The 11 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for OAKTREE, retrieved 18 September 2026. mauryrecords.com/v/psix-396031.html
Documentation record
Tonnage as PSIX records it28277 - Regulatory (Subpart C or D), Gross Ton 12697 - Regulatory (Subpart C or D), Net Ton 44999 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 11
1 April 2022Deficiency Check · Administrative Inspection
Action required: 705 - Other - as specified
Due 26 March 2007
Resolved 20 March 2007
Resolution: The OWS was replaced with a new OWS 15PPM Equipment (Decma Hamburg Gmbh OMD-2005).
Deck/Cargo › Vapor Control Systems › Vapor Recovery Unit
Issued 13 March 2007Resolved
Vapor collection system piping not labeled "vapor" on all pipes and all flanges missing or inadequate 1' studs at top of flange.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 March 2007
Resolution: VCS piping were labeled "VAPOR" on all pipes and all flanges missing 1'' stud at top of flange fitted.
Documentation
Issued 1 July 2000Resolved
Provide geographic spicfic annex that includes Pago Pago in the COTP Honolulu zone.
Condition: Unknown
Due 1 August 2000
Resolved 1 April 2022
Resolution: Vessel was discovered during a data pull for old open deficiencies. Although the vessel is still listed as active in MISLE, multiple sources consistently state that the vessel was scrapped in 2019, rendering any open deficiencies moot.
Deck/Cargo
Issued 2 February 1997Resolved
Vessel's cargo containment plugs on deck did had a non-mechanical means _x001C_of closing.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Lifesaving
Issued 13 December 1994Resolved
REMOVE OR RESTOW ALL THE CHEMICALS/LUBRICATING LOCATED IN AFT STEERING. BOTH LUBRICATING FLUIDS AND CHEMICALS ARE STORED THERE WITH LITTLE OR NO SEGREATION BETWEEN CANS OR DRUMS.
Condition: Unknown
Due 13 December 1994
Resolved 13 December 1994
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.