MAURY USCG vessel records Sign in
← All vessels

SEA LION

SEA LION is a 1993 freight ship. The Coast Guard has recorded 26 inspections since 1995, most recently in January 2011, along with 21 deficiencies — 2 with no resolution recorded — and 4 operational controls.

Records from 1995 to 2011. Most recent: inspection, 31 January 2011.

Built
1993
Last inspected
31 January 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9050101 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
395638
Flag
ISLE OF MAN
—
Maury page id
psix-395638

Inspections, by type

…with no type recorded18
Years with a record 12 calendar years (1995–2011)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it2815 - Convention (Subpart B), Gross Ton
1532 - Convention (Subpart B), Net Ton
4110 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 26

31 January 2011 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3936127
31 January 2011 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3936298
25 June 2007 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2991480
20 June 2007 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2968720
6 March 2007 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2882483
10 January 2007 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2850854
20 June 2006 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2685849
14 September 2005 Ballast Water Examination · NPV Safety Exam · ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2492558
21 March 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2316059
24 November 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2247281
23 October 2004 NPV Safety Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2226645
18 August 2004 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2170074
20 November 2003 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1951473
19 November 2003 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1951615
29 October 2003 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1938381
24 April 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 277191
24 April 2000 Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 1496634
11 March 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 426158
26 February 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 413163
11 September 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 481272
28 October 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 396688
3 June 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 391770
11 December 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 385899
20 November 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 385088
19 November 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 98260
24 September 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 383037

