Records from 1993 to 2007. Most recent: inspection, 14 December 2007.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
14 December 2007
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3115934
27 April 2004
COI Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2052766
28 October 2003
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1939551
15 May 2002
Re-Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1616972
27 June 2001
COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1376757
27 September 2000
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1053927
3 August 2000
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 821226
20 May 2000
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1445673
1 June 1999
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1397281
23 April 1999
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 790761
23 June 1998
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1460209
21 May 1998
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1446659
12 June 1997
Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1437311
24 June 1996
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 857111
4 June 1996
Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1446374
5 March 1996
Hull Examination · Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1394493
4 October 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 108499
6 June 1995
Hull Examination · Plan Review "T" Boat · COI Inspection · Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1360137
6 October 1994
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 865297
14 January 1994
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1161206
30 September 1993
Initial Certification · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1158193
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 27 April 2004
Resolved
Provide proof of valid state vessel registration.
Action required: 705 - Other - as specified
Due 30 July 2004
Resolved 10 September 2004
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 27 April 2004
Resolved
Provide current excerpts from navigation safety publications required by 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 30 July 2004
Resolved 10 September 2004
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 27 April 2004
Resolved
Provide 6 Adult Type I PFDs approved under 46 CFR 160.055.
Action required: 705 - Other - as specified
Due 30 July 2004
Resolved 10 September 2004
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 April 2004
Resolved
Provide an electric floating light approved under 46 CFR 161.010 fitted with 3 foot lanyard and corrosion resistant clip for life ring buoy as required by 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 30 July 2004
Resolved 10 September 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 April 2004
Resolved
Provide first aid kit approved under 46 CFR 160.041 (or kit with equivalent contents) as required by 46 CFR 184.710.
Action required: 705 - Other - as specified
Due 30 July 2004
Resolved 10 September 2004
Fire Fighting › Fire Bucket › Quantity
Issued 27 April 2004
Resolved
Provide two additional, suitable fire buckets with lanyards and markings as required by 46 CFR 181.610.
Action required: 705 - Other - as specified
Due 30 July 2004
Resolved 10 September 2004
Operations/Management › Drills/Instruction › Not Conducted
Issued 27 April 2004
Resolved
Perform satisfactory Fire, Man Overboard and Abandon Ship drills as required by 46 CFR Part 176, in the presence of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 30 July 2004
Resolved 10 September 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 27 April 2004
Resolved
Provide one B-II portable fire extinguisher approved under 46 CFR 162.028 and locate just outside machinery area as required by 46 CFR 181.500(a).
Action required: 705 - Other - as specified
Due 30 July 2004
Resolved 10 September 2004
Construction/Loadline › Hull › Hull Plating
Issued 27 April 2004
Resolved
Perform tighness test of port pontoon hull repair in the presence of the attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 July 2004
Resolved 10 September 2004
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 27 April 2004
Resolved
Install deck rail on bow of vessel that meet the requirements of 46 CFR 177.900.
Action required: 705 - Other - as specified
Due 30 July 2004
Resolved 10 September 2004
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 October 2003
Resolved
Vessel overdue for inspection as of 27 SEP 03. Vessel is out of service and O/O submitted letter stating such and will be brought back into service MAR/APR 04. Sent O/O deactivation letter signed by CID MOBMS, letter dated 28 OCT 03.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2004
Resolved 10 September 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 27 June 2001
Resolved
INSTALL RAIL COURSES, BARS, SLATS, OR MESH ON DECK RAIL COMPLYING WITH 46 CFR 177.900 PRIOR TO 27 JULY 01. LEGACY COMPONENT DESC: Deck Rail
Condition: Unknown
Due 27 July 2001
Resolved 29 October 2001
Resolution: Proper installation of mesh on deck rail was completed.
Navigation
Issued 3 August 2000
Resolved
PROVIDE CHARTS AND PUBS AS REQUIRED BY 46 CFR 184.420.
Condition: Unknown
Due 3 August 2000
Resolved 3 August 2000
Accommodation/Occupational Safety
Issued 3 August 2000
Resolved
PROVIDE RAIL COURSES AS REQUIRED BY 46 CFR 177.900.
Condition: Unknown
Due 3 August 2000
Resolved 3 August 2000
Lifesaving
Issued 3 August 2000
Resolved
PROVIDE U/V RESISTANT LINE FOR THE LIFE RING.
Condition: Unknown
Due 3 August 2000
Resolved 3 August 2000
Engineering
Issued 12 June 1997
Resolved
RENEW FUEL SUPPLY HOSE FROM PORTABLE FUEL TANK TO OUTBOARD ENGINE.
Condition: Unknown
Due 28 June 1997
Resolved 28 October 1997
Accommodation/Occupational Safety
Issued 4 June 1996
Resolved
PROVIDE A PROPER HEAD FACILITY FOR PASSENGERS.
Condition: Unknown
Due 4 July 1996
Resolved 22 July 1996
Fire Fighting
Issued 4 June 1996
Resolved
PROVIDE AND INSTALL SAFETY WIRE FOR FIRE EXTINGUISHER PIN.
Condition: Unknown
Due 4 July 1996
Resolved 22 July 1996
Navigation
Issued 4 June 1996
Resolved
PROVE PROPER OPERATION OF THE VHF RADIO.
Condition: Unknown
Due 4 July 1996
Resolved 22 July 1996
Lifesaving
Issued 4 June 1996
Resolved
PROVIDE 3 EACH NON-EXPIRED ORANGE SMOKES AND 3 EACH RED FLARES.
Condition: Unknown
Due 4 July 1996
Resolved 22 July 1996
Documentation
Issued 4 June 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 July 1996
Resolved 22 July 1996
Lifesaving
Issued 30 September 1993
Resolved
STENCIL VESSEL NAME "FL9262HT" ON ALL LIFE PRESERVERS AND ON RING BUOY.
Condition: Unknown
Due 30 September 1993
Resolved 30 September 1993