← All vessels
UNICOSTA
UNICOSTA is a 1980 freight ship. The Coast Guard has recorded 6 inspections since 1994, most recently in October 1997, along with 50 deficiencies and 2 operational controls.
Records from 1994 to 1997. Most recent: operational control imposed, 28 October 1997.
- Built
- 1980
- Last inspected
- 28 October 1997
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 50 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8030984 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
PJQD
395504
Flag
NETHERLANDS ANTILLES
—
Maury page id
psix-395504
Inspections, by type
The 6 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it10970 - Convention (Subpart B), Gross Ton
6188 - Convention (Subpart B), Net Ton
13655 - Dead Weight, Ton
6188 - Convention (Subpart B), Net Ton
13655 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 6
28 October 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 409456
8 May 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 403548
22 May 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 391504
22 March 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 389109
9 December 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 373346
9 December 1994
Control Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1144989
Deficiency record · 50
Navigation
Issued 8 May 1997
Resolved
Vessel's echo sounder needs calibration check. (33CFR164.11(r)).
Lifesaving
Issued 22 March 1996
Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER COOLING SUPPLY PIPING TO #2 FREEZER COMPRESSOR LOCATED 2ND LEVEL ENGINE ROOM STBD SIDE.
Lifesaving
Issued 22 March 1996
Resolved
REPAIR AND PROVE SATISFACTORY OPERATION OF THE PORT LIFEBOAT ENGINE._x001C_ SOLAS 60 III/19(a)(iii)
Lifesaving
Issued 22 March 1996
Resolved
REMOVE EXCESS OIL AND OIL RESIDUE FROM CONTAINMENT THROUGHOUT THE ENG. SPACES.
Lifesaving
Issued 22 March 1996
Resolved
REMOVE EXCESS OIL AND OIL RESIDUE FROM THE ENG. ROOM BILGES.
Electrical
Issued 22 March 1996
Resolved
REMOVE BROKEN LIGHT FIXTURE LOCATED OVER #1 GENERATOR
Lifesaving
Issued 22 March 1996
Resolved
REMOVE EXCESS OIL AND OIL RESIDUE FROM BENEATH THE DECK PLATES IN THE PURIFIER/SEPERATOR ROOM.
Lifesaving
Issued 22 March 1996
Resolved
PROVIDE ONBOARD AT LEAST TWO RING LIFE BOUYS PROVIDED WITH SELF IGNITING_x001C_ LIGHTS AND SELF ACTIVATING SMOKE SIGNAL CAPABLE OF QUICK RELEASE FROM THE_x001C_ NAVIGATING BRIDGE.
Fire Fighting
Issued 22 March 1996
Resolved
RENEW AS ORIGINAL DETERIORATED FIRE MAIN PIPING TO FIRE HYDRANT LOCATED ON_x001C_THE STARBOARD BRIDGE WING. SOLAS 74 (AMENDED) II-2/21
Fire Fighting
Issued 22 March 1996
Resolved
RENEW AS ORIGINAL DETERIORATED FIRE MAIN PIPING TO FIRE HYDRANT LOCATED_x001C_ ON THE PORT BRIDGE WING. SOLAS 74 (AMENDED) II-2/21
Lifesaving
Issued 22 March 1996
Resolved
SECURE LOSE BATTRIES LOCATED IN THE BATTERY STORAGE ROOM AFT ON THE BRIDGE DECK.
Lifesaving
Issued 22 March 1996
Resolved
RENEW ALL DEFECTIVE RING LIFE BOUYS THROUGH OUT THE VESSEL. SOLAS 74_x001C_ (AMENDED) III/19.2
Lifesaving
Issued 22 March 1996
Resolved
RENEW ALL DEFECTIVE WATER LIGHTS TO RING LIFE BOUYS IN ACCORDANCE WITH FIRECONTROL PLAN THAT ARE IN SERVICIEABLE CONDITION. SOLAS 74 (AMENDED) III/19.2
Lifesaving
Issued 22 March 1996
Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER PIPE LOCATED IN THE ENGINE ROOM LOWER LEVEL STBD SIDE ABOVE VALVE #22
Lifesaving
Issued 22 March 1996
Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER COOLING PIPE LOCATED IN THE ENGINEROOM LOWER STBD SIDE ABOVE VALVE #20
Fire Fighting
Issued 22 March 1996
Resolved
ROVIDE ONBOARD FIRE NOZZLES TO EACH FIRE STATION. SOLAS 60 II/65(c)(i)
Fire Fighting
Issued 22 March 1996
Resolved
RENEW/ REPAIR INOPERABLE NATURAL VENTILATION CLOSURES LOCATED ON THE STARBOARD BOAT DECK. SOLAS 60 II/47(a)
Fire Fighting
Issued 22 March 1996
Resolved
RENEW/ REPAIR INOPERABLE VENTILATION DOORS LOCATED AFT CENTERLINE ON THE_x001C_ BOAT DECK. SOLAS 60 II/47(a)
Fire Fighting
Issued 22 March 1996
Resolved
RENEW/ REPAIR INOPERABLE VENTILATION DOORS LOCATED INSIDE THE MAIN FAN_x001C_ ROOM ON THE PORT SIDE. MAIN FAN ROOM LOCATED CENTERLINE ON THE BOAT DECK.