Deficiency record · 21

Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 31 January 2011 No resolution recorded
Top rail on port side railing fractured presenting safety hazard to crew. Fractured railing located near port forward crane.
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Electrical › Lighting (service) › Lighting Fixture
Issued 31 January 2011 No resolution recorded
Vessel is carrying explosive cargo. Vessel has 3 crached deck light lenses on starboard side and two electrical outlets on port side without electrical covers. Master of vessel has deenergized electrical circuit restricting potential ignition sources.
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 10 January 2007 Resolved
During operational test of steering gear, emergency steering, the rudder angle indicators on the port and starboard bridge wings showed 10 degrees while the indicators on the bridge and the gear itself showed 15 degrees, repair prior to departure from port to satisfaction of administration.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2007
Resolution: Steering gear now operates properly to the satisfaction of the administration.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 10 January 2007 Resolved
Fire door in the main vertical zone, upper deck to poop deck, will not close properly. Repair prior to departure to satisfaction of administration.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2007
Resolution: The fire door now closes properly to the satisfaction of the administration.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 10 January 2007 Resolved
Man overboard boat/rescue boat could not be launched within required time. To satisfaction of the administration.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2007
Resolution: The rescue boat can now be launched in the required time to the satisfaction of the administration.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Discharge Hose/Tube
Issued 10 January 2007 Resolved
Dry powder extinguisher in engine room hose worn beyond usage. Replace hose. To satisfaction of administration.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2007
Resolution: The dry powder hose has been replaced to the satisfaction of the administration.
Electrical › Electric Generation Source (service) › Generator
Issued 10 January 2007 Resolved
The ships number 3 generator is not operational. Repair prior to departure to the satisfaction of the administration.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2007
Resolution: The ships number 3 generator is now operational to the satisfaction of the administration.
Construction/Loadline › Markings › Load Line Assigning Authority Mark
Issued 20 November 2003 Resolved
Permantly affix class society designation on plimsole mark port and stbd sides of vessel where "BV" is painted over welded "DL" (Loadline convention 1966)
Due 31 December 2003
Resolved 18 August 2004
Fire Fighting › Means of Escape › Doorways
Issued 20 November 2003 Resolved
Prove proper operation of fire door latch on engine room escape stbd side of vessel forward of CO2 room.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 November 2003
Resolution: Class report recieved, approved repairs.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 8 November 2003 Resolved
LIFELINES ON LIFEBUOYS ON PORT AND STBD SIDE POOPDECK NEED TO BE REPLACED IAW SOLAS 74/78 III/20.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2003
Resolution: RECIEVED FAX INVOICE REPORT FOR MARINE LINE, ALL SAT.
Construction/Loadline › Markings
Issued 8 November 2003 Resolved
LOADLINE MARKINGS ON BOTH SIDE OF THE HULL MUST BE MARKED IAW LOADLINE CERTIFICATE, ILCC REG. 6 AND 7. MUST BE COMPLETED PRIOR TO NEXT U.S. PORT TO THE SATISFACTION OF VESSEL'S CLASS SOCIETY. LEGACY COMPONENT DESC: Load Line Mark
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 20 November 2003
Resolution: Not resolved, resolution date pushed back to 31Dec2003.
Accommodation/Occupational Safety › Occupational Safety
Issued 8 November 2003 Resolved
DECK OUTSIDE OF THE CO2 ROOM MUST BE SATISFACTORY APPROVED BY THE VESSEL'S CLASS SOCIETY IAW ILCC REG. 1. MUST BE COMPLETED PRIOR TO NEXT U.S PORT TO THE SATISFACTION OF THE VESSEL'S CLASS SOCIETY. LEGACY COMPONENT DESC: DECK OUTSIDE OF CO2 ROOM
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Resolved 20 November 2003
Resolution: Deck inspected by class society, approved.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 8 November 2003 Resolved
DEAD END WIRING IN THE CO2 ROOM MUST BE SATISFACTORY APPROVED BY THE VESSEL'S CLASS SOCIETY IAW SOLAS 74/78 II-1/40.1.3. MUST BE COMPLETED PRIOR TO NEXT U.S. PORT TO THE SATISFACTION OF THE VESSEL'S CLASS SOCIETY. LEGACY COMPONENT DESC: DEAD END WIRING
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 20 November 2003
Resolution: Inspected to the satisfaction of class.
Electrical › Lighting (service)
Issued 8 November 2003 Resolved
FORWARD #1 AND #2 DECK LIGHTS, CASINGS/ENCLOSURES, STARBOARD SIDE NEED TO BE REPLACED IAW SOLAS 74/78 II-1/40.1.3. MUST BE COMPLETED PRIOR TO NEXT U.S PORT TO THE SATISFACTION OF USCG. LEGACY COMPONENT DESC: DECK LIGHT CASINGS
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 20 November 2003
Resolution: Wiring condition resolved to the satisfaction of inspectors.
Pollution Prevention/Response › Prevention Equipment
Issued 8 November 2003 Resolved
PROVIDE USCG APPROVAL CERTIFICATE FOR MARINE SANITATION DEVICE IAW 33CFR 159.12(a). MUST BE COMPLETED PRIOR TO NEXT U.S. PORT TO THE SATISFACTION OF USCG. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 20 November 2003
Resolution: Placard onboard.
Documentation › Markings/Placards
Issued 8 November 2003 Resolved
POST OIL POLLUTION PLACARD IAW 33 CFR 155.450. MUST BE COMPLETED PRIOR TO NEXT U.S. PORT TO THE SATISFACTION OF USCG. LEGACY COMPONENT DESC: Oil Discharge Placard
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 20 November 2003
Resolution: Placard onboard and posted.
Documentation › Markings/Placards
Issued 8 November 2003 Resolved
POST MARPOL V PLACARD IAW MARPOL AX. V/9. MUST BE COMPLETED PRIOR TO NEXT U.S PORT TO THE SATISFACTION OF USCG. LEGACY COMPONENT DESC: MARPOL V PLACARD
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 20 November 2003
Resolution: Placard onboard and posted.
Documentation › Certificates/Documents
Issued 8 November 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 20 November 2003
Resolution: Inspected to the satisfaction of USCG
Navigation
Issued 3 June 1996 Resolved
ADMIRATY CHART #69 WITH SUPPLEMENTS MUST BE UPDATED AND ADMIRITY LIGHT LISTVOLUME J NEED TO ENTER CORRECTIONS.
Condition: Unknown
Due 3 June 1996
Resolved 4 June 1996
Navigation
Issued 3 June 1996 Resolved
VESSEL WAS MISSING A MANEVERING FACT SHEET.
Condition: Unknown
Due 28 October 1996
Resolved 28 October 1996
Documentation
Issued 24 September 1995 Resolved
PROVIDE ON BOARD A WASTE MANAGEMENT PLAN._x001C_ _x001C_ _x001C_ MARPOL V
Condition: Unknown
Due 13 December 1995
Resolved 13 December 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.