← All vessels
SEMELE
Freight Ship · General Dry Cargo Ship class · Built 1970s · USCG Southeast District (CGD-SE) · Other hulls named SEMELE
SEMELE is a 1976 freight ship. The Coast Guard has recorded 28 inspections since 1993, most recently in November 1998, along with 95 deficiencies and 2 operational controls.
Records from 1993 to 1998. Most recent: inspection, 13 November 1998.
- Built
- 1976
- Last inspected
- 13 November 1998
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 95 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7523221 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V3WJ5
394778
Flag
CYPRUS
—
Maury page id
psix-394778
Inspections, by type
The 28 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it5744 - Regulatory (Subpart C or D), Gross Ton
3010 - Regulatory (Subpart C or D), Net Ton
7085 - Dead Weight, Ton
3010 - Regulatory (Subpart C or D), Net Ton
7085 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 28
13 November 1998
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 729797
2 November 1998
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 416351
6 September 1998
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 695846
3 June 1998
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 202948
19 March 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 413902
2 February 1998
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 412723
21 January 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 412003
19 March 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 401564
29 January 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 399964
19 June 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 392346
2 January 1996
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 202947
2 January 1996
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 760567
11 October 1995
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 383607
6 September 1995
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 695847
17 August 1995
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 381346
15 March 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 684690
13 March 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 376159
28 December 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 373854
26 October 1994
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 684688
14 October 1994
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 684691
10 October 1994
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 371713
10 October 1994
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1174304
7 October 1994
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 371179
6 October 1994
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 370864
6 October 1994
Uninspected Other
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1177116
7 October 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 695848
22 September 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 695845
9 September 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 52728
Deficiency record · 95
Documentation
Issued 21 January 1998
Resolved
STABILITY BOOKLET AND LOADING INFORMATION MISSING. CORRECT TO THE SATISFACTION OF ATTENDING USCG INSPECTOR IAW ILCC 66 ANNEX I/10 NLT _x001C_ 04FEB98.
Lifesaving
Issued 21 January 1998
Resolved
EXPOSED WIRING IN FLAMMABLE LIQUIS/PAINT LOCKER. CORRECT TO SATISFACTION_x001C_ OF USCG INSPECTOR PRIOR TO DEPARTURE FROM HOUSTON, TX IAW SOLAS 60 II/27_x001C_ NLT 22JAN98.
Lifesaving
Issued 21 January 1998
Resolved
TRAINING RECORDS FOR HAZMAT CREWMEMBERS MISSING. CORRECT TO SATISFACTION OF ATTENDING USCG INSPECTOR PRIOR TO DEPARTURE FROM THE PORT OF HOUSTON, TXIAW 49CFR172.704 NLT 22JAN98._x001C_
Fire Fighting
Issued 21 January 1998
Resolved
CO2 CYLINDERS (APPROX 10) MISSING SAFETY SEALS. CORRECT IAW SOLAS 60_x001C_ REG II/58 NLT 31JAN98.
Lifesaving
Issued 21 January 1998
Resolved
WATERTIGHT AND WEATHERTIGHT HATCHES, GASKETS & DOGS DETERIORATED. CORRECT TO THE SATISFACTION OF CLASS SOCIETY, INCLAMAR, IAW ILCC 66 ANNEX I/12_x001C_ NLT 01MAR98.
Engineering
Issued 21 January 1998
Resolved
SOFT PATCHES ON MAJORITY OF PIPING IN ENGINE ROOM. MAKE PERMANENT REPAIRS_x001C_IAW SOLAS 60 REG II NLT 01MAR98.
Lifesaving
Issued 21 January 1998
Resolved
LIMIT SWITCHES ON BOTH PORT AND STARBOARD SIDE DAVITS INOPERABLE. CORRECT TO THE SATISFACTION OF CLASS SOCIETY, INCLAMAR, IAW SOLAS 60 REG III/36_x001C_ NLT 31JAN98.
Lifesaving
Issued 21 January 1998
Resolved
RETROREFLECTIVE TAPE NOT PROPERLY PLACED ON LIFEBOATS. CORRECT PRIOR TO_x001C_ NEXT U.S. PORT NLT 01FEB98 IAW SOLAS 74 (AMENDED) REG III/30.2.7.