Lifesaving
Issued 22 March 1996
Resolved
RENEW/ REPAIR INOPERABLE LIFEBOAT EMBARKATION LIGHT (AFT LIGHT) FOR THE_x001C_ PORT LIFEBOAT. SOLAS 60 III/19(a)(ii)_x001C_
Navigation
Issued 22 March 1996
Resolved
RENEW/REPAIR INOPERABLE RADIO DIRECTION FINDER._x001C_ SOLAS 74 AMENDED V/12(p)
Unknown
Issued 22 March 1996
Resolved
REMOVE FOOD STORED IN THE HOSPITAL REFRIDGERATOR.
Lifesaving
Issued 22 March 1996
Resolved
REMOVE PAINT STORED IN THE EMERGENCY LOCKER_x001C_ SOLAS 74 AMENDED II-2/18.7
Lifesaving
Issued 22 March 1996
Resolved
PROVIDE FOR BOTH LIFEBOATS 2 BUCKETS AND 1 GALLON OF VEGTABLE OIL_x001C_ SOLAS 60 III/11(a)(ii)(xi)
Lifesaving
Issued 22 March 1996
Resolved
PROVIDE EVIDENCE THAT THE LIFEBOAT DAVIT FALLS HAVE BEEN RENEWED WITHIN 5 YEARS AND OR END FOR ENDED WITHIN 30 MONTHS._x001C_ SOLAS 74 AMENDED III/19.4
Navigation
Issued 22 March 1996
Resolved
PROVIDE ONBOARD VESSEL CORRECTED TO DATE COPIES OF THE FOLLOWING PUBLICATIONS: SAILING DIRECTIONS, LIGHT LIST, TIDE TABLES, COAST PILOT, ADEQUATE CHARTS FOR THE MOBILE AREA. (11376)_x001C_ SOLAS 74 AMENDED V/20
Navigation
Issued 22 March 1996
Resolved
PROVIDE A WARNING STATEMENT FOR MANUEVERING FACT SHEET._x001C_ 33 CFR 164.35(g)
Fire Fighting
Issued 22 March 1996
Resolved
CONDUCT PERMANENT REPAIRS TO DETERIORATED FUEL TANK VENT PIPING LOCATED PORT SIDE MAIN DECK AFT OF #2 CARGO HOLD._x001C_
Lifesaving
Issued 22 March 1996
Resolved
PROVIDE WEAK LINKS TO THE LIFERAFT PAINTERS TO ALLOW THE INFLATED LIFERAFT_x001C_TO BRAKE FREE OF A SINKING SHIP. SOLAS 74 (AMENDED) III/26.3/38.6
Lifesaving
Issued 22 March 1996
Resolved
PROVIDE ONBOARD VESSEL TRAINING MANUAL FOR LIFESAVING APPLIANCES. SOLAS 74_x001C_(AMENDED) III/18.2/51_x001C_
Fire Fighting
Issued 22 March 1996
Resolved
PROVIDE ONBOARD VESSEL INSTRUCTIONS FOR MAINTENANCE AND OPERATION OF ALL_x001C_ INSTALLATIONS/ EQUIPMENT FOR FIGHTING AND CONTAINMENT OF FIRE. SOLAS 74_x001C_ (AMENDED) II-2/20
Lifesaving
Issued 22 March 1996
Resolved
REMOVE EXCESS OIL ON THE DECK IN THE FORWARD BOSN HOLD.
