Records from 1989 to 1997. Most recent: inspection, 28 May 1997.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 8
28 May 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 404024
17 June 1996
Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 392311
18 October 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 166008
8 July 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 380407
9 June 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 379328
13 March 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 532334
7 February 1990
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 335265
14 August 1989
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 332121
Engineering
Issued 28 May 1997
Resolved
33CFR155.320 - MISSING CONTAINMENT WITH 1/2 BARREL CAPACITY AROUND ALL FUELTANK VENTS WITH MECHANICAL MEANS OF CLOSING WITHIN COMBING. MUST MEET THISREQUIREMENT OR PROVIDE A PORTABLE CONTAINMENT.
Condition: Unknown
Due 1 June 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 9 June 1995
Resolved
PROVIDE NON-CONDUCTIVE MATTING IN FRONT OF SHIP SERVICE GENERATOR SWITCHBOARDS. PROVIDE COAST GUARD WITH CLASS REPORT SOLAS REG II-1 REG 43
Condition: Unknown
Due 8 July 1995
Resolved 8 July 1995
Lifesaving
Issued 9 June 1995
Resolved
PROVIDE ONBOARD INSTRUCTIONS FOR ONBOARD MIANTAINENCE OF LIFESAVING EQUIPMENT. SOLAS III REG. 19 AND 52. PROVIDE LOCAL COAST GUARD WITH COPY OFINVOICE.
Condition: Unknown
Due 8 July 1995
Resolved 8 July 1995
Navigation
Issued 9 June 1995
Resolved
PROVIDE NON-SLIP SURFACE FOR STEERING GEAR COMPARTMENT DECK. PROVIDE COAST GUARD WITH CLASS REPORT. SOLAS REG. II-1 29
Condition: Unknown
Due 8 July 1995
Resolved 8 July 1995
Deck/Cargo
Issued 9 June 1995
Resolved
REPAIR SMALL HYDRAULIC FLUID LEAK ON STARBOARD SIDE HYDRAULIC RAM FOR HATCHCOVERS.
Condition: Unknown
Due 8 July 1995
Resolved 8 July 1995
Construction/Loadline
Issued 9 June 1995
Resolved
RENEW WASTED AREAS OF AIR VENT PIPING GOOSENECK VENTS ON STARBOARD SIDE BRIDGE WING. PROVIDE COAST GUARD WITH CLASS REPORT.
Condition: Unknown
Due 8 July 1995
Resolved 8 July 1995
Documentation
Issued 9 June 1995
Resolved
ENSURE ALL CREWMEN AND OFFICERS HAVE VALID MEDICAL EXAMINATION CERTIFICATES. PROVIDE COAST GUARD WITH COPY. ILO 147
Condition: Unknown
Due 8 July 1995
Resolved 8 July 1995
Engineering
Issued 9 June 1995
Resolved
PROVIDE CONTAINMENT OF AT LEAST 1/2 BARREL CAPACITY FOR EACH FUEL OIL AND BULK LUBRICATING OIL TANK VENT, OVERFLOW AND FILL PIPE. AS REQUIRED BY 33 CFR 155.320.
Condition: Unknown
Due 8 July 1995
Resolved 8 July 1995
Engineering
Issued 9 June 1995
Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF OILY WATER SEPARATOR TO SATISFACTION OF CLASS SOCIETY. PROVIDE LOCAL COAST GUARD WITH COPY OF CLASSREPORT.
Condition: Unknown
Due 8 July 1995
Resolved 8 July 1995
Documentation
Issued 7 February 1990
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 23 June 1995
Resolved 23 June 1995
Documentation
Issued 7 February 1990
Resolved
49CFR176.30(A)(3) IMPROPER SHIPPING NAME FOR HIGH EXPLOSIVE. ITEMS #1-3, 5-10, & 12-17 ON DCM ARE IMPROPERLY IDENTIFIED BY TECHNICAL CHEMICAL NAMES.
Condition: Unknown
Due 23 June 1995
Resolved 23 June 1995
Documentation
Issued 7 February 1990
Resolved
49CFR176.24 IMPROPER SHIPPING NAMES ON SHIPPING PAPERS FOR ITEMS IDENTIFIEDWITH P-1 THRU P-3, P-7, P-9, P-11, P-13 THRU P-22, P-25, P-26, P-28, P-31, P-32.
Condition: Unknown
Due 23 June 1995
Resolved 23 June 1995
Documentation
Issued 7 February 1990
Resolved
49CFR173.51 TRANSPORTATION OF EXPLOSIVES WHICH HAVE NOT BEEN CLASSED AND APPROVED BY DOT AS REQUIRED BY 49CFR1763.86 ONTO THE NAVIGABLE WATERS OF THE UNITED STATES, IDENTIFIED AS P-4,5,6,8,12,23,24,29, AND P-30-A4 AND P-30-CH6 ON THE SHIPPING PAPERS.
Condition: Unknown
Due 23 June 1995
Resolved 23 June 1995
Deck/Cargo
Issued 7 February 1990
Resolved
49CFR172.101(7)(A) EXPLOSIVE "A" & "B" HAZARDOUS MATERIALS WERE NOT STOWED IN A EXPLOSIVE MAGAZINE CONSTRUCTED AS REQUIRED BY 49CFR176.138 & 49CFR176.141
Condition: Unknown
Due 23 June 1995
Resolved 23 June 1995
Documentation
Issued 7 February 1990
Resolved
49CFR176.83 TABLE II NITROCELLUOSE A FLAMMABLE SOLID IS NOT SEPARATED LONGITUDINALLY BY AN INTERVENING COMPLETE CARGO COMPARTMENT OR HOLD OR ENGINE ROOM FROM 49 CLASS "A" EXPLOSIVE COMMODOTIES ON BOARD THE VESSEL.
Condition: Unknown
Due 23 June 1995
Resolved 23 June 1995
Documentation
Issued 7 February 1990
Resolved
49CFR176.39 THE CARGO WAS NOT INSPECTED AS ON A DAILY BASIS AND ENTRY MADE ONTO THE VESSELS LOG AS TO THE RESULTS OF THE INSPECTION.
Condition: Unknown
Due 23 June 1995
Resolved 23 June 1995
Documentation
Issued 7 February 1990
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 23 June 1995
Resolved 23 June 1995