MAURY USCG vessel records Sign in
← All vessels

BRILLANTE VIRTUOSO

BRILLANTE VIRTUOSO is a 1992 tank ship. The Coast Guard has recorded 28 inspections since 1998, most recently in July 2008, along with 23 deficiencies and 3 operational controls.

Records from 1998 to 2008. Most recent: inspection, 7 July 2008.

Built
1992
Last inspected
7 July 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9014822 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
396498
Flag
MARSHALL ISLANDS
—
Maury page id
psix-396498

Inspections, by type

…with no type recorded14
Years with a record 10 calendar years (1998–2008)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it80569 - Convention (Subpart B), Gross Ton
45730 - Convention (Subpart B), Net Ton
149599 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 28

7 July 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3260532
24 April 2008 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3191425
24 April 2008 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3194542
29 October 2007 Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3089240
16 October 2007 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3080774
22 September 2007 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3063458
5 January 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2850935
19 November 2005 ISPS III Exam · COC-TVE Renew
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2535027
10 December 2004 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2257092
2 November 2004 ISPS I Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2233011
26 October 2004 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2229484
25 October 2004 COC-TVE Renew
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2225571
18 September 2003 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1910894
4 December 2002 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1714139
3 December 2002 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1713793
30 May 2002 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1623224
1 November 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 295016
3 October 2001 Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1073688
5 June 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 290410
27 March 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 288534
27 September 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 282614
2 July 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 279397
30 August 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 431872
30 August 1999 Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1030751
27 March 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 533312
30 October 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 109599
5 August 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 418861
5 August 1998 Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 796098