Engineering
Issued 21 January 1998
Resolved
EXCESSIVE FUEL LEAK IN THE #3 GENERATOR. CORRECT TO THE SATISFACTION OF ATTENDING USCG INSPECTOR PRIOR TO DEPARTURE FROM HOUSTON, TX IAW SOLAS 60 I/10 NLT 22JAN98._x001C_
Engineering
Issued 21 January 1998
Resolved
EXCESSIVE OIL IN MACHINERY SPACE AND ON MAIN ENGINES. CORRECT TO SATISFACTION OF ATTENDING USCG INSPECTOR PRIOR TO DEPARTURE HOUSTON, TX _x001C_ IAW SOLAS 60 II/34 NLT 22JAN98.
Electrical
Issued 21 January 1998
Resolved
MAIN ENGINE ELECTRICAL CONTROLS EXPOSED. CORRECT TO THE SATISFACTION OF ATTENDING USCG INSPECTOR PRIOR TO DEPARTURE FROM HOUSTON, TX IAW SOLAS 60 II/27 NLT 22JAN98.
Deck/Cargo
Issued 21 January 1998
Resolved
HATCHES WITH WEATHERTIGHT STEEL COVERS USING GASKETS AND CLAMPING DEVICES NOT WEATHERTIGHT. CORRECT TO THE SATISFACTION OF CLASS SOCIETY, INCLAMAR,_x001C_NLT 01MAR98 IAW ILCC 66 ANNEX I/16.
Lifesaving
Issued 21 January 1998
Resolved
FLAMMABLE LIQUIDS IMPROPERLY STOWED IN THE PAINT LOCKER. CORRECT TO SATISFACTION OF ATTENDING USCG INSPECTOR PRIOR TO DEPARTURE FROM HOUSTON, TX., IAW SOLAS 60 II/45 NLT 22JAN98._x001C_ _x001C_
Navigation
Issued 21 January 1998
Resolved
NAVIGATIONAL LIGHTS INOPERABLE. REPAIR/TEST TO SATISFACTION OF LOCAL OCMI_x001C_IAW 72 COLREGS RULE 20 PRIOR TO DEPARTURE FROM PORT OF HOUSTON, NLT 31JAN98.
Fire Fighting
Issued 21 January 1998
Resolved
UNSATISFACTORY FIRE DRILL. CONDUCT SATISFACTORY DRILL IN THE PRESENCE OF LOCAL [name withheld] FROM THE PORT OF HOUSTON IAW SOLAS 74 (AMENDED) REG III/53 NLT 31JAN98.
Documentation
Issued 21 January 1998
Resolved
PRE-ARRIVAL TESTS NOT LOGGED. CORRECT PRIOR TO ENTRY INTO NEXT U.S. PORT_x001C_ IAW 33CFR164.25.
Unknown
Issued 21 January 1998
Resolved
NO WATER OR LIGHTS IN HOSPITAL SPACE. PROVIDE/REPLACE NLT 01MAR98 IAW _x001C_ ILO 147.
Construction/Loadline
Issued 21 January 1998
Resolved
WEATHERTIGHT DOORS ABOVE MAIN DECK DO NOT PROPERLY CLOSE. REPAIR TO THE SATISFACTION OF CLASS SOCIETY, INCLAMAR, IAW ILCC 66 NLT 01MAR98.
Electrical
Issued 21 January 1998
Resolved
BATTERIES STOWED IMPROPERLY IN PYROLOCKER. REMOVE PRIOR TO NEXT U.S. PORT NLT 01FEB98 IAW SOLAS 60/REG 27(A)(8)._x001C_
Electrical
Issued 21 January 1998
Resolved
EMERGENCY BATTERIES FOR RADIO ROOM DO NOT FIT IN BATTERY TRAY. PROPERLY STOW BATTERIES IAW SOLAS 60 II/27(A)(8) NLT 23JAN98.
Electrical
Issued 21 January 1998
Resolved
MISSING NUMEROUS LIGHTS AND LIGHT COVERS THROUGHOUT VESSEL. REPAIR/REPLACEIAW ILO 147 NLT 01MAR98.
