MAURY USCG vessel records Sign in
← All vessels

NOISELESS

NOISELESS is a 1992 tank ship. The Coast Guard has recorded 24 inspections since 1998, most recently in May 2007, along with 17 deficiencies and 2 operational controls.

Records from 1998 to 2007. Most recent: inspection, 21 May 2007.

Built
1992
Last inspected
21 May 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9014834 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
396704
Flag
MARSHALL ISLANDS
—
Maury page id
psix-396704

Inspections, by type

…with no type recorded19
Years with a record 9 calendar years (1998–2007)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it80569 - Regulatory (Subpart C or D), Gross Ton
45730 - Regulatory (Subpart C or D), Net Ton
149544 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

21 May 2007 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2936400
1 May 2007 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2932916
30 April 2007 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2932944
27 April 2007 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2916005
23 June 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2687969
13 May 2006 Ballast Water Examination · COC-TVE Renew · MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2638429
10 April 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2327043
16 November 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2242325
15 November 2004 COC-TVE Renew · ISPS II Exam
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2240028
14 May 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1793858
14 May 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1809002
12 March 2003 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1756159
11 February 2002 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1485462
5 December 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 296007
7 February 2001 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1059526
4 February 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 286582
18 August 2000 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 281067
7 July 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 767003
6 July 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 189388
30 May 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 278182
17 March 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 275673
4 February 2000 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 274507
3 February 2000 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 273669
8 November 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 423282

Deficiency record · 17

Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 13 May 2006 Resolved
Repair bridge steering gear alarms. When tested, loss of power and low hydraulic oil level alarms for both pumps would not sound on bridge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2006
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 13 May 2006 Resolved
Make pumproom available for inspection. Provide marine chemist report attesting that pumproom is gas free.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2006
Resolution: Marine chemist certificate was provided.
Communications › Alarms/Indicators
Issued 12 March 2003 Resolved
Tank overfill alarm has no visible and poor audible indcations (very hard to hear forward and amidship) as required by 46 CFR 39.20-7(d)(2) and 33 CFR 155.480(b)(2). Class to attest to proper operation prior to vessel loading in the U.S. or 30 days, whichever is less. LEGACY COMPONENT DESC: Overfill Alarm
Action required: 705 - Other - as specified
Due 12 April 2003
Resolved 12 March 2003
Resolution: Discrepancy corrected by ship''s personnel. ABS attested to proper operation of alarm light and audible signal.
Deck/Cargo › Holds/Tanks
Issued 12 March 2003 Resolved
Vacuum strip tank in cargo pump room leaking oil. All vessel pump rooms shall be free of vapor ignition sources. Class to attest to proper repair of leak in cargo pump room and provide solution to maintain lack of cargo/fuel vapor in pump room by way of stopping ingress of oil. LEGACY COMPONENT DESC: Independent Tank
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2003
Resolution: Received class report from ABS stating that vacuum strip tank pump is operationally satisfactory and is operating IAW manufacturer''''s drawings.
Operations/Management › Equipment Service/Testing
Issued 12 March 2003 Resolved
Proper Span Gas for calibration of oxygen detection equipment not on board the vessel. As required by Solas 74 Ammended, Ch. II-2, Reg.62.18. Correct prior to next U.S. port. LEGACY COMPONENT DESC: Oxygen Testing Equipment
Action required: 15 - Rectify deficiencies by next port
Resolved 12 March 2003
Resolution: Provided proper span gas on board vessel prior to Inspectors departure from vessel.
Lifesaving › Lifeboat
Issued 12 March 2003 Resolved
Water Curtain on Port side lifeboat not working properly. Show proper operation as required by Solas 74 Ammended, Ch. III, Reg. 46.2.1. Correct prior to departure from port. LEGACY COMPONENT DESC: Fire Protection (water spray system)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2003
Resolution: ABS attests to proper operation of port lifeboat water curtain.
Deck/Cargo
Issued 30 May 2000 Resolved
LEAKING HYDRAULIC CONTROL LINE
Condition: Unknown
Due 20 August 2000
Resolved 20 August 2000
Lifesaving
Issued 3 February 2000 Resolved
Prior to departure from St. Croix, USVI, make repairs to the stbd lifeboat on the port side forward where patched.
Condition: Unknown
Due 2 March 2000
Resolved 5 February 2000
Construction/Loadline
Issued 3 February 2000 Resolved
Make repairs to the satisfaction of class society to hull in the 4th bay fwd of the aft access ladder at the turn of the bilge in number four starboard ballast tank.
Condition: Unknown
Due 2 March 2000
Resolved 4 February 2000
Fire Fighting
Issued 3 February 2000 Resolved
Prior to conducting cargo operations, conduct test to the fire hoses to thesatisfaction of the class society and the attending CG Marine Inspector.
Condition: Unknown
Due 2 March 2000
Resolved 5 February 2000
Construction/Loadline
Issued 3 February 2000 Resolved
Make repairs to the satisfacton of the class society to the soft patch in the forward bulkhead of the cargo pump room in the vicinity of valve 594 onthe lower level.
Condition: Unknown
Due 2 March 2000
Resolved 4 February 2000
Fire Fighting
Issued 3 February 2000 Resolved
Prior to conduction cargo operations, make repairs to the number one fire pump cooling line.
Condition: Unknown
Due 2 March 2000
Resolved 4 February 2000
Lifesaving
Issued 3 February 2000 Resolved
Prior to departure from St. Croix, USVI renew hydrostatic releases.
Condition: Unknown
Due 2 March 2000
Resolved 5 February 2000
Deck/Cargo
Issued 3 February 2000 Resolved
Provide evidence vapor control system meets 46 CFR 39.10-13.c prior to its use.
Condition: Unknown
Due 20 August 2000
Resolved 20 August 2000
Fire Fighting
Issued 3 February 2000 Resolved
Modify fire main system iaw class society approved plan.
Condition: Unknown
Due 20 August 2000
Resolved 20 August 2000
Fire Fighting
Issued 3 February 2000 Resolved
Submit for approval to class society modification plan to the fire main system iaw SOLAS Chapter II-2 reg 4.3.5.(relief valve).
Condition: Unknown
Due 20 August 2000
Resolved 20 August 2000
Construction/Loadline
Issued 3 February 2000 Resolved
Make permanent repairs to the satisfaction of the class society to hull in the number four stbd ballast tank at the turn of the bilge in the vicinty of frame 85.
Condition: Unknown
Due 6 February 2001
Resolved 3 December 2001

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.