JOSEPHINE MAERSK is a 2002 freight ship. The Coast Guard has recorded 5 inspections since 2019, most recently in September 2024, along with 3 deficiencies and 1 operational control.
Records from 2019 to 2024. Most recent: inspection, 16 September 2024.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it35131 - Dead Weight, Metric Ton 49343 - Displacement, Metric Ton 31119 - Regulatory (Subpart C or D), Gross Ton 30166 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 May 2024Resolved
THE RING LINES, AND LETTERS SHALL BE PRINTED IN WHITE OR YELLOW ON A DARK BNACKGROUND OR IN BLACK ON A LIGHT BACKGROUND. PSCO OBSERVED LOAD LINE WAS NOT CLEARLY VISIBLE.
ICLL 8
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 June 2024
Resolved 21 June 2024
Resolution: rcvd class rep
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 May 2024Resolved
BOUNDARIES OF CARGO SHIPS SHALL MEET TABLE 9.5 OF SOLAS II-2. DOOR BETWEEN PAINT LOCKER AND STEERING GEAR SPACE DOES NOT MEET REQUIREMENTS OUTLINED IN TABLE 9.5. DOOR IS A B-15 IN AN A-0 BOUNDARY.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 June 2024
Resolved 21 June 2024
Resolution: rcvd class rep
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 February 2019Resolved
Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. Emergency fire pump woould not work as intended. Vessels emergency fire pump is located in the forward Bosn Hold. Vesssel was not able to receive suction or prime pump for use.
74 SOLAS(14)II-2/14.2.1.2
Code 07113
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2019
Resolved 26 February 2019
Resolution: Vessel was able to rectify issue and prove operational function of system.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.