Records from 1995 to 2008. Most recent: inspection, 26 August 2008.
Inspection history · 25
26 August 2008
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3309169
5 February 2004
Annual Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2000848
3 February 2003
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1739609
15 July 2002
Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1647312
11 June 2002
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1629344
11 June 2002
Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1629365
30 June 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 291516
25 April 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 289441
24 April 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 103463
20 January 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 286189
2 June 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 278675
16 October 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 433812
29 June 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 430210
10 December 1998
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 423467
5 December 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 423395
5 July 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 417674
23 July 1997
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 449411
11 July 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 405700
5 July 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 405466
26 June 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 404961
16 February 1997
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 400906
10 February 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 400083
6 March 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 388192
22 January 1995
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 33707
12 January 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 374073
Personnel › Certificates/Documents/Licenses
Issued 5 February 2004
Resolved
No Flag Endorsement or Documentary Proof from Flag Administration that application has been made for Flag state licenses with required STCW 95 Certificates for the 3rd Mate and 3rd Engineer. Vessel is detained in Accordance with STCW 95 Regulation I/4. Prior to departure proof must be provided. LEGACY COMPONENT DESC: 3RD MATE, 3RD ENGINEER
Action required: 17 - Rectify deficiencies prior to departure
Due 5 February 2004
Resolved 6 February 2004
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 5 February 2004
No resolution recorded
Fuel oil vent containment (port side amidships) wasted and has no means of draining. Repair to the satisfaction of class. (33CFR155.320)
Action required: 705 - Other - as specified
Due 5 March 2004 — due date passed with no resolution recorded
Construction/Loadline › Hull
Issued 5 February 2004
Resolved
Two fractures on bulwark, stbd, amidships iwo cargo hold #3. Repair to
the satisfaction of class. (ICLL 66 ANNEX I/15) LEGACY COMPONENT DESC: Bulwark
Due 5 February 2004
Resolved 6 February 2004
Resolution: Rcv''d Class Report (ABS Representative) dated 06Feb04. Pemanent repair made.
Electrical › Electrical Distribution System (service)
Issued 5 February 2004
Resolved
Forward Electrical Room has standing water and electrical wires on deck leading to electrical boxes. Class to attest to alteration of Electrical Boxes and source of standing water. (SOLAS 74(A) II-I/45.1 LEGACY COMPONENT DESC: Electrical Box
Action required: 705 - Other - as specified
Due 5 February 2004
Resolved 6 February 2004
Resolution: Rcv''d Class Report (ABS Representative).
Fire Fighting › Fire Main
Issued 5 February 2004
Resolved
Fire Main iwo fuel oil tank wasted. Repair/replace to the satisfaction of Class. (SOLAS 74(A) II-2/21 LEGACY COMPONENT DESC: Condition
Action required: 705 - Other - as specified
Due 5 February 2004
Resolved 6 February 2004
Resolution: Rcv''d Class Report (ABS Representative). Permanent repair made.
Engineering › Sea-water System (primary cooling)
Issued 5 February 2004
Resolved
Seawater cooling drain line iwo fuel oil tank wasted. Repair/ replace to the satisfaction of Class. (SOLAS 74(A) II-I/26 LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 5 February 2004
Resolved 6 February 2004
Resolution: Rcv''d Class Report (ABS Representative). Permanent repair made.
Engineering › Sea-water System (primary cooling)
Issued 5 February 2004
Resolved
Seawater cooling pipe for main engine wasted iwo seawater cooling pump. 12 inch pipe with approximately 4inch by 4 inch wastage. Repair/replace to the satisfaction of Class. (SOLAS 74(A) II-I/26) LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 5 February 2004
Resolved 6 February 2004
Resolution: Rcv''d Class Report (ABS Representative). Permanent repairt made.
Engineering › Steam Boiler (propulsion)
Issued 5 February 2004
Resolved
Feedwater pipe for boiler iwo fire pump, stbd side, wasted with numerous soft patches. Repair/ replace to the satisfaction of Class. (SOLAS 74(A) II-I/26) LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 5 February 2004
Resolved 6 February 2004
Resolution: Rcv''d Class Report (ABS Representative). Permanent repair made.