Unknown
Issued 21 January 1998
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving
Issued 21 January 1998
Resolved
INSTRUCTIONS FOR ONBOARD MAINTENANCE OF LIFESAVING EQUIPMENT MISSING. CORRECT TO SATISFACTION OF ATTENDING USCG INSPECTOR IAW SOLAS 74(AMENDED)_x001C_ REG III/19.3 NLT 04FEB98.
Deck/Cargo
Issued 21 January 1998
Resolved
DANGEROUS CARGO MANIFEST MISSING. CORRECT TO THE SATISFACTION OF ATTENDINGUSCG INSPECTOR IAW 49CFR176.30 PRIOR TO DEPARTURE FROM THE PORT OF HOUSTON,TX. NLT 22JAN98.
Deck/Cargo
Issued 21 January 1998
Resolved
SHIPPING PAPERS NOT PRESENT. CORRECT TO THE SATISFACTION OF ATTENDING USCG MARINE INSPECTOR IAW SOLAS 60 REG. VII/5 NLT 22JAN98.
Construction/Loadline
Issued 29 January 1997
Resolved
MAKE PERMANENT REPAIR FOR ALL AROUND EDGE OF THE AFT WATERTIGHT HATCH COVERAT NEXT DRYDOCK PERIOD 07FEB97.
Fire Fighting
Issued 29 January 1997
Resolved
CROP AND RENEW FOR ONE FIREMAIN SECTION ON STBD SIDE FORWARD OF SUPERSTRUCTURE.
Lifesaving
Issued 29 January 1997
Resolved
PROVE PROPER OPERATION FOR BOTH LIFEBOATS MOTOR.
Fire Fighting
Issued 29 January 1997
Resolved
UPDATE UNREADABLE FIRE PLAN IN 01 PASSAGEWAY.
Lifesaving
Issued 29 January 1997
Resolved
PROVIDE EXPIRATION OR OPERATE DATE OF EPIRB HYDROSTATIC RELEASE.
Electrical
Issued 29 January 1997
Resolved
PROVIDE AND RENEW LIGHT BULBS AND COVERS: A)AFT SAFETY LOCKER B)FORWARD SAFETY LOCKER C)MAINDECK STBD SIDE. LEFT OF LADDER.BY PASSAGEWAY LEADING INTO MAIN HOUSE.
Lifesaving
Issued 29 January 1997
Resolved
RELOCATE ALL LIFESAVING EQUIPMENT ITEMS IN IT PROPER LOCATION. (EX. LIFEBOAT EQUIPMENT, LIFE BUOYS.)
Accommodation/Occupational Safety
Issued 29 January 1997
Resolved
CLEAN OVERHEAD OVEN GREASE TRAP IN THE GALLEY.
Accommodation/Occupational Safety
Issued 29 January 1997
Resolved
VESSEL TO IMPLEMENT PLAN FOR SEGREGATING GARBAGE AND DISPOSE PLASTIC PROPERLY. SEE COMMENT.*** BOARDING TEAM SHOULD BE ON THE LOOK-OUT FOR POSSIBLE MARPOL V VIOLATION.***
Lifesaving
Issued 19 June 1996
Resolved
RENEW/REPAIR/REPLACE GRABLINE ON LIFERING BOUY LOCATED STARBOARD SIDE MAIN DECK OUTSIDE PAINT LOCKER._x001C_ SOLAS 74(AMENDED) III/17.2
Accommodation/Occupational Safety
Issued 19 June 1996
Resolved
RENEW/REPAIR DETERIORATED VENTILATION CLOSURE LOCATED ON THE BRIDGE DECK STARBOARD SIDE, 03 DECJ AFT #27, 02 DECK AFT TO BATTERY ROOM, POOP DECK PORT SIDE (NO GASKET), AND THE VENTILATION CLOSURE ON THE WATERTIGHT DOOR BETWEEN CARGO HOLDS 2 AND 3. SOLAS 60 II/47(a)
Accommodation/Occupational Safety
Issued 19 June 1996
Resolved
RENEW/REPAIR WASTED WATERTIGHT DOOR, 03 DECK AFT. SOLAS 60 II/17(a)
Lifesaving
Issued 19 June 1996
Resolved
RENEW DETERIORATED RETRO REFLECTIVE TAPE ON RING BUOYS LOCATED ON THE PORT & STARBOARD SIDES OF BRIDGE WINGS. SOLAS 74(AMENDED) III/30.2.7
Lifesaving
Issued 19 June 1996
Resolved
RENEW DETERIORATED RETRO REFLECTIVE TAPE ON PORT AND STARBOARD SIDE LIFEBOATS. SOLAS 74 (AMENDED) III/30.2.7
Documentation
Issued 17 August 1995
Resolved
PROVIDE MEDICAL LOG FOR HOSPITAL. (MISSING)
Accommodation/Occupational Safety
Issued 17 August 1995
Resolved
CLEAN DISPENSARY. (UNSANITARY)
Unknown
Issued 17 August 1995
Resolved
DISPOSE OF EXPIRED MEDICATION IN HOSPITAL SPACE.
