Records from 1997 to 2016. Most recent: inspection, 5 August 2016.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 9
5 August 2016
Loadline Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5963584
11 February 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 775027
4 November 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1118679
10 October 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 112345
30 September 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1452337
28 July 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 679457
28 July 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 770887
12 June 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 199930
12 June 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 209137
Construction/Loadline
Issued 30 September 1997
Resolved
PLUG OPEN STUFFING TUBE IN THE BULKHEAD TO THE TO THE MUD PIT ROOM.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Fire Fighting
Issued 30 September 1997
Resolved
PROVIDE PROOF OF APPROVAL OF FIRE PLANS.
Condition: Unknown
Due 30 September 1997
Resolved 30 September 1997
Lifesaving
Issued 30 September 1997
Resolved
PROPERLY INSTALL EYEWASH STATIONS IN THE MUDPIT AREA, SHALE SHAKER AREA ANDTHE DRILL FLOOR.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Fire Fighting
Issued 30 September 1997
Resolved
PROOOVIDE OPERATING INSTRUCTIONS FOR THE PAINT LOCKER CO2 SYSTEM.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Navigation
Issued 30 September 1997
Resolved
REPLACE THE OBSTRUCTION LIGHT LENSES FOR THE AFT PORT AND AFT STARBOARD LIGHTS.
Condition: Unknown
Due 30 September 1997
Resolved 30 September 1997
Accommodation/Occupational Safety
Issued 30 September 1997
Resolved
CROP AND RENEW PORT SIDE HAND RAIL AT THE LIFE CAPSULE.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Electrical
Issued 30 September 1997
Resolved
INSTALL BLANKS IN DISTRIBUTION PANELS THROUGHOUT THE RIG AS NEEDED AND LABEL ALL BREAKERS.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Construction/Loadline
Issued 30 September 1997
Resolved
INSTALL PROPER GASKET MATERIAL IN ALL WTD'S BELOW DECKS.
Condition: Unknown
Due 30 September 1997
Resolved 30 September 1997
Electrical
Issued 30 September 1997
Resolved
INSTALL A LINING IN THE NAV LIGHT BATTERY BOX.
Condition: Unknown
Due 30 September 1997
Resolved 30 September 1997
Electrical
Issued 30 September 1997
Resolved
REPLACE ALL LIMIT SWITCHES FOR THE LIFE BOAT CAPSULES.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Accommodation/Occupational Safety
Issued 30 September 1997
Resolved
CROP AND RENEW THE STBD SIDE HANDRAIL TO THE HELO DECK.
Condition: Unknown
Due 24 October 1997
Resolved 24 October 1997
Fire Fighting
Issued 30 September 1997
Resolved
NUMBER ALL FIRE HOSE STATIONS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Construction/Loadline
Issued 30 September 1997
Resolved
REPAIR THE BENT LADDER TO THE PORT SIDE CRANE.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Accommodation/Occupational Safety
Issued 30 September 1997
Resolved
REPAIR VENTILATION SHUT DOWN.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Engineering
Issued 30 September 1997
Resolved
PROVE OPERATION OF THE REMOTE SHUTDOWN FOR THE #1 FUEL OIL TRANSFER PUMP.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997