Navigation
Issued 2 June 2000
Resolved
RECORDING DEVICE FOR ECHO DEPTH SOUNDER FOUND INOP. (33 CFR 164.35(i)). MAKE PERMANENT REPAIRS PRIOR TO DEPARTURE OF PORT.
Condition: Unknown
Due 23 January 2001
Resolved 23 January 2001
Deck/Cargo
Issued 2 June 2000
Resolved
BOLTS FOR AFT CARGO RAMP AND FORWARD MOORING WINCHES SHOW EVIDENCE OF WASTAGE (SOLAS 74 AMENDED REG I/11). CLASS SOCIETY TO PROVIDE REPORT ADDRESSING CONDITION.
Condition: Unknown
Due 5 June 2000
Resolved 7 June 2000
Documentation
Issued 2 June 2000
Resolved
SAFETY EQUIPMENT CERTIFICATE EXPIRED ON 30MAY00 (SOLAS 74 AMENDED, REG I/14).
Condition: Unknown
Due 5 June 2000
Resolved 7 June 2000
Engineering
Issued 11 July 1997
Resolved
TURBO CHARGER ROTOR BLOWER BROKEN AND AHSORE FOR REPAIR. CONDITION OF CLASS (ABS) #HS22293 CONSIDERS MAIN ENGINE SATISFACTORY FOR REDUCED OPERATIONS.
Condition: Unknown
Due 25 July 1997
Resolved 25 July 1997
Engineering
Issued 5 July 1997
Resolved
Incomplete oil transfer procedures. 33CFR155.720
Condition: Unknown
Due 9 July 1997
Resolved 15 July 1997
Construction/Loadline
Issued 5 July 1997
Resolved
Excessive accumulation of bilge oil. 33CFR155.330
Condition: Unknown
Due 10 July 1997
Resolved 15 July 1997
Engineering
Issued 5 July 1997
Resolved
Inoperative turbo-charger. SOLAS 74/78 I/11
Condition: Unknown
Due 9 August 1997
Resolved 16 July 1997
Documentation
Issued 26 June 1997
Resolved
VESSEL DID NOT HAVE A WASTE MANAGEMENT PLAN AS REQUIRED BY MARPOL ANNEX V REG 4.2.
Condition: Unknown
Due 25 July 1997
Resolved 25 July 1997
Deck/Cargo
Issued 26 June 1997
Resolved
VESSEL HAD WASTED GOOSENECK VENT PIPES ON FOCSLE. REPAIR REQUIRED AT NEXT DRYDOCK. ILLC 66 ANNEX 1 REG. 20
Condition: Unknown
Due 9 July 1998
Resolved 9 July 1998
Navigation
Issued 26 June 1997
Resolved
VESSEL'S COAST GUARD LIGHT LIST WAS OUTDATED AS REQUIRED BY 33 CFR 164.33 (a)(2)(ii).
Condition: Unknown
Due 25 July 1997
Resolved 25 July 1997
Navigation
Issued 26 June 1997
Resolved
VESSELS U.S. COAST PILOT WAS OUTDATE AS REQUIRED BY 33 CFR 164.33 (a)(2)(i).
Condition: Unknown
Due 25 July 1997
Resolved 25 July 1997
Construction/Loadline
Issued 26 June 1997
Resolved
VESSEL REUIRED TO REPLACE GASKET MATERIAL ON ALL EXTERIOR WATERTIGHT DOORS BY NEXT SCHEDULED DRYDOCK. ILLC 66 ANNEX 1 REG. 12.
Condition: Unknown
Due 9 July 1998
Resolved 9 July 1998
Documentation
Issued 10 February 1997
Resolved
PROVIDE A THIRD MATE OR A FLAG STATEMENT ALLOWING THE VESSEL TO SAIL SHORT.SOLAS 74-V-13.
Condition: Unknown
Due 10 February 1997
Resolved 11 February 1997