Accommodation/Occupational Safety
Issued 17 August 1995
Resolved
CLEAN GALLEY. (UNSANITARY)
Accommodation/Occupational Safety
Issued 17 August 1995
Resolved
MAKE REPAIRS TO VEGETABLE AND MEAT REEFERS. (NON-OPERATIONAL)
Accommodation/Occupational Safety
Issued 17 August 1995
Resolved
REPLENISH SHIP STORES. (FOOD INVENTORY TOO LOW FOR CREW AND PLANNED VOYAGE)
Accommodation/Occupational Safety
Issued 17 August 1995
Resolved
MAKE PERMANENT REPAIRS TO LADDERWAY FROM BRIDGE DECK. (WASTED) (CLASS TO VERIFY REPAIRS)
Unknown
Issued 17 August 1995
Resolved
CLEAN EXCESSIVE OIL FROM EQUIPMENT IN ENGINE ROOM. (FIRE HAZARD)
Documentation
Issued 17 August 1995
Resolved
PROVIDE ON BOARD VALID SAFETY CONSTRUCTION CERTIFICATE. (MISSING) (CLASS TO VERIFY VALIDITY)
Documentation
Issued 17 August 1995
Resolved
PROVE VALIDITY OF IOPP AND SAFETY EQUIPMENT CERTIFICATES. (EQUIPMENT DIFFERED FROM CERTIFICATE REQUIREMENTS) (CLASS TO VERIFY CERTIFICATES)
Deck/Cargo
Issued 17 August 1995
Resolved
REPLACE HANDLE FOR STARBOARD ANCHOR WINCH MOTOR. (WASTED)
Documentation
Issued 17 August 1995
Resolved
PROVIDE SHIP BOARD OIL POLLUTION PLAN FOR VESSEL. (MISSING) (FLAG STATE TOAPPROVE)
Documentation
Issued 17 August 1995
Resolved
POST POLLUTION PLACARD NEAR OVERBOARD DISCHARGE CONTROL FOR OILY-WATER SEPARATOR. (MISSING)
Engineering
Issued 17 August 1995
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR. (INOPERABLE) (CLASS TO VERIFY REPAIRS)
Fire Fighting
Issued 17 August 1995
Resolved
MAKE REPAIRS AND PROVE PROPER OPERATION OF EMERGENCY FIREPUMP. (NOT GETTING SUCTION) (CLASS TO VERIFY REPAIRS)
Fire Fighting
Issued 17 August 1995
Resolved
UPDATE FIRE CONTROL PLANS. (PLAN DID NOT ACCURATELY REFLECT VESSEL'S INSTALLED EQUIPMENT)
Lifesaving
Issued 17 August 1995
Resolved
POST INSTRUCTIONS FOR LIFESAVING APPLIANCES. (MISSING) (CLASS TO VERIFY POSTING OF INSTRUCTIONS)
Lifesaving
Issued 17 August 1995
Resolved
PROVIDE MAINTENACE LOG FOR SAFETY EQUIPMENT. (MISSING)
Construction/Loadline
Issued 17 August 1995
Resolved
MAKE PERMANENT REPAIRS AND PROVE PROPER OPERATION OF BILGE PUMPS. (INOPERABLE) (CLASS TO VERIFY REPAIRS AND PROPER OPERATION)
Fire Fighting
Issued 17 August 1995
Resolved
PROVE PROPER OPERATION OF PRIMARY AND SECONDARY FIRE PUMPS. (UNABLE TO TEST) (CLASS TO VERIFY PROPER OPERATION)
Fire Fighting
Issued 17 August 1995
Resolved
PROVIDE SERVICABLE NOZZLES FOR ALL FIRE STATIONS. (FROZEN IN PLACE) (CLASSTO VERIFY ALL NOZZLES SERVICABILITY)
Fire Fighting
Issued 17 August 1995