Fire Fighting
Issued 22 March 1996
Resolved
RENEW AS ORIGINAL DETERIORATED FIRE MAIN PIPING LOCATED PORT SIDE ON THE FOCSEL IN WAY OF THE FIRE HYDRANT VALVE. SOLAS 74 (AMENDED) II-2/21
Construction/Loadline
Issued 22 March 1996
Resolved
RENEW AS ORIGINAL DETERIORATED DIRTY OIL PIPING LOCATED IN THE ENGINE ROOM FWD LOWER LEVEL STBD SIDE OF WATERTIGHT DOOR.
Engineering
Issued 22 March 1996
Resolved
PROVE TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD INSPECTOR SATISFACTORY OPERATION OF THE OILY WATER SEPERATOR
Lifesaving
Issued 22 March 1996
Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER SUPPLY PIPE TO #1 DISTILLER PUMP LOCATED IN THE ENGINE ROOM LOWER LEVEL STBD SIDE.
Fire Fighting
Issued 22 March 1996
Resolved
RENEW/ REPAIR INOPERABLE/ DETERIORATED NATURAL VENTILATION DUCT/ CLOSURE_x001C_ LOCATED STARBOARD SIDE AFT ON THE MAIN DECK HOUSE. SOLAS 60 II/47(a)
Fire Fighting
Issued 22 March 1996
Resolved
UPDATE FIRE CONTROL PLAN IN ACCORDENCE WITH SOLAS 74 AMENDED.
Construction/Loadline
Issued 22 March 1996
Resolved
RENEW/ REPAIR INOPERABLE ACCESS HATCH TO GALLEY AREA LOCATED STARBOARD SIDEON THE MAIN DECK._x001C_
Fire Fighting
Issued 22 March 1996
Resolved
RENEW MISSING FIRE HOSE AND NOZZLE TO FIRE STATION LOCATED STARBOARD SIDE_x001C_ ON THE NAIN DECK HOUSE. SOLAS 74 (AMENDED) II-2/21
Fire Fighting
Issued 22 March 1996
Resolved
RENEW AS ORIGINAL DETERIORATED HOLED FIRE MAIN PIPING LOCATED AFT ON THE #_x001C_4 CARGO HOLD PORT SIDE. SOLAS 74 (AMENDED) II-2/21
Fire Fighting
Issued 22 March 1996
Resolved
RENEW AS ORIGINAL DETERIORATED FIRE MAIN PIPING LOCATED INBOARD OF THE _x001C_ PAINT LOCKER ACCESS DOOR ON THE MAIN DECK FORWARD. SOLAS 74 (AMENDED)_x001C_ II-2/21
Accommodation/Occupational Safety
Issued 22 March 1996
Resolved
RENEW AS ORIGINAL DETERIORATED SAFETY RAILING LOCATED STARBOARD SIDE ON THEFOCSLE.
Accommodation/Occupational Safety
Issued 22 March 1996
Resolved
RENEW/ REPAIR BROKEN HAND RAIL FOR LADDER LOCATED AFT STARBOARD SIDE OF THEMAIN DECK HOUSE ON THE MAIN DECK.
Fire Fighting
Issued 22 March 1996
Resolved
RENEW/ REPAIR INOPERABLE VENTILATION CLOSURE LOCATED PORT SIDE ON THE AFT_x001C_ DECK HOUSE. SOLAS 60 II/47(a)
Fire Fighting
Issued 22 March 1996
Resolved
RENEW/ REPAIR INOPERABLE FIRE HYDRANT VALVE LOCATED AT THE STEERING GEAR_x001C_ ROOM ENTRANCE. SOLAS 74 (AMENDED) II-2/21
Electrical
Issued 22 March 1996
Resolved
RENEW MISSING LIGHTS IN CO2 ACTIVATION ROOM LOCATED PORT SIDE ON THE AFT DECK HOUSE.
Construction/Loadline
Issued 22 March 1996
Resolved
RENEW AS ORIGINAL DETERIORATED WATER TIGHT HATCH LOCATED PORT SIDE ON THE _x001C_POOP DECK. SOLAS 60 II/17(a)
Lifesaving
Issued 9 December 1994
Resolved
PRIOR TO DEPARTURE PORT OF HOUSTON PROCURE AND INSTALL (4) FOUR WEAK LINKS ON THE FOUR AFT INFLATABLE LIFERAFTS AS REQUIRED BY SOLAS 74 CHAPTER III REG 15.
Navigation
Issued 9 December 1994
Resolved
PRIOR TO NEXT U.S. VOYAGE UPDATE/CORRECT CHARTS TO CURRENT CORRCTIONS. SOLAS 74 CHAPTER V REG. 20
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.