
Issued 8 January 2016
Resolved
Install visual indicator at operating station to identify when automatic bilge pumps are operating.
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 15 December 2016