Resolved
REPAIR LEAKING FIRE HYDRANTS. (CLASS TO VERIFY REPAIRS)
Fire Fighting
Issued 17 August 1995
Resolved
MAKE PERMANENT REPAIRS TO FIRE MAIN PIPING NAVIGATION BRIDGE DECK. (LEAKS)(CLASS TO VERIFY REPAIRS)
Lifesaving
Issued 17 August 1995
Resolved
REPLACE 06 UNSERVICABLE LIFE BUOYS. (DRY ROTTED LINE) (CLASS TO VERIFY ALLSERVICABLE LIFE BUOYS)
Fire Fighting
Issued 17 August 1995
Resolved
PROVE PROPER OPERATION OF CO2 ALARM. (OPERATING PREMATURELY) (CLASS TO VERIFY PROPER OPERATION)
Construction/Loadline
Issued 17 August 1995
Resolved
MAKE PERMANENT REPAIRS TO WATERTIGHT DOOR STARBOARD SIDE DECK HOUSE. (HOLED) (CLASS TO VERIFY REPAIRS)
Electrical
Issued 17 August 1995
Resolved
REPLACE PROTECTIVE LIGHT COVERS FOR LIGHTS IN ENGINE ROOM. (MISSING)
Accommodation/Occupational Safety
Issued 13 March 1995
Resolved
PROVIDE ENOUGH FOOD ON VESSEL FOR THE CREW. (ILO 147)
Accommodation/Occupational Safety
Issued 13 March 1995
Resolved
GREASE SCREENS ABOVE STOVE IN GALLEY, NEED TO BE CLEANED. (ILO 147)
Navigation
Issued 13 March 1995
Resolved
ALL CHARTS LISTED BELOW ARE NOT CURRENTLY CORRECTED/UPDATED:_x001C_ 11361 - 94/50 11370 - NO CORRECTIONS_x001C_ 11364 - 94/37_x001C_ 11368 - 93/34 CG8, 41, 43 (33 CFR 164.33(a)(1)(ii))_x001C_
Accommodation/Occupational Safety
Issued 13 March 1995
Resolved
VEGETABLE REFER INOPERABLE. (ILO 147)
Accommodation/Occupational Safety
Issued 13 March 1995
Resolved
REMOVE CYLINDER FROM DRY STORAGE AREA. (ILO 147)
Accommodation/Occupational Safety
Issued 13 March 1995
Resolved
OUTDATED MEDICINE IN HOSPITAL SPACE. (ILO 147)
Engineering
Issued 13 March 1995
Resolved
GENERAL CLEANING IN ENGINE ROOM. (SOLAS II)
Navigation
Issued 13 March 1995
Resolved
EXCESSIVE OIL ON DECK, IN AFT STEERING. (SOLAS II)
Navigation
Issued 13 March 1995
Resolved
INSTALL NON-SKID ON THE DECK IN AFT STEERING. (SOLAS II)
Lifesaving
Issued 13 March 1995
Resolved
PORTSIDE LIFEBOAT GEARING INOPERABLE, COULD NOT GO AHEAD/ASTERN._x001C_ (SOLAS III)
Engineering
Issued 13 March 1995
Resolved
OILYWATER SEPARATOR ALARM INOPERABLE. (33 CFR 155.380)
Navigation
Issued 13 March 1995
Resolved
COAST PILOT V 1992, OUTDATED WITH NO CORRECTIONS NOTED. _x001C_ (33 CFR 164.33(a)(2)(i))
Navigation
Issued 13 March 1995
Resolved
USCG LIGHT LIST VOLUME (4) EDITION 1993, LAST CORRECTION NOTED 94/44. _x001C_ (33 CFR 164.33(a)(2)(ii))
Engineering
Issued 28 December 1994
Resolved
VESSEL DID NOT HAVE FIXED CONTAINMENT WELDED TO DECK. THEY HAD BARRELS BOLTED TO A HANDRAIL WHICH IS SEMI-FIXED.
