Records from 1993 to 2025. Most recent: inspection, 19 November 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 35
19 November 2025
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8250019
5 December 2024
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8013597
5 October 2023
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7799796
20 September 2022
COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7531773
22 September 2021
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7311507
24 September 2020
Examination of Repairs · Annual Inspection · Administrative Inspection · Drydock Exam · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7069998
26 September 2019
Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6814721
19 September 2018
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6520121
19 September 2018
Drydock Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6544913
15 September 2017
DAPI Audit · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6267106
15 September 2016
Hull Examination · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5995208
20 October 2015
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5747110
27 August 2015
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5227553
17 October 2014
Annual Inspection · DAPI Audit · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5008358
27 September 2011
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4156488
16 September 2010
Hull Examination · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3845425
27 October 2008
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3352358
15 October 2007
COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3080534
18 October 2005
Annual Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2568359
24 November 2004
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2249141
6 November 2003
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1943374
11 September 2003
In-Service Inspection · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1873835
18 October 2002
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1695942
16 August 2001
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1448332
22 September 2000
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1424990
18 August 1999
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1415238
24 March 1999
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1375847
19 November 1998
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1442802
9 February 1998
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1110033
15 September 1997
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1455522
1 April 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1100772
19 September 1996
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1463991
12 September 1995
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1079189
6 October 1994
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1175749
30 September 1993
COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 830072
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 September 2019
Resolved
USCG Type A1, A2, B1, or B2 flexible hose may be accepted in accordance with 33 CFR part 183, subpart J.
Replace unapproved flex hose in accordance with SAE J1527.
46 CFR 182.720 (e)(3)(v)(c)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 10 October 2019
Resolved 10 October 2019
Resolution: Owner/Operator replaced flex hose IAW SAE J1527.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 September 2019
Resolved
Ring life buoy must be fitted with a lifeline.
Replace unapproved lifeline with 5/16" UV protected line.
46 CFR 180.70 (c)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 10 October 2019
Resolved 10 October 2019
Resolution: Owner / Operator replaced ring buoy lifeline.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 September 2019
Resolved
A positive shutoff valve is installed at the hull penetration for submersible electric bilge pump. O/O needs to install shutoff valve at hull penetration IAW 46 CFR 182.520(e)(6).
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 10 October 2019
Resolved 10 October 2019
Resolution: Owner/Operatorinstalled valve at the hull penetration for submersible electric bilge pump.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 September 2018
Resolved
The containers in which they are stowed shall be marked "Life Preservers" and with the number contained therein, in at least 1-inch high letters and figures.
46CFR185.30-10
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 September 2018
Resolved 19 September 2018
Resolution: Owner labeled each container that stores life jackets with the correct number and size.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 15 September 2017
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2017
Resolved 14 December 2018
Resolution: Called O/O to resolve issue. All designated masters in company have conducted drills w/ attending marine inspectors to comply with local master only policy.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 27 September 2011
Resolved
Found rotten wood in way of seating, supports, fwd step and helm stations IAW 46CFR176.802.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2011
Resolution: Replaced in kind to satisfaction of Marine Inspector
Construction/Loadline › Hull › Bottom Plating
Issued 16 September 2010
Resolved
Make permanent repair to puncture in hull bottom located port side 2/3 aft of bow. Provide repair proposal. Repairs to original construction to be completed per chapter 6 NVIC 8-87. Scarf area of repair 12 to 1 per hull thickness.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2010
Construction/Loadline › Hull
Issued 11 September 2003
Resolved
Fiberglass blistering and worn through first layer of fiberglass. Need to strip and gelcoat entire bottom.
Action required: 705 - Other - as specified
Resolved 10 November 2003
Lifesaving
Issued 16 August 2001
Resolved
Replace seven adult PFD's and one child PFD, vessel's carring capacity is reduced to 10 persons until PFD's are replaced.
Condition: Unknown
Due 16 August 2001
Resolved 11 September 2003