Deficiency record · 23

Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 3 November 2007 Resolved
Noted that the closure for the incinerator is broken. Make repairs to the incinerator door handle to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 April 2008
Resolution: Received Class survey report dated 24 Nov 07 satisfying imposed requirement. The incinerator door handle was repaired to the satisfaction of attending Class surveyor. The deficiency has been rectified.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 3 November 2007 Resolved
Noted that the OWS three way valve did not actuate when calibration fluid was introduced to the sensor. Prove proper operation of the OWS three way valve to the satisfaction of class. Until rectified, retain all oily water on board or discharge to approved reception facility.
Action required: 705 - Other - as specified
Due 3 December 2007
Resolved 24 April 2008
Resolution: Received Class survey report satisfying imposed requirement. The proper operation of OWS 3-way valve was verified. The operational test was carried out to the satisfaction of attending Class surveyor. The deficiency has been rectified.
Deck/Cargo › Ballast › Pumps
Issued 3 November 2007 Resolved
Noted a pipe patch on suction side of #2 ballast pump. Make permenant repairs to the satisfaction of vessel's classification society.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 April 2008
Resolution: Received Class survey report dated 15 Dec 07 satisfying imposed requirement. A permanent repair was carried out and water leak was eliminated. This repair was carried out to the satisfaction of attending Class surveyor.
Deck/Cargo › Cargo Heating › General
Issued 3 November 2007 Resolved
Noted steam leak on cargo heating line on main deck, starboard side, forward of superstructure. Make permanent repairs to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 April 2008
Resolution: Received Class survey report dated 15 Dec 07 satisfying imposed requirement. A permanent repair was carried out and steam leak was eliminated to the satisfaction of attending Class surveyor. The deficiency has been rectified.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 3 November 2007 Resolved
Found evidence of metal filling compound on deck water seal drain line. Make permanent repairs to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 April 2008
Resolution: Received Class survey report dated 24 Nov 07 satisfying imposed requirement. Permanent repair was carried out to the satisfaction of attending Class surveyor. The deficiency has been rectified.
Engineering › Steam System (main) › Piping
Issued 3 November 2007 Resolved
Found steam leaks at main valve on #1 boiler and flange inboard of incinerator. Repair steam leaks to the satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Due 17 November 2007
Resolved 24 April 2008
Resolution: Received Class survey report dated 24 Nov 07 satisfying imposed requirement. The steam leak was eliminated to the satisfaction of attending Class surveyor. The deficiency has been rectified.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 22 September 2007 Resolved
Make repairs prove proper operation of main engine reversing gear.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2007
Engineering › Compressed Air System (control) › Piping
Issued 22 September 2007 Resolved
Submit completed 2692 for reversing starting incident.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 September 2007
Resolved 27 September 2007
Communications › Radio Communications › Satellite Communications Capability
Issued 19 November 2005 Resolved
GMDSS is not operating properly; it will not transmit. Repair to the satisfaction of class prior to departing next US port (Houston, TX)
Action required: 705 - Other - as specified
Resolved 23 November 2005
Resolution: Received class socity report, GMDSS is working properly.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 25 October 2004 Resolved
Make pumproom available for inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2004
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 25 October 2004 Resolved
Make repairs to soft patches on deck water seal hatchments for water level alarm-water supply line prior to conducting cargo operations in U. S. Waters.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 December 2004
Resolved 10 December 2004
Resolution: Recieved class report stating piping was renewed and tested to satisfaction of ABS Inspector.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 25 October 2004 Resolved
Renew electrical safety mat at engine control room switchboard.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 25 October 2004
Construction/Loadline › Structures › Door
Issued 25 October 2004 Resolved
Make repairs to port and stbd engine control room doors.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 October 2004 Resolved
Renew flexible electrical conduit #1 and #2 auxillary boiler at burner.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 25 October 2004
Engineering › Freshwater System (jacketwater cooling) › Fitting
Issued 25 October 2004 Resolved
Make repairs to main engine jacket water heat exchanger and low temperature heat exchanger--Leaks prior to conducting Cargo operations in U. S. Waters.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 December 2004
Resolved 10 December 2004
Resolution: Recieved class report stating that reducers and inlet pressure guage were renewed and tested to satisfaction of ABS surveyor.
Deck/Cargo › Cargo Heating › General
Issued 25 October 2004 Resolved
Properly install boilers #1 and #2 hand relief gear
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2004
Engineering › Fuel Oil Service System › Filter
Issued 25 October 2004 Resolved
In the purifier room, make repairs to composite boiler fuel oil pumps #1 discharge guage, heater pressure guage, hot filter (ME) control air pr. guage on dryer, MDO transfer pump discharge pr. guage aux boiler pump discharge guage.
Action required: 15 - Rectify deficiencies by next port
Resolved 25 October 2004
Construction/Loadline › Structures › Door
Issued 25 October 2004 Resolved
Replace missing hinge boldt in door from engine room to steering gear room.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 25 October 2004
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 25 October 2004 Resolved
Make permanant repairs to soft patches on bunker line located just forward of pumproom just starboard of centerline. Until repairs are completed area to be monitored during bunkering.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 December 2004
Resolved 6 November 2006
Fire Fighting › Fire Main › Condition
Issued 25 October 2004 Resolved
Make permenant repairs to pinhole leak in firemain located aft of IG room where fire main makes turn around corner proir to conducting cargo operations in U.S. Waters.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 December 2004
Resolved 10 December 2004
Resolution: Recieved class report stating that the piping was renewed and tested to satisfaction of ABS Inspector.
Fire Fighting › Fire Main › Condition
Issued 25 October 2004 Resolved
Make permanent repairs to soft patches located on fire main located in Emergency Generator Alley prior to conducting cargo operations in U. S. Waters.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 December 2004
Resolved 10 December 2004
Resolution: Recieved class report stating that the piping was renewed and tested to satisfaction of ABS Inspector
Fire Fighting › Fire Hydrants › Condition
Issued 25 October 2004 Resolved
#2 and #4 foam monitors to be maintained to allow them to go up and down to their designed limit.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 25 October 2004
Lifesaving
Issued 27 September 2000 Resolved
CREW DID NOT DISPLAY ABILITY TO LOWER LIFEBOAT IN A TIMELY MANNER.
Condition: Unknown
Due 29 December 2000
Resolved 29 December 2000

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.