Fire Fighting
Issued 10 October 1994
Resolved
VSL DID NOT HAVE DUPLICATE SET OF FIRE CONTROL PLANS IN A PROMINENTLY MARKED, WEATHERTIGHT ENCLOSURE OUTSIDE THE DECKHOUSE, AS REQUIRED BY SOLAS 74/78, CHAPT. II-2, REG. 20.2.
Navigation
Issued 10 October 1994
Resolved
VSL DID NOT HAVE NOS CHART #13292 OR EQUIVALENT THAT WOULD PROVIDE LARGEENOUGH SCALE AND ENOUGH DETAIL OF THE CASCO BAY AND PORTLAND HARBOR AREA TOMAKE SAFE NAVIGATION OF THE AREA POSSIBLE.
Lifesaving
Issued 10 October 1994
Resolved
VSL DID NOT HAVE REQUISITE OPERATIONAL SELF-IGNITING LIGHTS ASSOCIATED WITH RING BUOYS AS REQUIRED BY SOLAS 74/78, CHAPT. III, REGULATION 7.1.3.
Navigation
Issued 10 October 1994
Resolved
VSL DID NOT HAVE 1994 NOS TIDAL CURRENT TABLES FOR EAST COAST OF U.S.
Navigation
Issued 10 October 1994
Resolved
VSL DID NOT HAVE A COPY OF INLAND NAVIGATION RULES.
Engineering
Issued 10 October 1994
Resolved
VSL DID NOT HAVE ADEQUATE FIXED FUEL OIL CONTAINMENT ON BOTH PORT AND STARBOARD SIDES.
Fire Fighting
Issued 7 October 1994
Resolved
VSL HAS NO SET OF FIRE CONTROL PLANS PERMANENTLY STORED IN A PROMINENTLY MARKED WEATHERTIGHT ENCLOSURE OUTSIDE DECKHOUSE._x001C_ SOLAS CHAP. II-2 REG. 20 2
Engineering
Issued 7 October 1994
Resolved
VSL BUILT IN 1976. VSL HAS NO FIXED CONTAINER OR ENCLOSED DECK AREA AROUNDPORT & STBD FUEL OIL FILL PIPES. NO BUNKERING OPS PERMITTED UNTIL DISCREPANCY CORRECTED.
Lifesaving
Issued 6 October 1994
Resolved
While inspecting the vessel's log, it was noted that there was no entry for pre-arrival tests. When the master was asked about this, he stated that he forgot to conduct the tests.
Navigation
Issued 6 October 1994
Resolved
Maneuvering fact sheet was not sufficient and was missing information.
Engineering
Issued 6 October 1994
Resolved
REPAIR/REPLACE THE FOLLOWING FLAME SCREENS: TANK NO. 2.11 DIRTY OIL, F.W.T.M/E EXP. TANK, HYD. OIL NO. 2.12, LUBE OIL TANK NO. 2.14 AND 2.16, IFO M/E MIX TANK, IFO TANK 1.8.
Lifesaving
Issued 6 October 1994
Resolved
COVER OPEN CANS OF PAINT THINNER IN PAINT LOCKER AND PROVIDE CLOSED CANS FOR CLEANING PAINT BRUSHES.
Lifesaving
Issued 6 October 1994
Resolved
REPLACE DEGRADED RETRO-REFLECTIVE TAPE ON ALL LIFERINGS.
Lifesaving
Issued 6 October 1994
Resolved
REPLACE DEGRADED AND PAINTED OVER RETRO-REFLECTIVE TAPE ON BOTH LIFEBOATS.
Lifesaving
Issued 6 October 1994
Resolved
PROVIDE WATER PROOF PORTABLE CONTAINERS FOR ALL PYROTECHNICS ON BOTH LIFEBOATS.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.